Duke Lesley-LR070405 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 In-Place Density Testing Report No.: 282733 Project No.: 0612510 Date of Service: 03/23/2007 Report Date: 04/05/2007 Project: Lesley Infrastructure Services: Perform In-Place Density Testing PROJECT DATA Contractor: Test Method: ASTM D-2922 ASTM D-3017 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 741 Current: 2637 Previous: 739 Previous: 2642 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements MID No. Description % (pef) Moisture Density 272998 Brown I Silty Clay wI Organics 22.5 96.5 Optimum +4 95 Minimum FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (% max) Utility backfill 12" sanitary sewer line, S-2, Station 3+50, 9' 272998 24.1 117.5 94.7 98 below grade Utility backfill 2 12" sanitary sewer line, S-2, Station 3+50,8' 272998 22.7 117.4 95.7 99 below grade Utility backfill 3 12" sanitary sewer line, S-2, Station 3+50, 7' 272998 24.2 117.1 94.3 98 below grade Utility backfill 4 12" sanitary sewer line, S-2, Station 3+50, 6' 272998 24.8 116.9 93.7 97 below grade Utility backfill 5 12" sanitary sewer line, S-2, Station 3+50, 5' 272998 23.4 117.8 95.5 99 below grade Utility backfill 6 12" sanitary sewer line, S-2, Station 3+50, 4' 272998 24.1 117.3 94.5 98 below grade LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB/KG) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 In-Place Density Testing Report No.: 282733 Project No.: 0612510 Date of Service: 03/23/2007 Report Date: 04/05/2007 Project: Lesley Infrastructure Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (%max) Utility backfill 7 12" sanitary sewer line, S-2, Station 3+50, 3' 272998 23.6 116.9 94.6 98 below grade Utility backfill 8 12" sanitary sewer line, S-2, Station 3+50, 2' 272998 24.7 116.8 93.7 97 below grade Utility backfill 9 12" sanitary sewer line, S-2, Station 3+50, l' 272998 24.5 116.2 93.3 97 below grade Utility backfill 10 12" sanitary sewer line, S-2, Station 3+50, final 272998 22.8 116.9 95.2 99 Utility backfill 11 Storm drain line 8, Station 14+50,6' below 272998 24.2 117.1 94.3 98 grade Technician: Joe Jernigan Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Alex Bennett PE (1-cc copy) Started: 02:15pm Finished: 04:15pm Rone Engineering p~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB/KG) Page 2 of 2 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Project: Lesley Infrastructure Services: Perform In-Place Density Testing PROJECT DATA 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 In-Place Density Testing Report No.: 282697 Project No.: 0612510 Date of Service: 03/23/2007 Report Date: 04/05/2007 Contractor: Test Method: ASTM 0-2922 ASTM 0-3017 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 741 Current: 2637 Previous: 739 Previous: 2642 MOISTURE DENSITY RELATIONS MID No. 272998 Description Brown I Silty Clay wi Organics Moisture % 22.5 FIELD DENSITY TESTS Maximum Density (pet) 96.5 Project Requirements Moisture Density Optimum +4 95 Minimum Test No Moisture Wet Density Dry Density Density % (pet) (pet) (% max) Test Location Utility bacakfill 12" sanitary sewer line, S-2, Station 4+75,9' below grade Utility bacakfill 12" sanitary sewer line, S-2, Station 4+75, 8' below grade Utility bacakfill 12" sanitary sewer line, S-2, Station 4+75,7' below grade Utility bacakfill 12" sanitary sewer line, S-2, Station 4+75,6' below grade Utility bacakfjll 12" sanitary sewer line, S-2, Station 4+75,5' below grade Utility bacakfill 12" sanitary sewer line, S-2, Station 4+75,4' below grade 2 3 4 5 6 Probe Depth MID No. 23.9 117.0 94.4 98 6" 272998 23.3 117.3 95.1 99 6" 272998 24.9 116.8 93.5 97 6" 272998 23.0 116.5 94.7 98 6" 272998 22.6 117.0 95.4 99 6" 272998 23.5 117.1 94.8 98 6" 272998 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (AB/KG) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 In-Place Density Testing Report No.: 282697 Project No.: 0612510 Date of Service: 03/23/2007 Report Date: 04/05/2007 Project: Lesley Infrastructure Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe MID No Test Location Depth No. Utility bacakfill 7 12" sanitary sewer line, S-2, Station 4+75,3' 6" 272998 below grade Utility bacakfill 8 12" sanitary sewer line, S-2, Station 4+75, 2' 6" 272998 below grade Utility bacakfill 9 12" sanitary sewer line, S-2, Station 4+75, l' 6" 272998 below grade Utility bacakfill 10 12" sanitary sewer line, S-2, Station 4+75, final 6" 272998 Moisture Wet Density Dry Density Density % (pcf) (pet) (% max) 22.9 116.8 95.0 98 24.7 117.7 94.4 98 24.2 117.1 94.3 98 24.1 117.0 94.3 98 Technician: Joe Jernigan Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Alex Bennett PE (1-cc copy) Started: 10:00am Finished: 12:15pm Rone Engineering ~~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responSibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (AB/KG) Page 2 of 2