Loading...
Gateway BP(3.1)-LR070815 Rone Engineering . Client: T ranswestern 5001 Spring Dallas, JC 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Tes1 Report No.: 292003 Project No.: 0712786 Date of Service: 07/12/2007 Report Date: 08/15/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring sample~ back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi Mix Plant: 136 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 830J1521 Placement Date: 07/12/2007 Weather Conditions: Clear Time Sampled: 10: 15am Temperature - Air: 890F Truck No: 1188 Air Content: NA Overall Placement Location: Pier cap on grids D.9/12.6 Sample Location: Grid location D.9/12.6 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Marked Date (7- Diameter Area Load Set No. Tested (in) (in') (Ibs) 1 1 07/19/2007 6.00 28.27 89,060 1 2 08/09/2007 28 6.00 28.27 121,590 1 3 08/09/2007 28 6.00 28.27 116,580 Average 1 4 09/06/2007 56 Batch time: Concrete: 940F Ticket No: 13690976 Unit Weight (pet): NA Measured Slump (inches) 5.25 fi/~ Fracture Type Unbonded Cap Unbonded Cap Unbonded Cap 9 \d'~J1 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reprodUCed except in full without the written approval of Rone Engineering Services, Ltd. (LB/KW) Page 1 of 2