CF-Justice Center-LR061013 Concrete Compression Test Report eM J ENGINEERING, INC. 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817) 589-9993 Client: Project: Harrison, Walker, & Harper Police and Fire Renovation City of Coppel! Report Distribution: (1) Harrison, Walker, & Harper (1) City of Coppell (1) Brinkley Sargent Architects (1) Structural Engenuity (1) Teague, Nail, & Perkins (1) City of CoppelJ CMJ Report No.: 875-6111-036 Report Date: 10/13/2006 Strength Slump Air Content Concrete Temperature Ambient Temperature 4000 psi @ 28 Days 3 in min 5 in max 4 % min 6 % max 550 F min 950 F max n/a Placement Date Sampled By Weather Supplier/Mix Air Content Method Test Data 1 0/04/2006 Richard Jones Clear/Light Wind Redi Mixl728 ASTM C231 Specifications Ticket Number: 177223 Time Batched: 10:50 Slump: 5in Air Content: 4.3% Concrete Temperature: 860 F Ambient Temperature: 890 F Placement Location: Paving: Entire Parking Addition Time Sampled: 11 :30 Unit Weight: N/A Yardage (c.y.): 20 of 250 Sample Location: 20' West, 10' North from Southeast Corner of Pavement Concrete Compression Test Results Set # Cylinder Age Max Load Area # Test Date (days) (Ibs. force) (sq.in.) 01 CPF10040601 10/11/2006 7 89340 27.99 01 CPF10040602 11/01/2006 28 01 CPF10040603 11/01/2006 28 01 CPF10040604 Hold Stren,gth (pSI) 3190 Fracture Type E-columnar Normal cylinder size: 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. 10 Gallons of Water Added On-Site, approved by: Dan Young CMJ Engineering, In LIMITATIONS: The test results presented in this report apply only to the specific samples, ite , and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity. Our reports are pr. duced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written en nt of our client and CMJ Engineering, Inc. 01 Page I of 4 Concrete Compression Test Report eM J ENGINEERING, INe. 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817) 589-9993 Client: Project: Harrison, Walker, & Harper Police and Fire Renovation City of Coppel! Report Distribution: (1) Harrison, Walker, & Harper (1) City of Coppell (1) Brinkley Sargent Architects (1) Structural Engenuity (1) Teague, Nail, & Perkins (1) City of Coppell CMJ Report No.: 875-6111-036 Report Date: 10/13/2006 Strength Slump Air Content Concrete Temperature Ambient Temperature Specifications 4000 psi @ 28 Days 3 in min 5 in max Test Data 4 % min 6 % max 550 F min 950 F max n/a Placement Date Sampled By Weather Supplier/Mix Air Content Method 1 0/04/2006 Richard Jones Clear/Light Wind Redi Mixl728 ASTM C231 Ticket Number: 177235 Time Batched: 11:50 Slump: 5in Air Content: 4.2% Concrete Temperature: 920 F Ambient Temperature: 90' F Placement Location: Paving: Entire Parking Addition Time Sampled: 12:40 Unit Weight: N/A Yardage (c.y.): 110 of 250 Sample Location: 50' North, 5' West from Southeast Comer Concrete Compression Test Results Set # Cylinder Age Max Load Area # Test Date (days) (Ibs. force) (sq.in.) 02 CPF10040605 10/11/2006 7 96060 27.99 02 CPF10040606 11/01/2006 28 02 CPF10040607 11/01/2006 28 02 CPF10040608 Hold Stren,gth (pSI) 3430 Fracture Type E-columnar Normal cylinder size: 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. 10 Gallons of Water Added On-Site, approved by: Dan Young CMJ Engineering, Inc R. Carl Lee, S.E. . Vice President/CMT Manager LIMITATIONS: The test results presented in this report apply only to the specific samples, items, and a as described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity. Our reports are produced lely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of out client and CMJ Engineering, Inc. 01 Page 2 of 4 Concrete Compression Test Report eM J ENGINEERING, INe. 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817) 589-9993 Client: Project: Harrison, Walker, & Harper Police and Fire Renovation City of Coppel! Report Distribution: (1) Harrison, Walker, & Harper (1) City of Coppell (1) Brinkley Sargent Architects (1) Structural Engenuity (1) Teague, Nail, & Perkins (1) City of Coppell CMJ Report No.: 875-6111-036 Report Date: 10/13/2006 Strength Slump Air Content Concrete Temperature Ambient Temperature Specifications 4000 psi @ 28 Days 3 in min 5 in max 4 % min 6 % max Test Data 550 F min 950 F max n/a Placement Date Sampled By Weather Supplier/Mix Air Content Method 10/04/2006 Richard Jones Clear/Light Wind Redi Mixl728 ASTM C231 Ticket Number: Slump: Concrete Temperature: Placement Location: 177249 4.75 in 950 F Paving: Time Batched: Air Content: Ambient Temperature: Entire Parking Addition 12:49 4.2% 930 F Time Sampled: 13:45 Unit Weight: N/A Yardage (c.y.): 210 of 250 Sample Location: 10' West, 60' South from Northeast Corner Concrete Compression Test Results Cylinder Age Max Load Area Set # # Test Date (days) (Ibs. force) (sq.in.) 03 CPF10040609 10/11/2006 7 97120 27.99 03 CPF1 004061 0 11/01/2006 28 03 CPF10040611 11/01/2006 28 03 CPF10040612 Hold Stren,gth (pSI) 3470 Fracture Type C-cone/shear No~al cylinder size: 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. 10 Gallons of Water Added On-Site, approved by: Dan Young CMJ Engineering, I c LIMITATIONS: The test results presented in this report apply only to the specific sam les, i ms, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity. Our repo a produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the writt n onsent of our client and CMJ Engineering, Inc. 01 Page 3 of 4 Concrete Compression Test Report eM J ENGINEERING, INC. 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817) 589-9993 Client: Project: Harrison, Walker, & Harper Police and Fire Renovation City of Cappel! Report Distribution: (1) Harrison, Walker, & Harper (1) City of Coppell (1) Brinkley Sargent Architects (1) Structural Engenuity (1) Teague, Nail, & Perkins (1) City of Coppell CMJ Report No.: 875-6111-036 Report Date: 10/13/2006 n/a Placement Date Sampled By Weather Supplier/Mix Air Content Method Test Data 1 0/04/2006 Richard Jones Clear/Light Wind Redi Mixl728 ASTM C231 Strength Slump Air Content Concrete Temperature Ambient Temperature Specifications 4000 psi @ 28 Days 3 in min 5 in max 4 % min 6 % max 550 F min 950 F max Ticket Number: 177263 Time Batched: 14:39 Slump: 5in Air Content: 4.3% Concrete Temperature: 940 F Ambient Temperature: 930 F Placement Location: Paving: Entire Parking Addition Time Sampled: 15:10 Unit Weight: N/A Yardage (c.y.): 310 of 330 Sample Location: 10' South, 5' East from Northwest Corner Concrete Compression Test Results Cylinder Age Max Load Area Set # # Test Date (days) (Ibs. force) (sq.in.) 04 CPF10040613 10/11/2006 7 96000 27.99 04 CPF10040614 11/01/2006 28 04 CPF10040615 11/01/2006 28 04 CPF 1 0040616 Hold Stren,gth (pSI) 3430 Fracture Type C-cone/shear Normal cylinder size: 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. o Gallons of Water Added On-Site LIMITATIONS: The test results presented in this report apply only to the specific sam es, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity. Our repo s are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the wr' en consent of our client and CMJ Engineering, Inc. 01 Page 4 of 4