Duke Lesley 2A-LR070907 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 297437 Project No.: 0712932 Date of Service: 08/30/2007 Report Date: 09/07/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Duke Construction, LP Test Method: ASTM 0-6938 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 731 Current: 2484 Previous: 735 Previous: 2500 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements MID No. Description % (pet) Moisture Density 272998 Brown I Silty Clay wI Organics 22.5 96.5 Minimum +4 92-96 27:;>9% 8.,)\""11 ! Silt" Clay wI Organic...<>- 22.5 96.f.. - Opti~.)..4 ..9amin - FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (%max) - Fill Detention pond, east bank, final 6" 272998 24.1 117.5 94.7 98 Fill 2 Detention pond, north bank, final 6" 272998 22.7 117.4 95.7 99 Fill 3 Detention pond, west bank, final 6" 272998 24.2 117.1 94.3 98 Fill 4 Detention pond, south bank, final 6" 272998 24.8 116.9 93.7 97 Fill 5 Detention pond, bottom, final 6" 272998 24.2 116.9 94.1 98 Fill 6 6" Sanitary sewer center line, 250' from north 6" 272998 30.3 119.2 91.5 95 end, 3' below grade Fill 7 6" Sanitary sewer center line, 250' from north 6" 272998 31.2 118.7 90.5 94 end, 2' below grade Fill 8 6" Sanitary sewer center line, 250' from north 6" 272998 30.9 118.7 90.7 94 end, l' below grade LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/LB) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 297437 Project No.: 0712932 Date of Service: 08/30/2007 Report Date: 09/07/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (%max) Fill 9 6" Sanitary sewer center line, 250' from north 6" 272998 30.7 119.3 91.3 95 end, final Fill 10 6" Sanitary sewer center line, 450' from north 6" 272998 32.0 118.7 89.9 93 end, 3' below grade Fill 11 6" Sanitary sewer center line, 450' from north 6" 272998 30.2 118.6 91.1 94 end, 2' below grade "_~ k --'-.- ~i!L 12 6" Sanitary sewer center line, 450' from noith 6" 272998 31.1 118.4 90.3 94 end, l' below grade Fill 13 6" Sanitary sewer center line, 450' from north 6" 272998 31.8 118.5 89.9 93 end, final Technician: Joe Jernigan Started: 10:30am Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne (1-ec copy) 1-cc City of Coppell Attn: Mr. Lee Stone 1-cc City of Coppell Attn: Mr. Larry Davis Finished: 01 :OOpm Rone Engineering p~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services. Ltd. (CH/LB) Page 2 of 2