Gateway BP(3.1)-LR070525Rone Engineering Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Project: Gateway Business Center Coppell, Texas Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Services: Contractor: Constructors Associates Concrete Supplier: Lattimore Materials Plant: 7 Specification Requirements Strength: 3,600 psi 28 days Slump (in.): NA Air NA Test Method: ASTM C -172 ASTM C -31 (except 10.1.2) ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 Cylinder Marked Date Age Set No. Tested (days) 1 1 04/27/2007 7 1 4 HOLD Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) Diameter (in) 6.00 1 2 05/18/2007 28 6.00 1 3 05/18/2007 28 6.00 Report of Concrete Compressive Strength Test Mix Design 1.D.: 1551 Placement Date: 04/20/2007 Weather Conditions: Clear Time Sampled: 03:OOpm Batch time: 02:18pm Temperature Air: 74 °F Concrete: 74 °F Truck No: 947 Ticket No: 7177689 Air Content: 5.5% Unit Weight (pcf): NA Overall Placement Location: Manhole 6 +11.30, footing 175.00, 0 +18.70, 0 +48.7 Sample Location: Inlet bottom, 6 +11.30 REPORT OF TESTS Area (in') 28.27 28.27 28.27 Report No.: 285452 Project No.: 0712786 Date of Service: 04/20/2007 Report Date: 05/25/2007 119,930 109,870 Average Compressive Strength (psi) 91,710 3,240 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 7704C 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 4,240 3,890 4,060 Measured Slump (inches) 4.5 Fracture Type Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB /KG) Page 1 of 2 Rone Engineering u Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Repo Concrete Compressive Strength Tesi Project: Gatewa siness Center Cop Texas ain samples of fresh concrete at the placemen •.locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testin• accordance with applicable standards. Contractor: Constructors Associates Concrete Supplier: Redi -Mix Concrete Plant: 259 Specification Requirements Strength: Slump (in.): Air Test Method: 3,000 psi 28 days 3.0" 5.0" 0.0% 2.0% ASTM C -172 ASTM C -31 (except 10.1.2) ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 Cylinder Marked Date Age Set No. Tested (days) 1 1 04/19/2007 7 1 2 05/10/2007 28 1 3 05/10/2007 28 Diameter (in) 6.00 PROJECT DATA Mix Design I.D.: 1501 Placement Date: 04/12/2007 Weather Conditions: Clear Time Sampled: 03:30am Temperature Air: 44 °F Truck No: 1179 Air Content: 1.1% Overall Placement Location: Paving Slab Sample Location: 5' E of west end of pad and 25' N of south end of pad REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) Area (in 28.27 72,690 6.00 28.27 108,780 6.00 28.27 109,580 Average 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 7704C 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report No.: 284567 Project No.: 0712786 Date of Service: 04/12/2007 Report Date: 05/25/2007 Batch time: 02:26am Concrete: 66 °F Ticket No: 59005960 Unit Weight (pcf): NA Compressive Strength (psi) 2,570 3,850 3,880 3,860 Measured Slump (inches) 9.0 Fracture Type Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB /KG) Page 1 of 9 Rone Engineering u Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77041 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of Concrete Compressive Strength Test Report No.: 284567 Project No.: 0712786 Date of Service: 04/12/2007 Report Date: 05/25/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in (Ibs) (psi) Type 1 4 HOLD Remarks: Water Added at Site: 10 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB /KG) Page 2 of 9 Rone Engineering Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors Associates Concrete Supplier: Redi -Mix Concrete Plant: 259 Specification Requirements Strength: Slump (in.): Air Test Method: 3,000 psi 28 days 3.0" 5.0" 0.0% 2.0% ASTM C -172 ASTM C -31 (except 10.1.2) ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 Cylinder Marked Date Age Set No. Tested (days) 2 1 04/19/2007 7 2 2 05/10/2007 28 6.00 2 3 05/10/2007 28 6.00 Report of Concrete Compressive Strength Test PROJECT DATA Mix Design I.D.: 1501 Placement Date: 04/12/2007 Weather Conditions: Clear Time Sampled: 04:30am Temperature Air: 41°F Truck No: 1128 Air Content: 1.7% Overall Placement Location: Paving Slab Sample Location: 40' E of west end of pad and 25' N of south end of pad REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) Diameter (in) 6.00 Area (in') 28.27 28.27 28.27 87,410 120,990 119,220 Average 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report No.: 284567 Project No.: 0712786 Date of Service: 04/12/2007 Report Date: 05/25/2007 Batch time: 03:12am Concrete: 67 °F Ticket No: 59005968 Unit Weight (pcf): NA Compressive Strength (psi) 3,090 4,280 4,220 4,250 Measured Slump (inches) 4.5 Fracture Type Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.)- or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB /KG) Page 3 of 9 Rone Engineering MEM VI MUM Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 2 4 HOLD 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of Concrete Compressive Strength Test Report No.: 284567 Project No.: 0712786 Date of Service: 04/12/2007 Report Date: 05/25/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in (Ibs) (psi) Type LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB /KG) Page 4 of 9 Rone Engineering 10 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors Associates Concrete Supplier: Redi -Mix Concrete Plant: 259 Specification Requirements Strength: 3,000 psi 28 days Slump (in.): Air Test Method: 3.0" 5.0" 0.0% 2.0% ASTM C -172 ASTM C -31 (except 10.1.2) ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 Cylinder Marked Date Age Set No. Tested (days) 3 1 04/19/2007 7 Diameter (in) 6.00 3 2 05/10/2007 28 6.00 3 3 05/10/2007 28 6.00 Report of Concrete Compressive Strength Test PROJECT DATA Mix Design I.D.: 1501 Placement Date: 04/12/2007 Weather Conditions: Clear Time Sampled: 05:30am Temperature Air: 39 °F Truck No: 1167 Air Content: 1.7% Overall Placement Location: Paving Slab REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Maximum Area Load (in (Ibs) 28.27 90,980 28.27 119,080 28.27 127,620 Average 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 7704C 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report No.: 284567 Project No.: 0712786 Date of Service: 04/12/2007 Report Date: 05/25/2007 Sample Location: 80' E of west end of pad and 30' N of south end of pad Batch time: 04:31 am Concrete: 63 °F Ticket No: 59005977 Unit Weight (pcf): NA Compressive Strength (psi) 3,220 4,210 4,510 4,360 Measured Slump (inches) 5.0 Fracture Type Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB /KG) Page 5 of 9 Rone Engineering Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of Concrete Compressive Strength Test Report No.: 284567 Project No.: 0712786 Date of Service: 04/12/2007 Report Date: 05/25/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in (Ibs) (psi) Type 3 4 HOLD LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB /KG) Page 6 of 9 Rone Engineering Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors Associates Concrete Supplier: Redi -Mix Concrete Plant: 259 Specification Requirements Strength: 3,000 psi 28 days Slump (in.): 3.0" 5.0" Air 0.0% 2.0% Test Method: ASTM C -172 ASTM C -31 (except 10.1.2) ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 Cylinder Marked Date Age Set No. Tested (days) 4 1 04/19/2007 7 Diameter (in) 6.00 4 2 05/10/2007 28 6.00 4 3 05/10/2007 28 6.00 Report of Concrete Compressive Strength Test PROJECT DATA Mix Design I.D.: 1501 Placement Date: 04/12/2007 Weather Conditions: Clear Time Sampled: 06:30am Temperature Air: 43 °F Truck No: 1179 Air Content: 1.1% Overall Placement Location: Paving Slab Sample Location: 110' E of west end of pad and 10' N of south end of pad REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Maximum Area Load (in (Ibs) 28.27 79,310 28.27 28.27 116,400 121,360 Average 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report No.: 284567 Project No.: 0712786 Date of Service: 04/12/2007 Report Date: 05/25/2007 Batch time: 05:35am Concrete: 66 °F Ticket No: 59005987 Unit Weight (pcf): NA Compressive Strength (psi) 2,810 4,120 4,290 4,200 Measured Slump (inches) 5.5 Fracture Type Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB /KG) Page 7 of 9 Rone Engineering u Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 4 4 HOLD 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 7704C 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of Concrete Compressive Strength Test Report No.: 284567 Project No.: 0712786 Date of Service: 04/12/2007 Report Date: 05/25/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB /KG) Page 8 of 9