Loading...
Duke Lesley 1A-LR070908 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Project: Point West VI / - 6ul-'pell, I c^<= .- Services: Perform In-Place Density Testing Contractor: Duke Construction, LP Test Method: ASTM D-6938 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In-Place Density Testing Report No.: Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 735 Current: 2500 Previous: 729 Previous: 2514 MOISTURE DENSITY RELATIONS MID No. 272998 Description Brown I Silty Clay wI Organics Test No Test Location Maximum Moisture Density Project Requirements % (pet) Moisture Density 22.5 96.5 Minimum +4 92-96 FIELD DENSITY TESTS Probe MID Moisture Wet Density Dry Density Density Depth No. % (pet) (pet) (%max) 6" 272998 19.7* 126.8 105.9 110* 6" 272998 31.8 118.5 89.9 93 6" 272998 30.7 118.7 90.8 94 6" 272998 31.1 118.4 90.3 94 Fill 8' south, 100' east from southwest corner of building pad, final Fill 2 Retest of test 1 Fill 3 8' south, 300' east from southwest corner of building pad, 1 st lift Fill 4 8' south, 600' east from southwest corner of building pad, 1 st lift An asterisk (*) appears next to results which do NOT meet the project specifications. Remarks: High compaction due to low moisture. "-. Technician: Joe Jernigan Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Emmit Coots (1-ec copy) 1-cc City of Coppell Attn: Mr. Larry Davis 1-cc City of Coppell Attn: Mr. Lee Stone Started: 09:30am Finished: 11 :OOam Rone Engineering p~.~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/LB) Page 1 of 1 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 297663 Project No.: 0713408 Date of Service: 08/31/2007 Report Date: 09/08/2007 Project: Point West VI Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Duke Construction, LP Test Method: ASTM D-6938 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 734 Current: 2501 Previous: 731 Previous: 2484 MOISTURE DENSITY RELATIONS MID No. 272998 Description Brown I Silty Clay wi Organics Moisture % Maximum Density (pet) 96.5 Project Requirements Moisture Density Minimum +4 92-96 22.5 ------- ._--_._-~-_.- Test No Test Location FIELD DENSITY TESTS Probe MID Depth No. Moisture Wet Density Dry Density Density % (pet) (pet) (% maxI Fill 5' south, 300' from northwest corner of building 6" 272998 31.5 118.5 90.1 93 pad, l' below grade Fill 2 5' south, 550' from northwest corner of building 6" 272998 30.4 117.5 90.1 93 pad, 2' below grade Fill 3 5' south, 550' from northwest corner of building 6" 272998 31.8 118.4 89.8 93 pad, l' below grade Technician: Joe Jernigan Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Emmit Coots (1-ec copy) 1-cc City of Coppell Attn: Mr. Larry Davis 1-cc City of Coppell Attn: Mr. Lee Stone Started: 12:00pm Finished: 03:00pm Rone Engineering p~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/LB) Page 1 of 1 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Project: Point West VI Coppell, Texas Services: Perform In-Place Density Testing 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214)630-9745 Report of In-Place Density Testing Report No.: 297436 Project No.: 0713408 Date of Service: 08/30/2007 Report Date: 09/08/2007 PROJECT DATA Contractor: Duke Construction, LP Test Method: ASTM 0-6938 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 731 Current: 2484 Previous: 735 Previous: 2500 MOISTURE DENSITY RELATIONS MID No. 272998 Description Brown I Silty Clay wi Organics Test No Test Location Fill 8' south, 350' east from southwest corner of building pad, l' below grade Fill 2 8' south, 550' east from southwest corner of building pad, 2' below grade Fill 3 5' north, 50' east from northwest corner of building pad, final Fill 4 5' north, 150' east from northwest corner of building pad, l' below grade Maximum Moisture Density Project Requirements % (pet) Moisture Density 22.5 96.5 Minimum +4 92-96 . -- -- -- -- ~ FIELD DENSITY TESTS Probe MID Moisture Wet Density Dry Density Density Depth No. % (pet) (pet) (%max) 6" 272998 30.4 118.5 90.9 94 6" 272998 28.3 118.3 92.2 96 6" 272998 29.2 115.0 89.0 92 6" 272998 30.4 115.7 88.7 92 Technician: Joe Jernigan Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Emmit Coots (1-ec copy) 1-cc City of Coppell Attn: Mr. Larry Davis 1-cc City of Coppell Attn: Mr. Lee Stone Started: 01 :OOpm Finished: 05:15pm Rone Engineering p~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other teature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB/LB) Page 1 of 1