Loading...
Duke Lesley-LR070604 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Project: Lesley Infrastructure Services: Perform In-Place Density Testing 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In-Place Density Testing Report No.: 284671 Project No.: 0612510 Date of Service: 04/12/2007 Report Date: 06/04/2007 PROJECT DATA Contractor: Test Method: ASTM 0-2922 ASTM 0-3017 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 742 Current: 2641 Previous: 741 Previous: 2640 MOISTURE DENSITY RELATIONS MID No. 272998 Description Brown I Silty Clay wi Organics Moisture % 22.5 FIELD DENSITY TESTS Maximum Density (pef) 96.5 Project Requirements Moisture Density Optimum +4 95 min Test No Moisture Wet Density Dry Density Density % (pef) (pef) (% maxI Test Location Utility Back Fill Water line, Line W-1, Station 0+65, l' below grade Utility Back Fill Water line, Line W-1, Station 0+65, final Utility Back Fill Water line, Line W-1, Station 1+00, 2' below grade Utility Back Fill Water line, Line W-1, Station 1 +00, l' below grade Utility Back Fill Water line, Line W-1, Station 1 +00, final Utility Back Fill Water line, Line W-1, Station 4+00,3' below grade 2 3 4 5 6 Probe Depth MID No. 24.2 117.1 94.3 98 6" 272998 24.8 116.9 93.7 97 6" 272998 22.8 116.9 95.2 99 6" 272998 24.5 116.2 93.3 97 6" 272998 24.7 116.8 93.7 97 6" 272998 23.6 116.9 94.6 98 6" 272998 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (FB/KW) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 284671 Project No.: 0612510 Date of Service: 04/12/2007 Report Date: 06/04/2007 Project: Lesley Infrastructure Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (% max) Utility Back Fill 7 Water line, Line W-1, Station 4+00,2' below 6" 272998 24.1 117.3 94.5 98 grade Utility Back Fill 8 Water line, Line W-1, Station 4+00, l' below 6" 272998 23.4 117.8 95.5 99 grade Utility Back Fill 9 Water line, Line W-1, Station 4+00, final 6" 272998 24.2 117.1 94.3 98 Utility Back Fill 10 Water line, Line W-1, Station 6+25,3' below 6" 272998 24.1 117.0 94.3 98 grade Utility Back Fill 11 Water line, Line W-1, Station 6+25, 2' below 6" 272998 23.9 117.3 94.7 98 grade Utility Back Fill 12 Water line, Line W-1, Station 6+25, l' below 6" 272998 24.9 116.8 93.5 97 grade Utility Back Fill 13 Water line, Line W-1, Station 6+25, final 6" 272998 23.0 116.5 94.7 98 Technician: Joe Jernigan Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Alex Bennett PE (1-ec copy) Started: 09:30am Finished: 12:00pm Rone Engineering V~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (FB/KW) Page 2 of 2 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Project: Lesley Infrastructure Services: Perform In-Place Density Testing 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In-Place Density Testing Report No.: 284804 Project No.: 0612510 Date of Service: 04/13/2007 Report Date: 06/04/2007 PROJECT DATA Contractor: Test Method: ASTM 0-2922 ASTM 0-3017 Gauge: Troxler 3430 Gauge Serial No: 35009 Test Mode: DT Standard Counts Moisture Density Current: 762 Current: 2417 Previous: 764 Previous: 2419 MOISTURE DENSITY RELATIONS MID No. 272998 Description Brown I Silty Clay wI Organics Moisture % 22.5 FIELD DENSITY TESTS Maximum Density (pef) 96.5 Project Requirements Moisture Density Optimum +4 95 min Test No Moisture Wet Density Dry Density Density % (pet) (pet) (% max) Test Location Utility Back Fill Water line, Line W-1, Station 8+25, 3' below grade Utility Back Fill Water line, Line W-1, Station 8+25, 2' below grade Utility Back Fill Water line, Line W-1, Station 8+25, l' below grade Utility Back Fill Water line, Line W-1, Station 8+25, final Utility Back Fill Latitude line, Line B-5, Station 96+84, final Utility Back Fill Storm drain, Line B, Station 22+50, l' below grade 2 3 4 5 6 Probe Depth MID No. 24.2 116.4 93.7 97 6" 272998 24.8 115.3 92.4 96 6" 272998 25.5 115.8 92.3 96 6" 272998 22.8 115.7 94.2 98 6" 272998 24.7 115.2 92.4 96 6" 272998 24.1 114.8 92.5 96 6" 272998 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (FB/KW) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 284804 Project No.: 0612510 Date of Service: 04/13/2007 Report Date: 06/04/2007 Project: Lesley Infrastructure Services: Perform In-Place Density Testing Test No Test Location Utility Back Fill Storm drain, Line 8, Station 25+40, l' below grade FIELD DENSITY TESTS Probe MID Depth No. Moisture Wet Density Dry Density Density % (pct) (pct) (% max) 7 6" 272998 24.8 115.2 92.3 96 Technician: Joe Jernigan Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Alex Bennett PE (1-ec copy) Started: 08:45am Finished: 10:45am Rone Engineering p~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reprOduced except in full without the written approval of Rone Engineering Services, Ltd. (FB/KW) Page 2 of 2