Loading...
St Ann Catholic-LR070511CONCRETE COMPRESSIVE STRENGTH TEST Irerracon Report Number: 94061334.0048 -C Zv 8901 Carpenter Frwy, Ste #100 Service Date: March 15, 2007 ^ Dallas, Texas 75247 V (214) 630 -1010 Client: Report Date: May 11, 2007 St Ann Catholic Church Project: St. Ann Catholic Parish Attn: Jennifer Lindsey New Addition 180 Samuel Blvd 180 Samuel Blvd. Coppell TX 75019 Coppell, TX Project No.: 94061334 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 12:24 PM Plant: 7 Supplier: Lattimore Materials Co. Truck No: 1125 Ticket No: 7176508 Mix I.D. No.: 1701 Water Added Onsite Before Test: OGallons Water Added Onsite After Test: 10 Gallons Field Test Dat Sample Information Date Cast: March 15, 2007 Time: 1:10 PM Sampled by: Polikarp J. Labecki Weather Conditions: Sunny Accumulative Yards: 10/10 Placement Method: Direct Discharge Sample Locations: E curb Placement Location: Paving, Road between church & new addition Test Result Specification Test Metho Slump, inches: 3.75 - ASTM C143 Air Content, %: 3.5 - ASTM C231 Concrete Temperature, OF: 78 - ASTM C1064 Ambient Temperature, OF'. 77 ASTM C1064 Plastic Unit Weight, pcf: 148.7 ASTM C138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area No. ID (inches) ( sq. inches Date Tested Test Load (days Strength (psi) 1 1 6.00 28.27 03/22/2007 __ jibs ) 7 122,220 4,320 1 2 6.00 28.27 04/12/2007 28 142,950 5,060 1 3 6.00 28.27 04/12/2007 28 145,390 5,140 Average (28 Days) 5,100 1 4 6.00 28.27 05/10/2007 56 159,480 5,640 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Polikarp J. Labecki Report Distribution: (1) St Ann Catholic Church (1) TechniStructures (1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by: (1) City of Coppell TX A. Bulent Ethem, P.G. - 7 (1) Page Southerland Page Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 o'_` °wao,.vw,ra kay