Loading...
Gateway BP(3.1)-LR070830 (2) Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of Cylinder Collection Report No.: 296379 Project No.: 0712786 Date of Service: 08/22/2007 Report Date: 08/30/2007 Project: Gateway Business Center Coppell, Texas Services: Pick Up Compressive Strength Test Specimens Cast Prior To This Date Report of Collection On this date, a Rone Engineering Services, Ltd. representative arrived on site as scheduled to pick up compressive strength test specimens cast prior to this date. LIMITATIONS The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ud (TM/LB) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 proje : Gate ppell, Texas Services: Structural Steel Re-Inspection Report of Structural Steel Inspection Report No.: 606749 Project No.: 0712786 Date of Service: 08/23/2007 Report Date: 08/30/2007 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of Inspection Drawings Utilized: Structural pi I~ 'Jn/~ Service: Perform Structural Steel Inspection as detailed below: Locations and Items Inspected: Buildings 1 and 2, report dated 08/22/07. blocked out areas from Discrepancies / Comments: Discrepancies for arc spot welds and Tek screws have been corrected a . Note: Block out areas not yet inspected. Deck welds require paint touch-up per job specifications. Perimeter angle top side only, discrepancies corrected and cleared from the noted report. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMfLB) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of Structural Steel Inspection Report No.: 606749 Project No.: 0712786 Date of Service: 08/23/2007 Report Date: 08/30/2007 Project: Gateway Business Center Coppell, Texas Services: Structural Steel Re-Inspection Report Distribution: Orig: Transwestem Commercial Services (Dallas, TX) Attn: Mr. Ric Nelson (1-cc copy) 1-ec Constructors & Associates Attn: Mr. Frank Castro 1-cc City of Coppell Attn: Mr. Larry Davis 1-ec Mike Delvin Attn: Mr. Mike Delvin 1-cc Murray Construction Co., Inc. Attn: Mr. Terence Babler 1-cc City of Coppell Attn: Mr. Lee Stone 1-ec AECC, Inc. Attn: Mr. Brant Ince 1-ec Delaware Investment Advisers Attn: Mr. Keith Schinnerer PE 1-cc Aztec Environmental Attn: Mr. Mike Sexton Technician: Ron Cuba, CWI-97040341 Started: 01 :45pm Finished: 03:45pm Rone Engineering ~~.~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMILB) Page 2 of 2