St Ann Catholic-LR070511CONCRETE COMPRESSIVE STRENGTH TEST Irerracon
Report Number: 94061334.0048 -C Zv 8901 Carpenter Frwy, Ste #100
Service Date: March 15, 2007 ^ Dallas, Texas 75247
V (214) 630 -1010
Client: Report Date: May 11, 2007
St Ann Catholic Church Project: St. Ann Catholic Parish
Attn: Jennifer Lindsey New Addition
180 Samuel Blvd 180 Samuel Blvd.
Coppell TX 75019 Coppell, TX
Project No.: 94061334
Material Information
Specified Strength: 4000 psi @ 28 Days
Batch Time: 12:24 PM Plant: 7
Supplier: Lattimore Materials Co.
Truck No: 1125 Ticket No: 7176508
Mix I.D. No.: 1701
Water Added Onsite Before Test: OGallons
Water Added Onsite After Test: 10 Gallons
Field Test Dat
Sample Information
Date Cast: March 15, 2007 Time: 1:10 PM
Sampled by: Polikarp J. Labecki
Weather Conditions: Sunny
Accumulative Yards: 10/10
Placement Method: Direct Discharge
Sample Locations: E curb
Placement Location: Paving, Road between church & new
addition
Test
Result
Specification
Test Metho
Slump, inches:
3.75
-
ASTM C143
Air Content, %:
3.5
-
ASTM C231
Concrete Temperature, OF:
78
-
ASTM C1064
Ambient Temperature, OF'.
77
ASTM C1064
Plastic Unit Weight, pcf:
148.7
ASTM C138
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Area
No. ID (inches) ( sq. inches
Date
Tested
Test Load
(days
Strength
(psi)
1 1 6.00
28.27
03/22/2007
__ jibs )
7 122,220
4,320
1 2 6.00
28.27
04/12/2007
28 142,950
5,060
1 3 6.00
28.27
04/12/2007
28 145,390
5,140
Average (28 Days)
5,100
1 4 6.00
28.27
05/10/2007
56 159,480
5,640
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Terracon Rep: Polikarp J. Labecki
Report Distribution:
(1) St Ann Catholic Church (1) TechniStructures
(1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by:
(1) City of Coppell TX A. Bulent Ethem, P.G. - 7 (1) Page Southerland Page Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 o'_` °wao,.vw,ra kay