Loading...
Gateway BP(3.1)-LR070907 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of In-Place Density Testing Report No.: 297317 Project No.: 0712786 Date of Service: 08/29/2007 Report Date: 09/07/2007 Project: Gateway Business Center Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Constructors & Associates Test Method: ASTM 0-6938 Gauge: Troxler 3430 Gauge Serial No: 33305 Test Mode: DT Standard Counts Moisture Density Current: 549 Current: 2549 Previous: 552 Previous: 2570 MOISTURE DENSITY RELATIONS MID No. 277811 Description Tannish Brown & Dark Brown / Silty Clay Moisture % Maximum Density (pet) 94.0 Project Requirements Moisture Density Optimum +4 95 min 24.0 FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (%max) Exterior grade beam backfill l' south, 40' west from southeast corner of 6" 277811 24.6 112.3 90.1 96 building 2, final LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB/LB) Page 1 of 2