Service Star-LR070507 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061329.0115 Service Date: April 6, 2007 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Report Date: May 07, 2007 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Sample Information Date Cast: April 6, 2007 Time: 4:50 AM Sampled by: Barry Cuble Weather Conditions: Cloudy, breeze Accumulative Yards: 30/150 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: 35' S & 65' E of SW corner of Building Placement Location: Pavement, Fire Lane & Parking Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 4:25 AM Plant: 01 Supplier: Nelson Bros. Truck No: 115 Ticket No: 175885 Mix I.D. No.: PD36AEA Water Added Onsite Before Test: 20 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content. %: Concrete Temperature, of: Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 5.50 5.2 66 49 143,2 Specification 3-5 4.5-7.5 Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C1064 ASTM C138 Laboratorv Test Data Age at Maximum Compressive Test Load Strength (days) (Ibs) (psi) 7 103,200 3,650 28 145,410 5,140 28 144,820 5~ Average (28 Days) ~ 4 06/01/2007 56 Services _ Obtain samples of fresh concrete at the placement locations, perform required field tests and Cast compressive strength samples. Set No. 1 1 1 Specimen ID 1 2 3 Diameter Area (inches) (sq. inches) 6.00 28.27 6.00 28.27 6.00 28.27 Date Tested 04/13/2007 05/04/2007 05/04/2007 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 O,_PDRIR01_Fulure Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061329.0115 Service Date: April 6, 2007 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Report Date: May 07, 2007 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Sample Information Date Cast: April 6, 2007 Time: 6:40 AM Sampled by: Barry Cuble Weather Conditions: Cloudy, breeze Accumulative Yards: 140/150 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: 10' S & 30' E of SE corner of Building Placement Location: Pavement, Fire Lane & Parking Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 5:31 AM Plant: 01 Supplier: Nelson Bros. Truck No: 223 Ticket No: 175896 Mix I.D. No.: PD36AEA Water Added Onsite Before Test: 15 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 4.75 5.5 63 49 144.8 Specification 3-5 4.5-7.5 Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C 1064 ASTM C138 Laboratory Test Data Age at Maximum Compressive Date Test Load Strength Tested (days) (Ibs) (psi) 7 120,990 4,280 28 156,640 5,540 28 157,350 5,560 Average (28 Days) 5,550 2 4 06/01/2007 56 Services _ Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Set No. 2 2 2 Specimen 10 1 2 3 Diameter Area (inches) (sq. inches) 6.00 28.27 6.00 28.27 6.00 28.27 04/13/2007 05/04/2007 05/04/2007 Terracon Rep: Barry Cuble Report Distribution: (1) ServiceStar Design Group LLC (1) City of Coppell TX (1) City of Coppell TX (1) ICI Construction Inc (1) ICI Construction Inc (1) Pate Engineers (1) ServiceS tar Design Group LLC (1) Ratliff Group LLC Reviewed by: Lyndon J. x, P.E. Princip E gineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the u of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 01-PDR/R01.Fullle Key