Gateway BP(3.1)-LR070919 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of Structural Steel Inspection Report No.: 606823 Project No.: 0712786 Date of Service: 09/12/2007 Report Date: 09/19/2007 Project: Gateway Business Center Coppell, Texas Services: Structural Steel Inspection Report of Inspection Column Base Plates L 0 c a tio n: 1. An c h 0 r bolt te n s io n ve rific a tio n , build in 9 1, grid lin e s A -E /1 -1 8. 2. V is u a I grout verification under colum n base plates, building 1, grid lines A-E/1-18. 3. Bolt tension verification of expansion anchors at stairs, tube steel co lu m n san d s ta ir s trin 9 e rs to con c re te s la b, build in 9 1, grid lin e s A -E /1 -1 8. Non Cod e Com pliant Compliant AWS D 1 .1 A IS C Job Specs Job Specs Anchor Bolt Tension Verification ( 1 ) x x I R F I Grouted Bas e P la te s (2) x Job Specs Bolt Ten s io n Verification of Expansion Anchor(3) x x Job Specs Com men ts LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMlJB) Page 1 of 5 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of Structural Steel Inspection Report No.: 606823 Project No.: 0712786 Date of Service: 09/12/2007 Report Date: 09/19/2007 Project: Gateway Business Center Coppell, Texas Services: Structural Steel Inspection Structural Fram ing Location: 1. Bolt tension verification, 2nd floor framing assembly, building 1, grid lines A-E/1-18. 2. Visual weld verification, beam to column connection at beam web area, building 1, 2nd floor, grid lines A-E/1-18. 3. Visual weld verification, perimeter edge angle to cast-in-place embeds at tilt wall panels, interior, building 1, 2nd floor fram ing assem bly, grid lines A-E/1-18. Non Code Com pliant Com pliant AWS 01.1 AISC Job Specs Bolt Tension Verification: Beam to Beam (1) x x Job S p e c s IR F I Bolt Tension Verification: Beam to Colum n (1) x x Job S p e c s IR F I Bolt Tension Verification: Girder to Column (1) x x Job S p e c s IR F I Weld Profile (2,3) See note x See note x Job Specs WQT's Structural x x Job Specs Visual Touch-Up Paint Verification (3 ) x Job Specs Comments: Note: Visual weld verification of stair stringers to platform landing, not welded at all required locations. Re-work and follow-up re-inspection required. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMlJB) Page 2 of 5 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of Structural Steel Inspection Report No.: 606823 Project No.: 0712786 Date of Service: 09/12/2007 Report Date: 09/19/2007 Project: Gateway Business Center Coppell, Texas Services: Structural Steel Inspection Drawings Utilized: Approved contract drawings, approved RFI for field modifications, A W S D 1.12006 code specifications for visual weld verification AISC (American Institute Steel Construction) code specifications for bolt tension verification 1. Building 2, 2nd floor fram ing assem bly, bolt tension verification. 2. Building 2, visual weld verification of perimeter edge angle to cast-in-place em beds at tilt wall panels, 2nd floor. 3. Building 2, visual weld verification of stair fram ing assem bly. 4. Building 2, visual touch-up paint verification of field welds. 5. Building 2, anchor bolt tension verification. I. B 0 It ten s ion v e r i fie a t ion 0 f b u i 1 din g 2, 2 n d fl 0 0 r f ram in gas s e m b 1 y 1 S non- com pliant, due to the follow ing: a. Bolts not tensioned at all required locations. b. Missing bolts. c. At num erous locations, bolts are not LeJuned or TIC (tension splice not detached). d. Re-work and follow-up re-inspection required. Superintendent notified. II. V isual weld verification of perim eter edge angle to cast-in-place em beds at tilt wall panels, building 2 is non-compliant due to the following: a. At num erous locations, 2nd floor fram ing assem bly interior is not welded at required locations. b. Re-work and re-inspection required. Superintendent notified. III. Visualweld verification of stair framing assembly, building 2, ISland 2nd levels are non-compliant, due to the following: a. Not welded at stringers. b. Re-work and follow-up re-inspection required. Superintendent notified. IV. Visual touch-up paint verification offield welds at 2nd floor framing assembly, building 2 is non-compliant, due to the following: a. Numerous locations where field modifications were performed due to possible fabrication errors. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMIJB) Page 3 of 5 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of Structural Steel Inspection Report No.: 606823 Project No.: 0712786 Date of Service: 09/12/2007 Report Date: 09/19/2007 Project: Gateway Business Center Coppell, Texas Services: Structural Steel Inspection b. Welds not touch-up paInted. c. Perim eter edge angle to cast-in-place em beds (interior) not touch-up painted. d. Re-work and follow-up re-inspection required. Superintendent notified. V. Anchor bolt tension verification, building 2 is non-compliant, due to the following: a. Numerous locations not tensioned. b. Re-work and follow-up re-inspection required prior to construction cover up. Superintendent notified. LIMITATIONS The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/JB) Page 4 of 5 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of Ultrasonic Inspection Report No.: 606811 Project No.: 0712786 Date of Service: 09/07/2007 Report Date: 09/19/2007 Project: Gateway Business Center Coppell, Texas Services: Ultrasonic Inspection Report of Inspection Instrum ent/SN: C ertificatio n Date: Purpose of Test: Specification USN 52L 12/11/2006 Flow Detection AWS D1.1-06 Long. Freq./Size: 2.25 M HZ I 1.0" Shear Freq./Size: 2.25 M HZ I 5/B" 1700 Calibration: IIW & DSC Block Couplant: Cellulose Scan Sensitivity: 62 db's TestMethod N A I te m Q uantity U . T . Inspection Result 1 24 Top and b 0 tto m flange beam to co I u m n C ompliant moment connections atgrid Ii n e s 6 IB -D o f build in 9 1 and 9 rid Ii n e s 6 I B - D and 1 2 I B - D o f build in 9 2 o n 2 n d floor fram ing fo r both buildings. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/JB) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of Structural Steel Re-Inspection Report No.: 606824 Project No.: 0712786 Date of Service: 09/12/2007 Report Date: 09/19/2007 Project: Gateway Business Center Coppell, Texas Services: Structural Steel Re-Inspection Report of Re-Inspection L 0 c a ti 0 n : Bar J 0 is ts 1. Visual weld verification of peri meter edge angle to cast-in-place embeds attilt wall panels, roofframing assembly, exterior, building 1, grid lines A-E/1-18. Non Code Compliant o m P Ii a n AWS D 1 .1 S J I Job Specs Joist Seat Bearino VisualWeld Verification Horizontal Bridaino o iaoonal Bridoino Botto m Chord Stabilization JoistSoacino Perimeter Edoe Angle Weld V e r i fi cat ion (1 ,2 x x x x WQT's Structural x x IO.ws D 1 .1 2000 x VisualTouch-Up PaintVerification ofField Weld s (1 ,2) x x x Comments:Re-inspection, referencing primary Rone report#606737, dated 08/22/07. Item 1: Cleared to compliant status thru re-work and follow-up reinspection. 2. Visual weld verification re- inspection, perimeter edge angle to cast-in-place embeds, 2nd floor framing, building 1, interior, grid lines A-E/1-18, referencing Rone reports 606737, dated 08/22/07, and 606749 dated 08/23/07 are cleared to compliant status through re-work and follow-up re-inspection. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written appnoval of Rone Engineering Services, Ltd. (LB/JB) Page 1 of 3 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of Structural Steel Re-Inspection Report No.: 606824 Project No.: 0712786 Date of Service: 09/12/2007 Report Date: 09/19/2007 Project: Gateway Business Center Coppell, Texas Services: Structural Steel Re-Inspection She e IDe c k AlIa c h men I 10 S Iru c lu ra I F ra m in 9 Location. 1. Sheet deck re-inspection, building 1, roof fram ing assem bly, grid lines A-E/1-18. Referencing report #606737, dated 08/22/07, item 1, report #606749, dated 08123/07 Item 5 are cleared to com pliant status through re-work and follow-up re-inspection. 2. Sheet deck re-inspection, 2nd floor fram ing assem bly, rem aining partial, building 1, grid lines 7-9/C-E Com pliant status through re-work and follow-up re-inspection. 3. Nelson stud verification re-inspection, building 1, 2nd floor, rem aining partial, grid lines 7.9/C -E, referencing report #606796, dated 09/05107 Item 1 is cleared to com pliant status through re-w ark and follow .up re-inspection Non C ode C om n Ii a n t C o m p Ii a n I A W S D 1 .3 S D I Job Soecs V is u a I V e rific a tio n p u d d Ie W e Id s (1 ,2 I x x x J'o b Specs V IS U a I V e rific a tic n P ow d e rActuated V IS U a I V erification p n e u m a 1i c V isual Verification T e k S ere w s a I S ide Laps (1,2\ x x Job Specs S he e t D e c k M eehanieally Fastened w i I h S e If T a 0 pin a Sere w s S ide Lap s M eehanieallv C rim p e d (2) She e t Dee k In t e r i 0 r Altachm e n t Pallern 11,2' x x x Job Soees S he e t D e e k Peri m e te r Attaehm en t P a tie rn 1(1 ,2 , x x x Job Specs W Q T 's She e t S te e I x x x Job $Decs N e Is 0 n S lu d Verification P la e e m e n I (3 ) x x x Job S pee s V isualToueh-Up P aintVerlfication S h e e t D e e k P u d d Ie W e ld s (1 ,2 ) x x Job S pee s Comments L1MrrATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB/JB) Page 2 of 3 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 295839 Project No.: 0712786 Date of Service: 08/16/2007 Report Date: 09/19/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 136 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 33551501 Placement Date: 08/16/2007 Weather Conditions: Clear, warm Time Sampled: 11:15am Batch time: 10:34am Temperature - Air: 900F Concrete: 920F Truck No: NA Ticket No: 13694305 Air Content: 1.4% Unit Weight (pet): NA Overall Placement Location: Leave outs, building 1, grid lines A/1-2, Al6-9, E/1-5, A-E/1 Measured Slump (inches) 4.5 Sample Location: Leave out, building 1, grid line Al7.5 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 08/23/2007 7 6.00 28.27 111,170 3,930 Unbonded Cap 1 2 09/13/2007 28 6.00 28.27 142,600 5,040 Cone/Split 1 3 09/13/2007 28 6.00 28.27 137,660 4,870 Cone/Split Average 4,960 1 4 10/11/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM!LB) Page 1 of 2 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 296179 Project No.: 0712786 Date of Service: 08/20/2007 Report Date: 09/19/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Constructors & Associates Concrete Supplier: Redi Mix Plant: 136 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Batch time: 12:52pm Concrete: 970F Ticket No: 13694648 Unit Weight (pet): NA Measured Slump (inches) 4.0 Mix Design I.D.: 830J1521 Placement Date: 08/20/2007 Weather Conditions: Clear Time Sampled: 01:30pm Temperature - Air: 920F Truck No: 1186 Air Content: 4.2% Overall Placement Location: Grade beam on south side of buildings 1 and 2, grids on building 1 - 7.5 to 10.0, line F Sample Location: Grid line F.0/6.S REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 08/27/2007 7 6.00 28.27 98,300 3,480 Unbonded Cap 1 2 09/17/2007 28 6.00 28.27 132,340 4,680 Shear 1 3 09/17/2007 28 6.00 28.27 128,330 4,540 Cone/Split Average 4,610 1 4 10/15/2007 56 Remarks: Water added at site: 10 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written appnoval of Rone Engineering Services, Ltd. (CH/LB) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of Reinforcing Steel Inspection Report No.: 298349 Project No.: 0712786 Date of Service: 09/11/2007 Report Date: 09/19/2007 Project: Gateway Business Center Coppell, Texas Services: Reinforcing Steel Inspection Report of Inspection Locations and Items Inspected: Build ing slab, wire m es h, 9 rid lines 1.0-18. O/A. O-E .0. Item s Inspected: Co nfo rm ing Non Items Inspected: Co nfo rm ing Non Items Inspected: Conforming Non Co nfo rm ing Conforming Conforming P lacing Drawings Bar Length Column Ties Properly Appro ved x and Shape x Tied and Spaced NA Bar Size x Proper B ar Placement x Stirrup Spacing NA Bar Grade x Pro perly Tied x Stirrup Type NA Bars Clean x Dowel Bars in Place x Lapped Splices x F 0 rrn Clean x Proper Bar Supports x Co mer 8 ars NA NumberofBars x Pro per Cover x Mechanical Splices NA Discrepancies / Comments: 1. Remove loose debris from placement area. Discrepancies noted above were corrected prior to concrete placement. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 1 of 2