Northlake College-LR070920
K L E I N F E L D E R
2211 Century Center Blvd., Suite 101, Irving, TX 75062
972-870-0808 Metro 972-953-0398 Fax 972-870-0802
IN-PLACE MOISTURE DENSITY TEST RESULTS
To: Dallas County Community College Dist. Test Date: 9/18/2007
1505 South Lamar, Suite 1015 Project No: 87015
Dallas, Texas 75215 Report Date: 9/20/2007
Report No: 097387
Project: North Lake College, N Campus Definitions of Terms
Location: W Sandy Lake Road @ SH 121 ROP- Rt Otr Point CL - Centerline
Field Rep: J. Schuler LQP - Lt Qtr Point Sta - Station
Test Test Location Depth D Wet Field Dry Proctor Percent
No. Lift 0 Density Moisture Density No. Proctor
(%) (pet) Density
Blda Pad Subgrade /
1 15' E and 120' N of SW corner 1 st 126.4 21.2* 104.3 001354 107.4
2 75' E and 80' N of SW corner 1 st 125.6 21.2* 103.6 001354 I 106.7
3 100' Wand 110' N of SE corner 1 st 122.5 22.3* 100.2 001354 , 103.2
4 20' Wand 30' N of SE corner 1 st 126.0 21.2* 104.0 001354 107.1
"---
Proctor No: Description Opt. Moisture Max. Density
001354 Gray fat clay 22.6 97.1
Specs. Gauge No: 28714 Test Methods: ASTM D 2922
Dens. (%) Min 95 Std. Density Count: 2297 ASTM D 3017
Moist. (%) +1 to +5 Std. Moist Count: 658 ASTM D 698
Trans. Depth (in.): 6 ~
Remarks: d I J ,
(j) 1~
. I
Reports to: i
Starling Richardson Const.; Attn: Eric Stanaland (eps@starlingrichardson.com) ,/.. ~
Starling Richardson Const.; Attn: Andy Munoz (amunoz@starlingrichardson.com) ( ( KLEI FEL'~. A / ~Jil fIJ
DCCCD Bond Office; Attn: Brenda Spinelli (brenda.spinelli@dcccd.edu) ,
DCCCD Bond Office; Attn: James Williams Uames.williams@dcccdedu) 1M~ '7YDlj r
DCCCD Bond Office; Attn: Mike Daniels (mike.daniels@dcccd.edu)
Jacobs; Attn: Andrea Stogner (Andrea.stogner@jacobs.com) I Joel Peters, PEl I I ~
Jacobs: Attn: Jennifer Blount (Jennifer.blount@jacobs.com)
1- City of Coppell; Attn: Larry Davis
1- City of Coppell; Attn: Lee Stone The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested andlor inspected. They are not intended to be
Indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety.
K L E I N F E L D E R
2211 Century Center Blvd., Suite 101, Irving, TX 75062
972-870-0808 Metro 972-953-0398 Fax 972-870-0802
IN-PLACE MOISTURE DENSITY TEST RESUL TS
To: Dallas County Community College Dist. Test Date: 9/18/2007
1505 South Lamar, Suite 1015 Project No: 87015
Dallas, Texas 75215 Report Date: 9/20/2007
Report No: 097391
Project: North Lake College, N Campus Definitions of Terms
Location: W Sandy Lake Road @ SH 121 RQP- Rt Qtr Point CL - Centerline
Field Reo: J. Schuler LOP - Lt Otr Point Sta - Station
Test Test Location Depth D Wet Field Dry Proctor Percent
No. Lift 0 Density Moisture Density No. Proctor
(%) (pet) Density
Retests
1 # 1 from 9/18 1 st 120.5 23.8 97.3 001354 100.2
2 # 2 from 9/18 1st 120.2 24.2 96.8 001354 99.7
3 # 3 from 9/18 1 st 119.2 24.0 96.1 001354 99.0
4 # 4 from 9/18 1 st 120.2 23.9 97.0 001354 99.9
Proctor No: Description Opt. Moisture Max. Density
001354 Gray fat clay 22.6 97.1
Specs. Gauge No: 28714 Test Methods: ASTM D 2922
Dens. (%) Min 95 Std. Density Count: ASTM D 3017
Moist. (%) +1 to +5 Std. Moist Count: ASTM D 698
Trans. Depth (in.): 6
Remarks:
Reports to:
Starling Richardson Const.; Atln: Eric Stanaland (eps@starlingrichardson.com)
Starling Richardson Const.; Atln: Andy Munoz (amunoz@starlingrichardson.com)
DCCCD Bond Office; Atln: Brenda Spinelli (brenda.spinelli@dcccd.edu) (yjZ
DCCCD Bond Office; Attn: James Williams (james.williams@dcccd.edu)
DCCCD Bond Office; Attn: Mike Daniels (mike.daniels@dcccd.edu) '//~
Jacobs; Attn: Andrea Stogner (Andrea.stogner@jacobs.com) /Joel Peters, P.E.
Jacobs; Attn: Jennifer Blount (Jennifer.blount@jacobs.com)
1- City of Coppell; Attn: Larry Davis
1- City of Coppell; Atln: Lee Stone
The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected. They are not intended to be
indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety.