Loading...
Service Star-LR070604 Age at Maximum Compressive Test Load Strength (days) (Ibs) (psi) 7 103,200 3,650 28 145,410 5,140 28 144,820 5,120 Average (28 Days) 5,130 4 6.00 28.27 06/01/2007 56 165,340 5,850 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061329.0115 Service Date: April 6, 2007 Client: SeNiceStar Design Group L Attn: Frank Malek 5670 Greenwood P Blvd, Suite 300 Greenwood Vii CO 80111 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 4:25 AM Plant: 01 Supplier: Nelson Bros. Truck No: 115 Ticket No: 175885 Mix I.D. No.: PD36AEA Water Added Onsite Before Test: 20Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 5.50 5.2 66 49 143.2 Laboratory Test Data Set No. 1 1 1 Specimen ID 1 2 3 Diameter Area (inches) (sq. inches) 6.00 28.27 6.00 28.27 6.00 28.27 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: June 04, 2007 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Sample Information Date Cast: April 6, 2007 Time: 4:50 AM Sampled by: Barry Cuble Weather Conditions: Cloudy, breeze Accumulative Yards: 30/150 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: 35' S & 65' E of SW corner of Building Placement Location: Pavement, Fire Lane & Parking Specification 3-5 4.5-7.5 Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C 1064 ASTM C138 Date Tested 04/13/2007 05/04/2007 05/04/2007 f'lj~ 6J)1/~~ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 01-PORIR01-Fwe Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061329.0115 Service Date: April 6, 2007 lrerracon 8901 Carpenter Frwy, Ste #1 00 Dallas, Texas 75247 (214) 630-1010 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Report Date: June 04, 2007 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Sample Information Date Cast: April 6, 2007 Time: 6:40 AM Sampled by: Barry Cuble Weather Conditions: Cloudy, breeze Accumulative Yards: 140/150 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: 10' S & 30' E of SE corner of Building Placement Location: Pavement, Fire Lane & Parking Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 5:31 AM Plant: 01 Supplier: Nelson Bros. Truck No: 223 Ticket No: 175896 Mix I.D. No.: PD36AEA Water Added Onsite Before Test: 15 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 4.75 5.5 63 49 144.8 Specification 3-5 4.5-7.5 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C 1064 ASTM C138 Laboratory Test Data Age at Maximum Compressive Test Load Strength (days) (Ibs) (psi) 7 120,990 4,280 28 156,640 5,540 28 157,350 5,560 Average (28 Days) 5,550 2 4 6.00 28.27 06/01/2007 56 167,350 5,920 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Set No. 2 2 2 Specimen 10 1 2 3 Diameter Area (inches) (sq. inches) 6.00 28.27 6.00 28.27 6.00 28.27 Date Tested 04/13/2007 05/04/2007 05/04/2007 Terracon Rep: Barry Cuble Report Distribution: (1) ServiceStar Design Group LLC (1) City of Coppel! TX (1) City of Coppel! TX (1) ICI Construction Inc (1) ICI Construction Inc (1) Pate Engineers (1) ServiceStar Design Group LLC (1) Ratliff Group LLC Reviewed by: Lyndon J.. Princi I The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for th of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 01..pDFlIR01-FlAureKey