PA9901-CS060801c Ar "1111116 1341 West Mockingbird Lane DalI as, Texas 75247 972.647.6700 - www.Ixi.com August 1, 2006 JRJ Paving Company P.O. Box 2136 2277 N. Marsch Branch Road Denton TX Attn: Mr. Marty Murphy RE: Wagonwheel Park - Coppell Mix Code Numbers 8272, 8274 The attached concrete mix designs utilizing the appropriate ASTM C -33 or ASTM C -330 aggregate are proposed for use on the above referenced project for ready -mixed concrete to be furnished by TXI. To ensure that the correct mix is delivered to your project, please order by the mix design number which appears in the left hand corner of the mix design. TXI certifies that the above mix designs, when ordered by specified design identity, and delivered by TXI, will meet or exceed the indicated design strength at the designated age when tested in accordance with the applicable and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable provisions of C 94, and evaluated in accordance with applicable provisions of the ACI building code. TXI would like to be included on your mailing list to receive all test reports. ASTM C 94 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. Contact us if you have any questions or require any additional information. Please notify TXI of approval of the proposed mix design prior to its use. Failure to notify us prior to first placement shall constitute acceptance. To ensure that the proper mix design is ordered, please send a copy of this letter, after approval, to the above referenced project to be used by the person ordering the concrete for this job. The information contained in this submittal is confidential and the exclusive property of TXI. It cannot be copied, duplicated or disclosed to third parties without the expressed written consent of TXI. Sincerely, TXI Operations, LP Victor H. Villarreal Manager - Q.A. /Q.C. 1992 - 2006 Digital Site Systems, Inc. Paget Quadrel iService SM GENERAL NOTES Pumping Notes: 1. 5" minimum diameter lines with no reduction to smaller lines. 2. Keep rubber hose to absolute minimum length and plan pipe with as few 90 degree angles as possible. 3. Samples for slump and strength tests should be taken at discharge end of hose for strength guarantee to be valid. 4. To prime pump lines, a minimum of 8.0 sack grout is recommended for lubrication. In the case of strength concrete, equivalent strength grout should be used if the grout remains in the placement. 5. Pump mixes are based on minimum cement content pumped at ground level. As pump line increases in length or height and/or layout configuration changes, mix design modifications may be required to assure strength and pumpability at additional cost to the contractor. 6. TXI cannot control, and is therefore not responsible for excessive loss of entrained air content when loss occurs as a result of boom configuration or free fall discharge from hose. To ensure minimum air loss when pumping, maintain a continuous flow of concrete through the entire length of pipe and do not subject concrete to free fall. 7. The term "pumpable concrete refers to concrete which is capable of being transported through an apparatus which forces concrete to the placing position through a pipeline or hose as long as the recommendations indicated above are followed. The term " pumpable concrete" does not relate to concrete proportioned in a particular manner or containing a specific type of product. Strength of lightweight mix designs valid provided strength specimens are air cured in accordance with ASTM Test Method C 567 -05, section 7.3 except as modified in section 8. 1, alternative method, ASTM Specification C 330 -04. Unless otherwise indicated, when the concrete temperature at point of placement exceeds 90 degrees Fahrenheit, TXI will guarantee the strength performance of the mix design(s) herein submitted up to a maximum placement temperature of 100 degrees Fahrenheit using an ASTM C 494 Type D retarding water- reducer, as long as the concrete is placed within 75 minutes from batch time. Unless otherwise indicated, strength of plain concrete guaranteed up to a maximum placement temperature of 85 degrees Fahrenheit. We are enclosing all available back up data for the referenced mix design(s). If the strength information is not available, or is insufficient, confirmation tests may have to be conducted by your laboratory. 1992 - 2006 Digital Site Systems, Inc. Page3 Quadrel iService SM TXI PROPRIETARY AND CONFIDENTIAL 1341 Mockingbird Lane, Dallas, Texas 75247 www.txi.com Customer: JRJ Paving Company Project: Wagonwheel Park - Coppell Plant: 121 - McKinnev Date Issued: August 1, 2006 8272 5.00SK ADMIX /AEA 1 "CS Class "A" Sidewalks Description Admix. Weight (Ib) Type I /II Cement 1 " - #4 Crushed Stone 470 1882 Concrete Sand 1352 City Water 258 Daravair 1000 2.4 oz. WRDA with Hycol 16 oz. Specified F'c : 3,000 psi @ 28 days TOTAL 3962 Specified Slump: 3.00 To 5.00 in. Designed Unit Weight: 146.7 lbs. /cu.ft. Specified Air: 3.00 To 6.00 % Designed W/C + P Ratio: 0.55 Designed Air: 4.5% Designed Volume: 27.00 cu.ft_ NOTES: TXI has no knowledge or authority regarding where this mix is to be placed (if other than the defined use on page 1), therefore it is the responsibility of the project arch itect/engineer, and or contractor to insure that the above designed mix parameters of compressive strength, water cement ratio, cement content, and air content, are appropriate for the anticipated environmental conditions (ie. ACI -318 sections 4.1 -4.3, and the local Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and Section 1.6.3., and per ASTM C -31. Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the right to adjust these dosages to meet the changes in jobsite demands. This mix has been designed to meet the requirements of the documents received from the project, and /or your verbal request. Aggregate weights may change depending on gradations or specific gravity of material. Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI. Any use or dissemination without permission is a violation of federal criminal law. COMMENTS: 1992 - 2006 Digital Site Systems, Inc. Page4 Quadrel i$ervice SM tX 1341 Mockingbird Lane, Dallas, Texas 75247 (972) 647 -6700, w ,txi.com Date: 8/1/2006 Units: US Mix Name: 8272 1992 - 2006 Digital Site Systems, Inc. Pages Quadrel iService SM STRENGTH SUMMARY, Compression 6" x 12" Strengths No. Of Avg Avg Avg 28 Avg Acc ACI318 Accept Std Tests --------------------------------------------------------------------------- Slump Air Day Age Req'd Age Dev 30 4.97 4.69 4260 4260 3740 28 530 DETAILED STRENGTH, Compression 6" x 12" Batch Date Plant Slump Air Strengths Acc Acc Age Number -------------------------------------------------------------------------------- 28 Day Acc Age Age Run Avg 3 235593 4/11/2006 124 3.00 3.00 5440 5440 28 237703 4/13/2006 140 5.00 4.50 3690 3690 28 238196 4/14/2006 124 3.25 5.60 4870 4870 28 4670 239297 4/17/2006 124 4.75 5.00 4570 4570 28 4370 239429 4/17/2006 124 5.50 5.20 4020 4020 28 4480 239238 4/17/2006 124 5.00 4.70 4500 4500 28 4360 239796 4/18/2006 124 5.00 5.20 4730 4730 28 4410 240866 4/19/2006 140 4.25 4.50 3560 3560 28 4260 241398 4/21/2006 124 5.00 4.60 3960 3960 28 4080 241867 4/24/2006 131 4.50 3.10 3620 3620 28 3710 242604 4/25/2006 124 4.00 4.70 5150 5150 28 4240 242995 4/25/2006 131 5.50 4.00 4190 4190 28 4320 245366 4/28/2006 124 4.25 2.00 5170 5170 28 4840 246503 5/2/2006 124 5.75 6.60 3830 3830 28 4400 247140 5/3/2006 124 5.00 4.60 4210 4210 28 4400 248820 5/8/2006 124 5.75 6.80 3570 3570 28 3870 250078 5/9/2006 146 4.00 5.00 4630 4630 28 4140 257708 5/22/2006 124 7.50 4.90 3590 3590 28 3930 258806 5/24/2006 124 5.25 5.90 3850 3850 28 4020 259177 5/24/2006 131 6.50 3.60 4010 4010 28 3820 265800 6/6/2006 143 4.50 5.70 4450 4450 28 4100 265927 6/6/2006 143 4.25 5.50 4200 4200 28 4220 265658 6/6/2006 150 5.00 4.90 4720 4720 28 4450 265816 6/6/2006 150 5.75 5.10 4170 4170 28 4360 265723 61612006 150 4.50 4.70 5070 5070 28 4650 270489 6/14/2006 150 4.75 3.20 3830 3830 28 4350 270661 6/14/2006 150 5.00 4.50 4260 4260 28 4390 270839 6/14/2006 150 4.75 4.40 4190 4190 28 4090 272829 6/19/2006 150 5.75 5.10 3660 3660 28 4040 273948 6/20/2006 140 6.25 4.10 3990 3990 28 3940 1992 - 2006 Digital Site Systems, Inc. Pages Quadrel iService SM TXI PROPRIETARY AND CONFIDENTIAL 1341 Mockingbird Lane, Dallas, Texas 75247 (972) 647 -6700, www.tx.com Customer: JRJ Paving Company Date Issued: August 1, 2006 Project: Wagonwheel Park - Coppell Plant: 121 - McKinnev 8274 6.00SK ADMIX/AEA 1 "CS Class "C" Hand Placed Paving Description Admix. Weight (Ib) Type 1 /11 Cement 564 1 " - #4 Crushed Stone 1882 Concrete Sand 1273 City Water 258 Daravair 1000 2.8 oz. WRDA with Hycol 20 oz. Specified F'c : 3,600 psi @ 28 days TOTAL 3976 Specified Slump: 3.00 To 5.00 in. Designed Unit Weight: 147.3 lbs. /cu.ft. Specified Air: 3.00 To 6.00 % Designed W/C + P Ratio: 0.46 Designed Air: 4.5 % Designed Volume: 27.00 cu.ft. NOTES: TXI has no knowledge or authority regarding where this mix is to be placed (if other than the defined use on page 1), therefore it is the responsibility of the project architect/engineer, and or contractor to insure that the above designed mix parameters of compressive strength, water cement ratio, cement content, and air content, are appropriate for the anticipated environmental conditions (ie. ACI -318 sections 4.1 -4.3, and the local Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and Section 1.6.3., and per ASTM C -31. Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the right to adjust these dosages to meet the changes in jobsite demands. This mix has been designed to meet the requirements of the documents received from the project, and /or your verbal request. Aggregate weights may change depending on gradations or specific gravity of material. Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI. Any use or dissemination without permission is a violation of federal criminal law. COMMENTS: 1992 - 2006 Digital Site Systems, Inc. Page6 Quadrel iService SM fX 1341 Mockingbird Lane, Da0as, Texas 75247 (972) 647 -6700, www.txi.com Date: 8/1/2006 Units: US Mix Name: 8274 1992 - 2006 Digital Site Systems, Inc. Pagel Quadrel iService SM STRENGTH SUMMARY, Compression 6" x 12" Strengths No. Of Avg Avg Avg 28 Avg Acc AC1318 Accept Std Tests --------------------------------------------------------------------------- Slump Air Day Age Req'd Age Dev 30 4.60 4.40 5240 5240 4620 28 650 DETAILED STRENGTH, Compression 6" x 12" Batch Date Plant Slump Air Strengths Acc Acc Age Number 28 Day Acc Age Age Run Avg 3 173006 12/16/2005 150 3.00 6420 6420 28 --- - - - - -- 173024 12/16/2005 150 3.25 6170 6170 28 174079 12/19/2005 150 2.00 3.20 6200 6200 28 6260 174292 12/21/2005 146 6.00 5.80 5540 5540 28 5970 175973 12/22/2005 146 4.25 4.30 5620 5620 28 5780 182704 1/6/2006 146 5.50 3.90 5440 5440 28 5530 185712 1/11/2006 145 3.50 4.00 4770 4770 28 5270 188865 1/17/2006 146 4.00 5.00 5920 5920 28 5380 189739 1/18/2006 146 4.00 5.40 5580 5580 28 5420 189691 1/23/2006 131 4.00 5100 5100 28 5530 193600 1/24/2006 146 5.00 5.80 4960 4960 28 5210 196257 1/27/2006 123 5.75 3.90 4460 4460 28 4840 197758 1/31/2006 146 5.50 5.50 4610 4610 28 4670 198571 2/1/2006 146 7.00 5.70 4750 4750 28 4610 199401 2/2/2006 146 4.00 5.00 5400 5400 28 4920 217341 3/8/2006 144 3.00 4.40 5400 5400 28 5180 223489 3/20/2006 131 5.50 4710 4710 28 5170 227028 3/27/2006 131 5.75 3.90 6810 6810 28 5640 226718 3/27/2006 131 5.25 5.70 5570 5570 28 5700 229653 3/31/2006 131 4.50 4.00 4610 4610 28 5660 252575 5/12/2006 140 5.00 3.00 4420 4420 28 4870 252398 5/12/2006 147 5.00 4.40 5780 5780 28 4940 253017 5/16/2006 140 4.00 3.40 4310 4310 28 4840 256358 5/18/2006 120 3.00 3.50 4850 4850 28 4980 255932 5/18/2006 123 6.25 5.40 4770 4770 28 4640 256409 5/18/2006 140 4510 4510 28 4710 256656 5/19/2006 140 3.75 2.00 4700 4700 28 4660 261265 5/26/2006 146 5.00 4.60 5400 5400 28 4870 276468 6/23/2006 150 3.75 3.70 5510 5510 28 5200 134149 10/11/2006 131 7.00 4.40 4950 4950 28 5290 1992 - 2006 Digital Site Systems, Inc. Pagel Quadrel iService SM Grace Construction Products W.R. Grace & Co. - Conn. 4323 Crites Street Houston, TX 77003 713 - 223 -8353 www.graceconstruction.com 6/15/2005 Victor H. Villarreal TXI Operations, Lp 1341 W. Mockingbird Lane Dallas, Texas 75247 Project Name: All Projects Product Selected: Daravair® 1000 This is to certify that the Daravair® 1000, a(n) Air - Entraining Agent, as manufactured and supplied by Grace Construction Products, W.R. Grace & Co. - Conn., is formulated to comply with the Specifications for Chemical Admixtures for Concrete, ASTM: C260 AASHTO: M154. Daravair® 1000 does not contain calcium chloride or chloride containing compounds as a functional ingredient. Chloride ions may be present in trace amounts contributed from the process water used in manufacturing. The foregoing is in addition to and not in substitution for our standard Conditions of Sale attached. Thomas M. Greene South Western Region Technical Services Manager Grace Construction Products W.R. Grace & Co. - Conn. 4323 Crites Street Houston, TX 77003 713 - 223 -8353 www.graceconstruction.com 6/15/2005 Victor H. Villarreal TXI Operations, Lp 1341 W. Mockingbird Lane Dallas, Texas 75247 Project Name: All Projects Product Selected: WRDA® with Hycol® This is to certify that the WRDA® with Hycol®, a(n) Water Reducer, as manufactured and supplied by Grace Construction Products, W.R. Grace & Co. - Conn., is formulated to comply with the Specifications for Chemical Admixtures for Concrete, ASTM: C494, Type A, D AASHTO: M194, Type A, D. WRDA® with Hycol® does not contain calcium chloride or chloride containing compounds as a functional ingredient. Chloride ions may be present in trace amounts contributed from the process water used in manufacturing. The foregoing is in addition to and not in substitution for our standard Conditions of Sale attached. Thomas M. Greene South Western Region Technical Services Manager MIDLOTHIAN CEMENT 245 Ward Road - Midlothian, Texas 76065 Sin Number Car Number: Sample Date: May -2006 Monthly Average SPECIFICATIONS Portland Cement Type 1 /11 (Low Alkali) A.S.T.M C150 -04 * *Not Applicable. Jeff Wendel, Quality Services Manager NSF Certified to NSF /ANSI 61 Spec. Test Spec. Test Chemical Requirements: Limit Result Physical Requirements: Limit Result Air Content, Volume, ( %) 12 max 8 Al203, ( %) 6.0 max 4.3 Fineness (Blaine), (m2 /kg) 280 min 345 Fe203, ( %) 6.0 max 3.8 Autoclave Expansion, ( %) 0.80 max -0.01 MgO, ( %) 6.0 max 1.4 Time of Setting: S03,(%) 3.0 max 2.7 Vicat initial set, minutes 0.80 max 104 Loss on Ignition, ( %) 3.0 max 2.2 375 max 104 insoluble Residue, ( %) 0.75 max 0.27 Gillmore initial set, (minutes) 60 min 177 C3A, ( %) 8 max 5 Gillmore final set, (minutes) 600 max 285 CO2, ( %) ** 1.0 Limestone, ( %) 5.0 max 2.4 Compressive strengths, (Mpa) CaCO3 in limestone, ( %) 70 min 96 3 days 7.0 min 26.7 7 days 12.0 min 32.6 Spec. Test Compressive strengths, (psi) Optional Chemical Requirements: Limit Result 3 days 1740 min 3875 Total Alkalies (Na20 equiv.), ( %) 0.60 max 0.51 7 days 2760 min 4732 * *Not Applicable. Jeff Wendel, Quality Services Manager NSF Certified to NSF /ANSI 61 TXI Corp. Bell's Savoy Sand Pit. DATE July 14, 2006 COMPANY / NAME Sherry Pulliam MATERIAL Concrete Sand ASTM C - 33 FINE AGGREGATE TEST RESULTS SIEVE SIZE WT. RETAINED % PASSING SPECIFICATION U. METRIC 3/8" 9.5mm 0.0 100.0% 100 #4 4.75mm 34.8 95.7% 95 100 #8 2.36mm 98.2 87.8% 80 100 #16 1.18mm 170.7 78.8% 50 85 #30 .600mm 338.1 58.0% 25 60 #50 .300mm 677.9 15.7% 5 30 #100 .150mm 797.0 0.9% 0 10 #200 .075mm 803.3 0.1% 0 3 TOTAL WEIGHT 804.5 SPECIFIC TEST RESULTS SPECIFIC GRAVITY 2.63 UNIT WEIGHT: ABSORPTION 0.6 DRY LOOSE 104.2 DRY RODDED 110.5 LB./ CF. L A ABRASION N/A SE 91 SODIUM SOUNDNESS 1 MAGNESIUM SOUNDNESS 6 Skeet Caruthers TXI REPRESENTATIVE TXI Corp. Mill Creek TECHNICAL SERVICES LAB PHONE: 972 -647 -7232 FAX: 972 -647 -7244 I ��AAIAiIIAIll AA6` AAAAAitlA3Atl�lAAf1AA lAAL"Alltl!!R�!AAA!AIAy;�isA! AAA! AiAtltl �l �gdAAll pAAiAAAAIiI!! �!l AAl �l tlAtlEA4s�HAlAAi' tlAAAAIA( AMaAA�I 1plAlitl�AAA3AlRAi1MiAA;AAI�IC DATE May 18, 2006 COMPANY /NAME MATERIAL 1" - #4 CLASS A TxDOT ITEM 421 GRADE 4 A; II�tliAA ltl�i{A;AffiAIAIF�IIII�I�IAA 'A!AlAA3lltliAtlIMA�AAIItliiAtlAtl �N��i�' IAtA' AIIYtlANl 9AANA�AI IIiAAI ptlAAAii�AAfgEA�IAdAA IAtliAi�AANtA4AtAAtl�IAA! TEST RESULTS SIEVE SIZE WT. RETAINED % RETAINED SPECIFICATION U. S. METRIC UNIT WEIGHT: ABSORPTION 0.7 11/2" 37.5mm 0.0 0.0% 0 1 1. 25.Omm 0.3 1.1% 0 5 3/4" 19.0 mm 3.6 12.6% 2 1/2" 12.5mm 16.6 58.2% 40 75 3/8" 9.5mm 23.2 81.4% Skeet Caruthers #4 4.75mm 27.7 97.2% 90 100 #8 2.36mm 28.3 99.3% 95 100 TOTAL WEIGHT 28.5 IIIItl6tlMiItlAtlIIIAtl tltldlAitltlAl A! 6SIEtlAltl!tl�l AAI< Al �Al itli R@ IAAA 1p1�AAItlAIINAIAAIA�I�tAAAANA81 SPECIFIC TEST RESULTS SPECIFIC GRAVITY 2.75 UNIT WEIGHT: ABSORPTION 0.7 DRY LOOSE 91.9 LB./ CF. DRY RODDED 100.9 LB./ CF. LA ABRASION 24 DECANT 0.8 SODIUM SOUNDNESS 2 MAGNESIUM SOUNDNESS 4 9l �IAYtlAIAIAI ARIL AI AAIAtlifiAl ��l liApiltl�lAl Al �tllAl ittl; tlA�tiiAiMillll Al tl�NAtiAiAAptlIFBAi lIl91Ai11IiNAAiA!'�IICIiItl:?Al Atli! Y�AAAAAI A' dtlMl SlfAl 9tliAAAipAIAql Al 411 AAAAIAI�AAArtNNA�iM "AlAlAtlgtliAAAt'I�Atl Skeet Caruthers TXI REPRESENTATIVE