Loading...
Duke Lesley-LR070606 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 284057 Project No.: 0612510 Date of Service: 04/06/2007 Report Date: 06/06/2007 Project: Lesley Infrastructure Services: Perform In-Place Density Testing PROJECT DATA Contractor: Test Method: ASTM 0-2922 ASTM D-3017 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 741 Current: 2641 Previous: 742 Previous: 2639 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements MID No. Description % (pet) Moisture Density 272998 Brown I Silty Clay wI Organics 22.5 96.5 Optimum +4 95 min FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (%max) Utility backfill 12" sanitary sewer line S-2, Station 19+00, 9' 6" 272998 25.7 120.3 95.7 99 below grade Utility backfill 2 12" sanitary sewer line S-2, Station 19+00, 8' 6" 272998 25.8 116.2 92.4 96 below grade Utility backfill 3 12" sanitary sewer line S-2, Station 19+00, 7' 6" 272998 23.4 117.8 95.5 99 below grade Utility backfill 4 12" sanitary sewer line S-2, Station 19+00,6' 6" 272998 22.6 117.7 96.0 100 below grade Utility backfill 5 12" sanitary sewer line S-2, Station 19+00, 5' 6" 272998 23.0 117.0 95.1 99 below grade Utility backfill 6 12" sanitary sewer line S-2, Station 19+00, 4' 6" 272998 24.0 116.9 94.3 98 below grade LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 284057 Project No.: 0612510 Date of Service: 04/06/2007 Report Date: 06/06/2007 Project: Lesley Infrastructure Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pcf) (pet) (%max) Utility backfill 7 12" sanitary sewer line S-2, Station 19+00, 3' 6" 272998 24.1 117.3 94.5 98 below grade Utility backfill 8 12" sanitary sewer line S-2, Station 19+00, 2' 6" 272998 22.9 117.1 95.3 99 below grade Utility backfill 9 12" sanitary sewer line S-2, Station 19+90, l' 6" 272998 24.2 117.1 94.3 98 below grade Utility backfill 10 12" sanitary sewer line S-2, Station 19+90, final 6" 272998 24.8 116.9 93.7 97 Technician: Joe Jernigan Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Alex Bennett PE (1-ec copy) Started: 11: 15am Finished: 01 :OOpm Rone Engineering p~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 2 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 284502 Project No.: 0612510 Date of Service: 04/11/2007 Report Date: 06/06/2007 Project: Lesley Infrastructure Services: Perform In-Place Density Testing PROJECT DATA Contractor: Test Method: ASTM D-2922 ASTM D-3017 Gauge: Troxler 3430 Gauge Serial No: 36440 Test Mode: DT Standard Counts Moisture Density Current: 672 Current: 2793 Previous: 677 Previous: 2805 MOISTURE DENSITY RELATIONS MID No. 272998 Description Brown I Silty Clay wI Organics Moisture % Maximum Density (pet) 96.5 Project Requirements Moisture Density Optimum +4 95 min 22.5 Test No Test Location FIELD DENSITY TESTS Probe MID Depth No. Moisture Wet Density Dry Density Density % (pet) (pet) (% max) Utility backfill Water line W-1, Station 0+65, 2' below grade Utility backfill Water line W-1, Station 1 +00, 3' below grade 6" 272998 24.8 116.1 93.0 96 2 6" 272998 24.9 117.3 93.9 97 Technician: Bobby Robinson Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Alex Bennett PE (1-ec copy) Started: 12:45pm Finished: 02:45pm Rone Engineering p~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 1 of 1