Duke Lesley 2A-LR070827 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 295604 Project No.: 0712932 Date of Service: 08/14/2007 Report Date: 08/27/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Duke Construction, LP Test Method: ASTM D-6938 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 738 Current: 2554 Previous: 730 Previous: 2507 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements MID No. Description % (pet) Moisture Density 294619 Lime Treated Brown I Silty Sandy Clay 32.7 87.0 Optimum +4 95 min 272998 Brown I Silty Clay wi Organics 22.5 96.5 Optimum +4 95min FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (%max) Lime Treated Building Cap Gridline N5/9 6" 294619 33.5 112.7 84.4 97 Lime Treated Building Cap 2 Gridline 8.5/9 6" 294619 36.2 112.8 82.8 95 Lime Treated Building Cap 3 Gridline C.5/9 6" 294619 35.2 113.3 83.8 96 Lime Treated Building Cap 4 Gridline 0.5/9 6" 294619 34.7 113.4 84.2 97 Lime Treated Building Cap 5 Gridline E.5/9 6" 294619 33.5 113.5 85.0 98 Lime Treated Building Cap 6 Gridline F.5/9 6" 294619 35.6 114.0 84.1 97 Lime Treated Building Cap 7 Gridline G.5/9 6" 294619 35.0 113.1 83.8 96 Lime Treated Building Cap 8 Gridline H.5/9 6" 294619 33.2 114.4 85.9 99 Lime Treated Building Cap 9 Gridline 1.5/9 6" 294619 35.5 113.8 84.0 97 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KWIKW) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 295604 Project No.: 0712932 Date of Service: 08/14/2007 Report Date: 08/27/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (% max) - Lime Treated Building Cap 10 Gridline J.5/9 6" 294619 32.9 114.8 86.4 99 Utility Backfill 11 12" waterline W-1, station 13+00, 2' below 6" 272998 24.2 117.1 94.3 98 grade Utility Backfill 12 12" waterline W-1, station 13+00, final 6" 272998 24.1 117.0 94.3 98 Utility Backfill 13 12" waterline W-1, station 10+00, 2' below 6" 272998 23.9 117.0 94.4 98 grade Utility Backfill 14 12" waterline W-1, station 10+00, final 6" 272998 23.3 117.3 95.1 99 Utility Backfill 15 12" waterline W-1, station 7+00, 2' below grade 6" 272998 24.9 116.8 93.5 97 Utility Backfill 16 12" waterline W-1, station 7+00, final 6" 272998 23.0 116.5 94.7 98 Technician: Joe Jernigan Rone Engineering See Report 295603 for technician time~~ Report Distribution: '. . Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne .' . . .. . . . (1-ec copy) .' . . 1-cc City of Coppell Attn: Mr. Lee Stone K. Scott Watson, AET 1-cc City of Coppell Attn: Mr. Larry Davis Project Manager ~ LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 2 of 2