Loading...
Duke Lesley-LR070926 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 298569 Project No.: 0612510 Date of Service: 09/13/2007 Report Date: 09/26/2007 Project: Lesley Infrastructure Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Concrete Supplier: TXI Plant: 131 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 8274 Placement Date: 09/13/2007 Weather Conditions: Cloudy Time Sampled: 10:30am Temperature - Air: 860F Truck No: 1572 Air Content: 4.5% Overall Placement Location: "Red" stamped concrete median noses Batch time: 09:35am Concrete: 900F Ticket No: 528602 Unit Weight (pet): NA Measured Slump (inches) 5.0 Sample Location: Median nose at Beltline/Dividend intersection and median Stations 43+00 and 44+25 REPORT OF TESTS Cylinder Marked Date Set No. Tested 1 1 09/20/2007 1 2 10/11/2007 1 3 10/11/2007 1 4 11/08/2007 Age (days) 7 Diameter (in) 6.00 28 28 56 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 110,440 Compressive Strength (psi) 3,910 Fracture Type Cone/Split Area (in') 28.27 Started: 09:30am Finished: 11 :30am Technician: Denny Harris Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Alex Bennett PE (1-ec copy) 1-ec Lacy Construction Attn: Mr. Kevin Briles 1-cc City of Coppell Attn: Mr. Lee Stone 1-cc City of Coppell Attn: Mr. Larry Davis Rone Engineering P-~ ~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KWIKW) Page 1 of 1