Loading...
ST9905-CS070629 Letter of Transmittal 3010 LBJ Freeway, Ste 990 Dallas, TX 75234 T 972-280-9300 F 972-280-9715 (BJ www.transystems.com To: Lance Smith From: Kraus Tiseo Paving P,O. Box 270040 Dallas, Texas 75227-0040 Date: 06-29-07 Su bject: ^_~~~,gE.~~ing~"_'~__"'_~_"_~"'_"H"""'_"'_' "m . Name: Bethel Road/Bass Pro No. of Pages: Project No: 20000089 I 202020089 Handling Instructions: D URGENT!! D For Your Information and Use D As Requested D Please Confirm Receipt D For Review and Comment D For Approval [3J Approved as Submitted D Returned for Corrections D See Comments o Approved as Noted o Rejected o Sent under separate cover via D Shop Drawings D Prints D Specifications D Copy of Letter the following items: D Plans 0 Samples D Copies 2 2 Date Description Mix Design - 6.0 Sack Machine Placed Paving Mix - 6.5 Sack Hand Placed Comments: Deliver Via: C8J Overnight Service (Fed Ex, UPS, DHL) 0 Courier/Messenger CC: ~n O.ifRII, I'.~. (WI I WfJY} - ~ Signature: JQeMgSterSQn,P,I;.(W/J..C.QP~..:l(;A;.~ Print: 1\1i~el3r()~nlf:.~,I"J::::(\V/l.c;gpy). ... ..... ... - y P.O. Box 270040 Dallas, Texas 75227-0040 SUBMITTAL: DATE REC'D ~ AI'PIlOVED. f~ /InstallBtion may be undertaken. Approval does DOt authorize changes ill the CoD1nlct Sum or Contract Time. D APPROVED AS coRREC'l'ED, ,- Fabricrrtion Ilnlitalladllll may be undertaken. Approval ~ not authorize cbqcs ill the Con1nct Sum or Coll1r8Ct Time. D CORRECT. RI:;VISE A.l\lD RES(JBMJT. Flhrieation j lDaIlIllatiOD MAY NOT be UDdert8ken. In ro.::iIlbmitlia&.1iIDit eorrectioos to tile items m8Jbcl. o NO iN TAKEN. :.p;;:;J;ltrKt;c;n~ f - ~ t, BY: ~TE: ~~1 R oYll ftCi+.her catenda IlCIf altcrlllf1 ~ o lpbs of the Enaineer. Review cloe8llOt ~.. comr.ct<< from complyiq with III roquiIemcft1I 01_ ooanct tSocu.mentl. DATE: June 14,2007 TRAN SYSTEMS 3010 LBJ FREEWAY SUITE 900 DALLAS, TX 75234 ATTN: Garry D. Kraus, P.E. PROJECT: BETHEL RD. & BASS PRO DR. TISEO CONCRETE MIX DESIGNS - 6.0 SACK MACHINE PLACED PAVING 6.5 SACK HAND PLACED PAVING PLEASE REVIEW THE SUBMITTAL OR SUBMITTALS AND RETURN -.L COPIES WITH SIGNATURE AND DATE WITH APPROVAL OR REJECTION. '--i I ~L ----------~-~----------------------- LANCE SMITH PROJECT ADMINISTRATOR __~_:~_i~_9..Z______ DATE: &~ 1974 Concrete Mix Design Owner/Customer Project / Location Application Specifications Mix name Concrete mix design data: Tiseo Paving Company Bethel/Bass Pro - CoppeWGrapevine Paving - Machine 3,600 psi 28 Days 6 Sack Machine Placed ))ate: 06/13/07 #Total cementitious material Pounds course agg./eu.yd. % Crushed Limestone Air content (including entrapped air) Gallons water leu. yd. (s.s.d.) One cubic yard weights (55))) Material 5.G. Cement 3.15 Coarse Aggregate 2.72 Fine Aggregate 2.65 Water 1.00 564 Ibs 1950 Ibs 100 % 5.0% 26.0 gallons Volume Cement Crushed Limestone Natural Sand Water Air Entraining Retarding Water-reducer TXI Type lIII Midlothian TXI Dallas Rail 1 W' -#4 Trinity Cottonwood 26 Gallons Pro Mix ProAir 260 Pro Mix Plastimix 100R 2.87 ft? 11.49 ft3 7.82 ft3 3.47 ft3 1.35 ft3 564 Ibs. 1950 Ibs. 1293 Ibs. 217 Ibs. 2 oz. 23 oz. 27.00 ft3 Air Content Slump Range Percent Coarse Aggregate Water Cement Ratio, Lb/Lb Unit Weight, Plastic Concrete 5.0 +/- 1.5% 3 +/- 1 inch 60 % 0.38 149.0 Ibs/ft3 Tiseo Paving Company Air Content Slump Range Percent Coarse Aggregate Water Cement Ratio, Lb/Lb Unit Weight, Plastic Concrete 5.0 +/- 1.5% 4 +/- 1 ineh 62 % 0.37 148.5 Ibs/ft3 Tiseo Paving Company Concrete Mix Design Owner/Customer Project / Location Application Specifications Mix name Concrete mix design data : Tiseo Paving Company BetheIJBass Pro - CoppelVGrapevine Paving - Hand Placed 3,600 psi 28 Days 6'12 Sack Hand Placed Date: 06/13/07 Material S.G. #Total cementitious material Pounds course agg./cu.yd. % Crushed Limestone Air content (including entrapped air) Gallons water leu. yd. (s.s.d.) Cement 3.15 Coarse Aggregate 2.72 Fine Aggregate 2.65 Water 1.00 611 lbs 1950 Ibs 100 % 5.0 % 27.5 gallons One cubic yard weights (SSD) Cement Crushed Limestone Natural Sand Water Air Entraining Retarding Water-reducer Volume TXI Type I/II Midlothian TXI Dallas Rail 1 '12"-#4 Trinity Cottonwood 27.5 Gallons Pro Mix ProAir 260 Pro Mix Plastimix 100R 3.11 ft3 11.49 ft3 7.38 ft3 3.67 ft3 1.3 5 ft3 611 Ibs. 1950 lbs. 1221 Ibs. 229 Ibs. 2 oz. 24 oz. 27.00 ft3 Air Content Slump Range Percent Coarse Aggregate Water Cement Ratio, Lb/Lb Unit Weight, Plastic Concrete 5.0 +/- 1.5% 4 +/- 1 inch 62 % 0.37 148.5 Ibs/ft3 Tiseo Paving Company