Loading...
Duke Lesley-LR070626 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 283826 Project No.: 0612510 Date of Service: 04/05/2007 Report Date: 06/26/2007 Project: Lesley Infrastructure Services: Perform In-Place Density Testing PROJECT DATA Contractor: Test Method: ASTM 0-2922 ASTM 0-3017 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 742 Current: 2632 Previous: 740 Previous: 2629 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements MID No. Description % (pet) Moisture Density 272998 Brown I Silty Clay wi Organics 22.5 96.5 Optimum +4 95 min FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (% max) Utility backfill 12" sanitary sewer, line S-2, Station 12+50, 9' 6" 272998 25.3 114.8 91.6 95 below grade Utility backfill 2 12" sanitary sewer, line S-2, Station 12+50, 8' 6" 272998 25.2 115.4 92.2 96 below grade Utility backfill 3 12" sanitary sewer, line S-2, Station 12+50,7' 6" 272998 26.0 115.2 91.4 95 below grade Utility backfill 4 12" sanitary sewer, line S-2, Station 12+50,6' 6" 272998 24.8 115.2 92.3 96 below grade Utility backfill 5 12" sanitary sewer, line S-2, Station 12+50, 5' 6" 272998 24.1 114.8 92.5 96 below grade Utility backfill 6 12" sanitary sewer, line S-2, Station 12+50,4' 6" 272998 24.7 115.2 92.4 96 below grade LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 283826 Project No.: 0612510 Date of Service: 04/05/2007 Report Date: 06/26/2007 Project: Lesley Infrastructure Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (%max) Utility backfill 7 12" sanitary sewer, line 8-2, Station 12+50, 3' 6" 272998 22.8 115.7 94.2 98 below grade Utility backfill 8 12" sanitary sewer, line 8-2, Station 12+50, 2' 6" 272998 25.5 115.8 92.3 96 below grade Utility backfill 9 12" sanitary sewer, line 8-2, Station 12+50, l' 6" 272998 24.2 116.4 93.7 97 below grade Utility backfill 10 12" sanitary sewer, line 8-2, Station 12+50, 6" 272998 24.8 115.3 92.4 96 final Technician: Joe Jernigan Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Alex Bennett PE (1-ec copy) Started: 09:15am Finished: 11:30am Rone Engineering P-~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 2 of 2 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Project: Lesley Infrastructure Services: Perform In-Place Density Testing 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In-Place Density Testing Report No.: 288279 Project No.: 0612510 Date of Service: OS/22/2007 Report Date: 06/26/2007 PROJECT DATA Contractor: Test Method: ASTM 0-2922 ASTM 0-3017 Gauge: 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 733 Current: 2521 Previous: 730 Previous: 2525 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements % ( pet) Moisture Density 22.5 96.5 Optimum + 95 min FIELD DENSITY TESTS Probe MID Moisture Wet Density Dry Density Density Depth No. % (pet) (pet) (%max) 6" 272998 24.7 117.5 94.2 98 6" 272998 22.9 117.2 95.4 99 6" 272998 24.0 116.3 93.8 97 6" 272998 24.1 116.5 93.9 97 MID No. 272998 Description Brown I Silty Clay wi Organics Test No Test Location Utility backfill Storm line, Drain A, Station 10+00, Final Utility backfill 2 Lot, line A-4, Station 12+75, Final Utility backfill 3 Storm line, Sewer C, Station 5+50, l' below grade Utility backfill 4 Storm line, Sewer C, Station 5+50, Final Technician: Joe Jernigan Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Alex Bennett PE (1-ec copy) Started: 08:45am Finished: 11 :30am Rone Engineering p-~.~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services. Ltd. (TM/LB) Page 1 of 1