Loading...
Duke Lesley-LR070220 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W. Little York, Suite 600, Houston, TX 77040 4221 Freidrich Lane, Suite 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 IN-PLACE DENSITY TESTING Client: Duke Construction, LP Mr. Alex Bennett, PE 5495 Belt Line Road, Suite 360 Dallas TX 75254 Report No.: Project No.: Date of Service: Report Date: 277411 0612510 01/31/2007 02/20/2007 Project: Lesley Infrastructure Cappell, Texas Services: Perform In-Place Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: Duke Construction, LP Test Methods: ASTM D-2922 ASTM D-3017 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 740 Current: 2556 Previous: 744 Previous: 2560 MOISTURE DENSITY RELATIONS MID No. Description Moisture % Maximum Density pcf Project Requirements Moisture Density Brown Silty Clay w/Organics 22.5 96.5 Optimum +4 95 min FIELD DENSITY TESTS TEST PROBE MID MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. (%) (pet) (pet) (% max) Fill 1 100' east, 200' south, area F, norhwest 6" 25.6 117.7 93.7 97 comer, l' below grade Fill 2 100' east, 300' south, area F, norhwest 6" 1 26.3 117.8 93.3 97 comer, l' below grade Fill 3 100' east, 400' south, area F, norhwest 6" 25.2 118.1 94.3 98 comer, l' below grade Fill 4 100' east, 500' south, area F, norhwest 6" 24.2 118.1 95.1 99 comer, I' below grade Fill 5 100' east, 600' south, area F, norhwest 6" 24.3 118.0 94.9 98 comer, I' below grade LI1vITrATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 17 Page 1 of 3 . ,_,.~ _. ,~u ._v. ...~ Report No.: 277411 ~ Project No.: 0612510 Client: Duke Construction, LP TEST PROBE MID MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCA nON DEPTH No. (%) (pel) (pel) (% max) Fill 6 200' east, 200' south, area F, norhwest 6" 24.3 117.5 94.5 98 comer, l' below grade Fill 7 200' east, 300' south, area F, norhwest 6" 24.4 117.3 94.3 98 comer, l' below grade Fill 8 200' east, 400' south, area F, norhwest 6" 1 24.0 116.9 94.3 98 comer, l' below grade Fill 9 200' east, 500' south, area F, norhwest 6" 25.8 116.2 92.4 96 comer, l' below grade Fill 10 300' east, 200' south, area F, norhwest 6" 23.4 117.8 95.5 99 comer, I' below grade Fill 11 300' east, 300' south, area F, norhwest 6" 22.6 117.7 96.0 99 comer, l' below grade Fill 12 300' east, 400' south, area F, norhwest 6" 23.0 117.0 95.1 99 comer, I' below grade Fill F 13 300' east, 500' south, area F, norhwest 6" 24.0 116.9 94.3 98 comer, l' below grade Fill 14 400' east, 200' south, area F, norhwest 6" 24.1 117.3 94.5 98 comer, l' below grade Fill 15 400' east, 300' south, area F, norhwest 6" 22.9 117.1 95.3 99 comer, l' below grade Fill 16 400' east, 400' south, area F, norhwest 6" 23.4 119.7 97.0 101 comer, I' below grade Fill 17 400' east, 500' south, area F, norhwest 6" 23.9 117.1 94.5 98 comer, l' below grade Fill 18 500' east, 200' south, area F, norhwest 6" 23.2 116.9 94.9 98 comer, l' below grade Fill 19 500' east, 300' south, area F, norhwest 6" 23.7 117.3 94.8 98 comer, I' below grade Fill 20 500' east, 400' south, area F, norhwest 6" 1 24.9 116.9 93.6 97 comer, l' below grade LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 7 Page 2 of 3 Report No.: 277411 . ....-..- -.-:;1...--..."::;1 ~ Project No.: 0612510 Client: Duke Construction, LP TEST PROBE MID MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. (%) (pef) (pef) (% max) Fill 21 500' east, 500' south, area F, norhwest 6" 26.3 117.7 93.2 97 corner, I' below grade Fill 22 600' east, 200' south, area F, norhwest 6" 25.2 115.9 92.6 96 corner, I' below grade Fill 23 600' east, 300' south, area F, norhwest 6" 1 23.2 115.6 93.8 97 comer, I' below grade Fill 24 600' east, 400' south, area F, norhwest 6" 25.7 120.3 95.7 99 corner, I' below grade Fill 25 700' east, 200' south, area F, norhwest 6" 1 24.0 116.3 93.8 97 comer, l' below grade Fill 26 700' east, 300' south, area F, norhwest 6" 1 24.1 116.5 93.9 97 corner, I' below grade Fill 27 700' east, 400' south, area F, norhwest 6" 1 23.6 116.9 94.6 98 corner, I' below grade Test results on this report meet project specification. Technician: Joe Jernigan Report Distribution: (I) Duke Construction, LP (I) EXTRANET Started: 8:30am Finished: 4: 15pm K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. J7 Page 3 of 3