Loading...
Gateway BP(3.1)-LR070926 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 298513 Project No.: 0712786 Date of Service: 09/13/2007 Report Date: 09/26/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Constructors & Associates Concrete Supplier: Redi Mix Plant: 259 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Batch time: 02:52am Concrete: 810F Ticket No: 59013602 Unit Weight (pcf): NA Measured Slump (inches) 4.5 Mix Design I.D.: 330J1501 Placement Date: 09/13/2007 Weather Conditions: Cloudy Time Sampled: 03:30am Temperature - Air: 750F Truck No: 1140 Air Content: 1.5% Overall Placement Location: Slab, 2nd level building 1, grid line 1st pour: A-E, 12-18, grid line 2nd pour: A-E, 1-6 Sample Location: Grid line A.5-12.3, 2nd level REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 09/17/2007 4 6.00 28.27 95,060 3,360 Shear 2 10/11/2007 28 3 10/11/2007 28 4 11/08/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 1 of 6 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 298513 Project No.: 0712786 Date of Service: 09/13/2007 Report Date: 09/26/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Constructors & Associates Concrete Supplier: Redi Mix Plant: 259 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM (;-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 5.75 Mix Design 1.0.: 330J1501 Placement Date: 09/13/2007 Weather Conditions: Mostly cloudy Time Sampled: 05:00am Batch time: 04:25am Temperature - Air: 740F Concrete: 820F Truck No: 1321 Ticket No: 59013610 Air Content: 1.6% Unit Weight (pct): NA Overall Placement Location: Slab, 2nd level building 1, grid line 1 st pour: A-E, 12-18, grid line 2nd pour: A-E, 1-6 Sample Location: Grid line B.9-17.5, 2nd level REPORT OF TESTS Cylinder Marked Date Set No. Tested 2 1 09/17/2007 2 2 10/11/2007 2 3 10/11/2007 2 4 11/08/2007 Age (days) 4 Diameter (in) 6.00 28 28 56 Remarks: Water added at site: 5 gallons Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 80,840 Compressive Strength (psi) 2,860 Fracture Type Cone/Split Area (in2) 28.27 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exdusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 2 of 6 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 298513 Project No.: 0712786 Date of Service: 09/13/2007 Report Date: 09/26/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Constructors & Associates Concrete Supplier: Redi Mix Plant: 259 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 5.75 Mix Design I.D.: 330J1501 Placement Date: 09/13/2007 Weather Conditions: Mostly cloudy Time Sampled: 07: 15am Batch time: 06:28am Temperature - Air: 750F Concrete: 830F Truck No: 1299 Ticket No: 59013624 Air Content: 1.6% Unit Weight (pet): NA Overall Placement Location: Slab, 2nd level building 1, grid line 1 st pour: A-E, 12-18, grid line 2nd pour: A-E, 1-6 Sample Location: Grid line 0.5-13.5, 2nd level REPORT OF TESTS Cylinder Marked Date Set No. Tested 3 1 09/17/2007 3 2 10/11/2007 3 3 10/11/2007 3 4 11/08/2007 Age (days) 4 Diameter (in) 6.00 28 28 56 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 74,470 Compressive Strength (psi) 2,630 Fracture Type Shear Area (in') 28.27 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/tWV) Page 3 of 6 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 298513 Project No.: 0712786 Date of Service: 09/13/2007 Report Date: 09/26/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Constructors & Associates Concrete Supplier: Redi Mix Plant: 259 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 5.75 Mix Design 1.0.: 330J1501 Placement Date: 09/13/2007 Weather Conditions: Mostly cloudy Time Sampled: 11 :OOam Batch time: 10:03am Temperature - Air: 800F Concrete: 850F Truck No: 1321 Ticket No: 59013653 Air Content: 1.2% Unit Weight (pcf): NA Overall Placement Location: Slab, 2nd level building 1, grid line 1 st pour: A-E, 12-18, grid line 2nd pour: A-E, 1-6 Sample Location: Grid line A.7-2.5, 2nd level REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 71,050 Cylinder Marked Date Set No. Tested 4 1 09/17/2007 4 2 10/11/2007 4 3 10/11/2007 4 4 11/08/2007 Age (days) 4 Diameter (in) 6.00 28 28 56 Remarks: Water added at site: 5 gallons Area (in') 28.27 Compressive Strength (psi) 2,510 Fracture Type Cone/Split LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 4 of 6 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 298513 Project No.: 0712786 Date of Service: 09/13/2007 Report Date: 09/26/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Constructors & Associates Concrete Supplier: Redi Mix Plant: 259 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 5.0 Mix Design I.D.: 330J1501 Placement Date: 09/13/2007 Weather Conditions: Mostly cloudy Time Sampled: 01:25pm Batch time: 12:45pm Temperature - Air: 890F Concrete: 880F Truck No: 1211 Ticket No: 59013680 Air Content: 1 .7% Unit Weight (pet): NA Overall Placement Location: Slab, 2nd level building 1, grid line 1st pour: A-E, 12-18, grid line 2nd pour: A-E, 1-6 Sample Location: Grid line D.5-4.9, 2nd level REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 5 1 09/17/2007 4 6.00 28.27 81 ,600 2,890 Shear 5 2 10/11/2007 28 5 3 10/11/2007 28 5 4 11/08/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibiiity for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 5 of 6 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8906 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 298818 Project No.: 0712786 Date of Service: 09/15/2007 Report Date: 09/26/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Constructors & Associates Concrete Supplier: LMC Plant: 7 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 2" - 4" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 1551 Placement Date: 09/15/2007 Weather Conditions: Sunny Time Sampled: 08:35am Temperature - Air: 700F Truck No: 7025 Air Content: 4.5% Overall Placement Location: Inlets - 3 total at Stations 2+91, 7+00 and 9+18 Sample Location: Station 7+00 REPORT OF TESTS Batch time: 07: 18am Concrete: 840F Ticket No: 7182253 Unit Weight (pct): NA Measured Slump (inches) 4.0 Cylinder Marked Date Set No. Tested 1 1 09/22/2007 1 2 10/13/2007 1 3 10/13/2007 4 11/10/2007 Age (days) 7 Diameter (in) 6.00 28 28 56 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 99,900 Area (in') 28.27 Compressive Strength " (psi) ~,530 Fracture Type Cone/Split LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 1 of 2