Northlake College-LR070918
K l E I N F E L D E R
2211 Century Center Blvd., Suite 101, Irving, TX 75062
972-870-0808 Metro 972-953-0398 Fax 972-870-0802
IN-PLACE MOISTURE DENSITY TEST RESUL TS
To: Dallas County Community College Dist. Test Date: 9/17/2007
1505 South Lamar, Suite 1015 Project No: 87015
Dallas, Texas 75215 Report Date: 9/18/2007
Report No: 097361
Project: North Lake College, N Campus Definitions of Terms
Location: W Sandy Lake Road @ SH 121 RQP- Rt Qtr Point CL - Centerline
Field Rep: M. Humphrey LQP - Lt Qtr Point Sta - Station
Test Test Location Depth 0 Wet Field Dry Proctor Percent
No. Lift 0 Density Moisture Density No. Proctor
(%) (oct) Density
Blda Pad f\.
1 CL 4-C - Retest of test # 1 from 9/14 Subgrade 120.9 22.5 98.7 001358 98.8
2 CL 7 -C - Retest of test # 2 from 9/14 Subgrade 122.7 22.9 99.8 001358 99.9
3 CL J-3.5 Subgrade 120.6 22.4 98.5 001358 98.6
4 CL F-17 Subgrade 120.2 23.0 97.7 001358 97.8
5 CL F-3 Subgrade 122.2 23.3 99.1 001358 99.2
Firelane
6 120' 1 st 122.6 24.8 98.2 001358 98.3
7 230' 1 st 118.6 24.1 95.6 001358 95.7
8 330' 1 st 120.6 25.0 96.5 001358 96.6
9 400' 1 st 120.8 24.4 97.1 001358 97.2
-
, .::......
Proctor No: / / \ Description Oot. Moisture Max. Density
001358 , Gray'at clay} 21.1 99.9
, I
/
'- ../
Specs. Gauge No: 29979 Test Methods: ASTM D 2922
Dens. (%) Min 95 Std. Density Count: 656 ASTM D 3017
Moist. (%) +1 - +5 Std. Moist Count: 2490 ASTM D 698
Trans. Deoth (in.): 6
Remarks
Reports to:
Starling Richardson Const.; Alln: Eric Stanaland (eps@starlingrichardson.com)
Starling Richardson Const.; Alln: Andy Munoz (amunoz@starlingrichardson.com)
DCCCD Bond Office; Alln: Brenda Spinelli (brenda.spinelli@dcccd.edu) adF~
DCCCD Bond Office; Alln: James Williams Oames.williams@dcccd.edu)
DCCCD Bond Office; Alln: Mike Daniels (mike.daniels@dcccd.edu)
Jacobs; Alln: Andrea Stogner (Andrea.stogner@jacobs.com) f/ Joel Peters, P.E~
Jacobs; Alln: Jennifer Blount (Jennifer.blount@jacobs.com)
1- City of Coppell; Alln: Larry Davis
1- City of Coppell; Alln: Lee Stone
The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected. They are not intended to be
indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety.