Loading...
Gateway BP(3.1)-LR070908 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 297387 Project No.: 0712786 Date of Service: 08/30/2007 Report Date: 09/08/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 88 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 5" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 1524 Placement Date: 08/30/2007 Weather Conditions: Cloudy, calm Time Sampled: 04:03am Batch time: 03:29am Temperature - Air: 780F Concrete: 840F Truck No: 1303 Ticket No: 88053750 Air Content: 4.3% Unit Weight (pcf): NA Overall Placement Location: Station 525.70-527.10 ridge, Station 525.20-527.40 ridge, page C2.01 Measured Slump (inches) 5.0 Sample Location: Same as above REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 1 1 09/06/2007 7 6.00 28.27 100,820 3,570 Cone/Split 2 09/27/2007 28 3 09/27/2007 28 4 10/25/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LBILB) Page 1 of 5 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 297387 Project No.: 0712786 Date of Service: 08/30/2007 Report Date: 09/08/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 88 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 5" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 1524 Placement Date: 08/30/2007 Weather Conditions: Cloudy, calm Time Sampled: 04:45am Batch time: 04:03am Temperature - Air: 760F Concrete: 880F Truck No: 1046 Ticket No: 88053753 Air Content: 4_7% Unit Weight (pcf): NA Overall Placement Location: Station 525.70-527.10 ridge, Station 525.20-527.40 ridge, page C2.01 Measured Slump (inches) 5.0 Sample Location: Same as above REPORT OF TESTS Cylinder Marked Date Set No. Tested 2 1 09/06/2007 2 2 09/27/2007 2 3 09/27/2007 2 4 10/25/2007 Age (days) 7 Diameter (in) 6.00 28 28 56 Remarks: Water added at site: 10 gallons Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 95,080 Compressive Strength (psi) 3,360 Fracture Type Shear Area (in') 28.27 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB/LB) Page 2 of 5 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 297387 Project No.: 0712786 Date of Service: 08/30/2007 Report Date: 09/08/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 88 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 5" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 1524 Placement Date: 08/30/2007 Weather Conditions: Cloudy, calm Time Sampled: 05:30am Batch time: 05:08am Temperature - Air: 710F Concrete: 830F Truck No: 1303 Ticket No: 88053759 Air Content: 4.2% Unit Weight (pet): NA Overall Placement Location: Station 525.70-527.10 ridge, Station 525.20-527.40 ridge, page C2.01 Measured Slump (inches) 5.5 Sample Location: Same as above REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 3 1 09/06/2007 7 6.00 28.27 102,240 3,620 Cone/Split 3 2 09/27/2007 28 3 3 09/27/2007 28 3 4 10/25/2007 56 Remarks: Water added at site: 15 gallons LIMITATIONS The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB/LB) Page 3 of 5 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 297387 Project No.: 0712786 Date of Service: 08/30/2007 Report Date: 09/08/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 88 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 5" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 1524 Placement Date: 08/30/2007 Weather Conditions: Cloudy, calm Time Sampled: 06:35am Batch time: 06:00am Temperature - Air: 720F Concrete: 900F Truck No: 1348 Ticket No: 13695739 Air Content: 3.7% Unit Weight (pcf): NA Overall Placement Location: Station 525.70-527.10 ridge, Station 525.20-527.40 ridge, page C2.01 Measured Slump (inches) 5.0 Sample Location: Same as above REPORT OF TESTS Cylinder Marked Date Set No. Tested 4 1 09/06/2007 4 2 09/27/2007 4 3 09/27/2007 4 4 10/25/2007 Age (days) 7 Diameter (in) 6.00 28 28 56 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 85,190 Compressive Strength (psi) 3,010 Fracture Type Cone/Split Area (in2) 28.27 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LBfLB) Page 4 of 5 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of In-Place Density Testing Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report No.: 297294 Project No.: 0712786 Date of Service: 08/29/2007 Report Date: 09/08/2007 Project: Gateway Business Center Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Constructors & Associates Test Method: ASTM 0-6938 Gauge: Troxler 3430 Gauge Serial No: 33305 Test Mode: DT Standard Counts Moisture Density Current: 549 Current: 2549 Previous: 552 Previous: 2570 MOISTURE DENSITY RELATIONS MID No. 278271 Description Moisture % Maximum Density (pet) 118.0 Project Requirements Moisture Density -2/+2 95 min Brown / Clayey Sand 11.0 FIELD DENSITY TESTS 2 Probe MID Moisture Wet Density Dry Density Density Test Location Depth No. % (pet) (pet) (%max) Leave-outs l' west, 35' north from southeast corner of 6" 278271 12.0 127.5 113.8 96 building 2, final Leave-outs l' west, 150' north from southeast corner of 6" 278271 10.3 125.8 114.1 97 building 2, final Leave-outs l' north, 55' west from southeast corner of 6" 278271 9.8 124.0 112.9 96 building 2, final Leave-outs 75' north, l' west from southeast corner of 6" 278271 10.3 123.4 111.9 95 building 1, final Leave-outs 200' north, l' west from southeast corner of 6" 278271 9.6 123.4 112.6 95 building 1, final Test No 3 4 5 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CHfLB) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of In-Place Density Testing Report No.: 297294 Project No.: 0712786 Date of Service: 08/29/2007 Report Date: 09/08/2007 Project: Gateway Business Center Coppell, Texas Services: Perform In-Place Density Testing Report Distribution: Orig: Transwestern Commercial Services (Dallas, TX) Attn: Mr. Ric Nelson (1-cc copy) 1-ec Constructors & Associates Attn: Mr. Frank Castro 1-cc City of Coppell Attn: Mr. Larry Davis 1-ec Mike Delvin Attn: Mr. Mike Delvin 1-cc Murray Construction Co., Inc. Attn: Mr. Terence Babler 1-cc City of Coppell Attn: Mr. Lee Stone 1-ec AECC, Inc. Attn: Mr. Brant Ince 1-ec Delaware Investment Advisers Attn: Mr. Keith Schinnerer PE 1-cc Aztec Environmental Attn: Mr. Mike Sexton Technician: Scott Fagan Started: 02:15pm Finished: 03:15pm Rone Engineering ~~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CHfLB) Page 2 of 2