Gateway BP(3.1)-LR070831 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 296613 Project No.: 0712786 Date of Service: 08/23/2007 Report Date: 08/31/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 136 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 3" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM '::-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 1501 Placement Date: 08/23/2007 Weather Conditions: Clear, warm Time Sampled: 10:03am Batch time: 09:34am Temperature - Air: 830F Concrete: 890F Truck No: 1350 Ticket No: 13695089 Air Content: 1.6% Unit Weight (pcf): NA Overall Placement Location: Paving, building 1, slab, level 1, grid lines 15.5-A/12-9.0 Measured Slump (inches) 5.5 Sample Location: Same as above REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 1 1 08/30/2007 7 6.00 28.27 81,960 2,900 Unbonded Cap 1 2 09/20/2007 28 1 3 09/20/2007 28 4 10/18/2007 56 Remarks: Water added at site: 5 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMlLB) Page 1 of 2 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 296560 Project No.: 0712786 Date of Service: 08/23/2007 Report Date: 08/31/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 88 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 i\STi\r1 '..:: 31 texcept 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 1524 Placement Date: 08/23/2007 Weather Conditions: Clear, warm Time Sampled: 03:50pm Batch time: 03:03pm Temperature - Air: 760F Concrete: 860F Truck No: 1219 Ticket No: 88053502 Air Content: 4.6% Unit Weight (pcf): NA Overall Placement Location: Paving, parking lot, elevation 525./0, :;2b.50, tl2/.JO, 02/.70 -. Measured Slump (inches) 5.5 Sample Location: Same as above REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 1 1 08/30/2007 7 6.00 28.27 83,230 2,940 Unbonded Cap 1 2 09/20/2007 28 1 3 09/20/2007 28 1 4 10/18/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMlLB) Page 1 of 5 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 296560 Project No.: 0712786 Date of Service: 08/23/2007 Report Date: 08/31/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 88 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 f\S eM C-31 (exC8fJt ! 0.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 5.0 Mix Design 1.0.: 1524 Placement Date: 08/23/2007 Weather Conditions: Clear, warm Time Sampled: 05:11am Batch time: 04:29am Temperature - Air: 740F Concrete: 810F Truck No: 1219 Ticket No: 88053515 Air Content: 4.7% Unit Weight (pcf): NA Overall Placement Location: Paving, parking jot, eievatron~25.70, 526.50, 527 \,\ 5?7.70 ~ ~-- - ~ Sample Location: Same as above REPORT OF TESTS Cylinder Marked Date Set No. Tested 2 1 08/30/2007 2 2 09/20/2007 2 3 09/20/2007 2 4 10/18/2007 Age (days) 7 Diameter (in) 6.00 28 28 56 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 79,400 Compressive Strength pSI) 2,810 Fracture Type Unbonded Cap Area (in2) 28.27 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMfLB) Page 2 of 5 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 296560 Project No.: 0712786 Date of Service: 08/23/2007 Report Date: 08/31/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 88 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 AS 1M (-3 i (ext.:epl 10. i .2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 Measured Slump (inches) 5.0 Mix Design I.D.: 1524 Placement Date: 08/23/2007 Weather Conditions: Clear, warm Time Sampled: 06:30am Batch time: 05:40am Temperature - Air: 750F Concrete: 880F Truck No: 1198 Ticket No: 88053523 Air Content: 5.3% Unit Weight (pct): NA Overall Placement Location: paving, pai:(:ng-Jot,c:c\iatiO?1-5[5-';~, )Lb.tJO, b2!.Ju, 52/.flJ -- -- - Sample Location: Same as above REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 90,320 Cylinder Marked Date Set No. Tested 3 1 08/30/2007 3 2 09/20/2007 3 3 09/20/2007 3 4 10/18/2007 Age (days) 7 Diameter (in) 6.00 28 28 56 Compressive Strength (psi) 3,190 Fracture Type Unbonded Cap Area (in2) 28.27 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. OUf letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/LB) Page 3 of 5 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 296560 Project No.: 0712786 Date of Service: 08/23/2007 Report Date: 08/31/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 88 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 - ..- -ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 1524 Placement Date: 08/23/2007 Weather Conditions: Clear, warm Time Sampled: 08:10am Batch time: 07:07am Temperature - Air: 760F Concrete: 840F Truck No: 1046 Ticket No: 88053533 Air Content: 5.7% Unit Weight (pcf): NA Overall Placement Location: Paving. pa!klng iontEwcftimr'3L5.70. 326.50, 527-;'C" 52"/.70 - ----- Measured Slump (inches) 5.5 Sample Location: Same as above REPORT OF TESTS Cylinder Marked Date Set No. Tested 4 1 08/30/2007 4 2 09/20/2007 4 3 09/20/2007 4 4 10/18/2007 Age (days) 7 Diameter (in) 6.00 28 28 56 Remarks: Water added at site: 10 gallons Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 96,910 Compressive Strength (psi) 3,430 Fracture Type Unbonded Cap Area (in') 28.27 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services. LId. (TMlLB) Page 4 of 5 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 296179 Project No.: 0712786 Date of Service: 08/20/2007 Report Date: 08/31/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Constructors & Associates Concrete Supplier: Redi Mix Plant: 136 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 P"STM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 Mix Design I.D.: 830J1521 Placement Date: 08/20/2007 Weather Conditions: Clear Time Sampled: 01 :30pm Temperature - Air: 920F Truck No: 1186 Air Content: 4.2% Overall Placement Location: Grade beam on south side of buildings 1 and 2, Measured Slump (inches) 4.0 Batch time: 12:52pm Concrete: 970F Ticket No: 13694648 Unit Weight (pet): NA grids on building 1 - 7.5 to 10.0, line F Sample Location: Grid line F.0/6.5 REPORT OF TESTS Cylinder Marked Date Age Set No. Tested (days) 1 1 08/27/2007 7 2 09/17/2007 28 3 09/17/2007 28 4 1011512007 56 Diameter (in) 6.00 Remarks: Water added at site: 10 gallons Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 98,300 Compressive Strength (psi) 3,480 Fracture Type Unbonded Cap Area (in2) 28.27 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/LB) Page 1 of 2 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 294357 Project No.: 0712786 Date of Service: 08/02/2007 Report Date: 08/31/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 136 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ;STlIJ: C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 830J1521 Placement Date: 08/02/2007 Weather Conditions: Clear Time Sampled: 03:00pm Temperature - Air: 940F Truck No: 1216 Air Content: 3.7% Overall Placement Location: Grade beam, grid lines FI7.5-10, south side of building 1 Measured Slump (inches) 5.5 Batch time: 02:51pm Concrete: 950F Ticket No: 13693049 Unit Weight (pcf): NA Sample Location: Grid lines F/9.5, south side of building 1 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 08/09/2007 7 6.00 28.27 86,460 3,060 Unbonded Cap 2 08/30/2007 28 6.00 28.27 113,980 4,030 Unbonded Cap 3 08/30/2007 28 6.00 28.27 113,940 4,030 Unbonded Cap Average 4,030 4 09/27/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KWILB) Page 1 of 2