Loading...
Service Star-LR070416 . CONCRETE COMPRESSWE STRENGTH TEST . Report Number: 94061329.0115 Service Date: April 6, 2007 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Report Date: April 16, 2007 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Sample Information Date Cast: April 6, 2007 Time: 4:50 AM Sampled by: Barry Cuble Weather Conditions: Cloudy, breeze Accumulative Yards: 30/150 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: 35' S & 65' E of SW corner of Building Placement Location: Pavement, Fire Lane & Parking Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 4:25 AM Plant: 01 Supplier: Nelson Bros. Truck No: 115 Ticket No: 175885 Mix I.D. No.: PD36AEA Water Added Onsite Before Test: 20 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pcf: Result 5.50 5.2 66 49 143.2 Specification 3-5 4.5-7.5 Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C 1064 ASTM C138 Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 04/13/2007 7 1 2 05/04/2007 28 1 3 05/04/2007 28 1 4 06/01/2007 56 Services _ Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Maximum Compressive Load Strength (Ibs) (psi) 103,200 3,650 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 01-PDRlRD1.Fulure K~JI CO'NCRETE COMPRESSIVE STRENGTH TEST . Report Number: 94061329.0115 Service Date: April 6, 2007 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Report Date: April 16, 2007 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Samole Information Date Cast: April 6, 2007 Time: 6:40 AM Sampled by: Barry Cuble Weather Conditions: Cloudy, breeze Accumulative Yards: 140/150 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: 10' S & 30' E of SE corner of Building Placement Location: Pavement, Fire Lane & Parking Materia/Information Specified Strength: 3500 psi @ 28 Days Batch Time: 5:31 AM Plant: 01 Supplier: Nelson Bros. Truck No: 223 Ticket No: 175896 Mix I.D. No.: PD36AEA Water Added Onsite Before Test: 15 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pct: Result 4.75 5.5 63 49 144.8 Specification 3-5 4,5-7.5 Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C1 064 ASTM C138 Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) 2 1 6.00 28.27 04/13/2007 7 2 2 05/04/2007 28 2 3 05/04/2007 28 2 4 06/01/2007 56 Services _ Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Maximum Compressive Load Strength (Ibs) (psi) 120,990 4,280 Terracon Rep: Barry Cuble Report Distribution: (1) ServiceStar Design Group LLC (1) City of Coppell TX (1) City of Coppell TX (1) ICI Construction Inc (1) ICI Construction Inc (1) Pate Engineers (1) ServiceStar Design Group LLC (1) Ratliff Group LLC Reviewed by: Lyndon J. C x P.E. Principal E g eer The tests were performed in general accordance with applicable ASTM, AASHTO. or DOT test methods, This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 01-POR/R01-Futurfl Key