Loading...
Gateway BP(3.1)-LR070801 Rone Engineering . Client: Transwestem Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Tes1 Report No.: 292764 Project No.: 0712786 Date of Service: 07/19/2007 Report Date: 08/01/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: LMC Plant: 6 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 3.0" - 5.0" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 1551 Placement Date: 07/19/2007 Weather Conditions: Cloudy Time Sampled: 04:05pm Temperature - Air: 840F Truck No: 7057 Air Content: NA Overall Placement Location: Inlet Sample Location: Inlet at Station 0+48.7, lateral B-2 REPORT OF TESTS Batch time: 03:10pm Concrete: 940F Ticket No: 6308180 Unit Weight (pet): NA Measured Slump (inches) 3.75 Cylinder Marked Date Set No. Tested - 1 1 07/26/2007 1 2 08/16/2007 1 3 08/16/2007 1 4 09/13/2007 Age (days) 7 Diameter (in) 6.00 28 28 56 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 88,910 Area (in') 28.27 Compressive Strength (psi) 3,140 Fracture Type Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB/LB) Page 1 of 2 - - Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestem Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of In-Place Density Testing Report No.: 293702 Project No.: 0712786 Date of Service: 07/27/2007 Report Date: 08/01/2007 Project: Gateway Business Center Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Constructors & Associates Test Method: ASTM D-2922 ASTM D-3017 Gauge: Troxler 3430 Gauge Serial No: 35557 Test Mode: DT Standard Counts Moisture Density Current: 660 Current: 2660 Previous: 592 Previous: 2747 MOISTURE DENSITY RELATIONS MID No. 277809 Description Moisture % Maximum Density (pet) 89.0 Project Requirements Moisture Density Optimum +4 95 min Dark Brown I Clay 27.0 FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (%max) Paving, subgrade 40' north, 250' east from the southwest corner 6" 277809 30.2 111.8 85.9 97 of southwest parking area, final Paving, subgrade 2 175' north, 30' east from the southwest corner 6" 277809 28.8 111.8 86.8 98 of southwest parking area, final Paving, subgrade 3 30' north, 75' east from the southwest corner of 6" 277809 29.3 110.9 85.8 96 southwest parking area, final Paving, subgrade 4 75' north, 20' east from the southwest corner of 6" 277809 27.7 110.6 86.6 97 southwest parking area, final LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB/LB) Page 1 of 2