Loading...
Gateway BP(3.1)-LR070803 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of In-Place Density Testing Report No.: 292874 Project No.: 0712786 Date of Service: 07/20/2007 Report Date: 08/03/2007 Project: Gateway Business Center Coppell , Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Constructors & Associates Test Method: ASTM 0-2922 ASTM 0-3017 Gauge: Troxler 3430 Gauge Serial No: 35558 Test Mode: DT Standard Counts Moisture Density Current: 604 Current: 2340 Previous: 609 Previous: 2375 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements MID No. Description % (pet) Moisture Density 277809 Dark Brown I Clay 27.0 89.0 Optimum +4 95 min 277810 Tannish Brown I Silty Clay 24.5 93.5 Optimum +4 95min FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (% max) Paving, subgrade 50' south of southwest corner building, 6" 277809 28.1 110.3 86.1 97 southwest packing, building 1 Paving, subgrade 2 200' south of southwest corner building, 6" 277810 24.8 110.7 88.7 95 southwest packing, building 1 Paving, subgrade 3 150' south, 150' east from southwest corner 6" 277809 27.4 108.8 85.4 96 . building Paving, subgrade 4 40' south, 150' east from southwest building 6" 277810 27.1 115.4 90.8 97 comer Paving, subgrade 5 40' south, 300' east from southwest corner 6" 277809 27.7 110.5 86.5 97 building LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB/LB) Page 1 of 3 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of In-Place Density Testing Report No.: 293233 Project No.: 0712786 Date of Service: 07/24/2007 Report Date: 08/03/2007 Project: Gateway Business Center Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Constructors & Associates Test Method: ASTM 0-2922 ASTM D-3017 Gauge: Troxler 3430 Gauge Serial No: 35558 Test Mode: DT Standard Counts Moisture Density Current: 604 Current: 2340 Previous: 609 Previous: 2375 MOISTURE DENSITY RELATIONS Description Moisture % Maximum Density (pet) 89.0 Project Requirements Moisture Density Optimum +4 95 min MID No. 277809 Dark Brown / Clay 27.0 FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (%max) Paving, subgrade 100' south, 300' east from southwest building 6" 277809 29.9 112.2 86.4 97 comer Paving, subgrade 2 200' south, 300' east from southwest building 6" 277809 30.8 113.0 86.4 97 corner Paving, subgrade 3 50' north, 80' east from southeast building 6" 277809 30.3 113.5 87.1 98 corner LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB/LB) Page 1 of 2