Duke Lesley 2A-LR070927 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 297067 Project No.: 0712932 Date of Service: 08/28/2007 Report Date: 09/27/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 01 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): NA Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7751 PW Placement Date: 08/28/2007 Weather Conditions: Partly cloudy Time Sampled: 03:40pm Batch time: 03:06pm Temperature - Air: 990F Concrete: 920F Truck No: 101 Ticket No: 13229 Air Content: NA Unit Weight (pct): NA Overall Placement Location: Piers (see report #297066) Measured Slump (inches) 6.5 Sample Location: Pier Jf13 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 09/04/2007 7 6.00 28.27 80,830 2,860 Shear 1 2 09/04/2007 7 6.00 28.27 84,730 3,000 Shear Average 2,930 1 3 09/25/2007 28 6.00 28.27 108,060 3,820 Shear 1 4 09/25/2007 28 6.00 28.27 112,770 3,990 Shear Average 3,910 1 5 10/23/2007 56 Technician: Chris Harbour Rone Engineering See Report 297066 for technician time~~ Report Distribution: '. .' ~ Od" ~":~ :':p~~truct;oo. LP (D."". TX) Att"' M'. p", ",me: . . ".". ... ... ~ 1-cc Potter Concrete Attn: Mr. Ryan Skelly K. Scott Watson, AET 1-cc City of Coppell Attn: Mr. Lee Stone. Project Manager 1-cc City of Coppell Attn: Mr. Larry DaVIS LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/LB) Page 1 of 1 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7101 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 296867 Project No.: 0712932 Date of Service: 08/25/2007 Report Date: 09/27/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 01 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): NA Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 7751 PW Placement Date: 08/25/2007 Weather Conditions: Clear Time Sampled: 1 0:40am Temperature - Air: 910F Truck No: 103 Air Content: NA Overall Placement Location: Piers (see report #296866) Batch time: 10:06am Concrete: 920F Ticket No: 13189 Unit Weight (pcf): NA Measured Slump (inches) 5.75 Sample Location: Pier E/1 0 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 09/01/2007 7 6.00 28.27 95,230 3,370 Unbonded Cap 1 2 09/01/2007 7 6.00 28.27 90,020 3,180 Unbonded Cap Average 3,280 3 09/22/2007 28 6.00 28.27 124,750 4,410 Cone/Split 4 09/22/2007 28 6.00 28.27 122,130 4,320 Cone/Split Average 4,370 5 10/20/2007 56 Technician: Chris Harbour Rone Engineering See Report 296866 for technician time~ ~ Report Distribution: . . . ~ ~ Ori9' ~":: ~::~t,"d~". LP (D.,,",. TX) An" Me P,"' By", " ' . - -" =---' 1-cc Potter Concrete AUn: Mr. Ryan Skelly K. Scott Watson, AET 1-cc City of Coppell AUn: Mr. Lee Stone p . t M .' rOJec anager 1-cc City of Coppell AUn: Mr. Larry DaVIS LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMILB) Page 1 of 1 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Com pressive Strength Test Report No.: 296710 Project No.: 0712932 Date of Service: 08/24/2007 Report Date: 09/27/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 01 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): NA Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7751 PW Placement Date: 08/24/2007 Weather Conditions: Partly Cloudy Time Sampled: 12:30pm Batch time: 11:50am Temperature - Air: 990F Concrete: 950F Truck No: 119 Ticket No: 13165 Air Content: NA Unit Weight (pct): NA Overall Placement Location: Piers (see report #296709) Measured Slump (inches) 6.0 Sample Location: Pier JIB REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 08/31/2007 7 6.00 28.27 85,820 3,040 Unbonded Cap 1 2 08/31/2007 7 6.00 28.27 81,710 2,890 Unbonded Cap Average 2,960 1 3 09/21/2007 28 6.00 28.27 121,640 4,300 Cone/Split 1 4 09/21/2007 28 6.00 28.27 114,890 4,060 Cone/Split Average 4,180 5 10/19/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, ltd. (LB/LB) Page 1 of 2 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 296710 Project No.: 0712932 Date of Service: 08/24/2007 Report Date: 09/27/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 01 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): NA Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7751 PW Placement Date: 08/24/2007 Weather Conditions: Partly Cloudy Time Sampled: 04:38pm Batch time: 04:18pm Temperature - Air: 101 of Concrete: 930F Truck No: 127 Ticket No: 13179 Air Content: NA Unit Weight (pet): NA Overall Placement Location: Piers (see report #296709) Measured Slump (inches) 6.5 Sample Location: Pier J/9 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 2 1 08/31/2007 7 6.00 28.27 90,680 3,210 Unbonded Cap 2 2 08/31/2007 7 6.00 28.27 91,930 3,250 Unbonded Cap Average 3,230 2 3 09/21/2007 28 6.00 28.27 119,380 4,220 Shear 2 4 09/21/2007 28 6.00 28.27 120,500 4,260 Cone/Split Average 4,240 2 5 10/19/2007 56 Technician: Chris Harbour Rone Engineering See Report 296709 for technician time~~ Report Distribution: o""~: ~~~~t'"ct;'" LP (D'''"" TX) Att" M,. p", Byme , . .' ... " ~u' ~ 1-cc Potter Concrete Attn: Mr. Ryan Skelly K. Scott Watson, AET 1-cc City of Coppell Attn: Mr. Lee Stone Project Manager 1-cc City of Coppell Attn: Mr. Larry Davis ~ LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (lB/lB) Page 2 of 2 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630.9745 Report of Concrete Compressive Strength Test Report No.: 296910 Project No.: 0712932 Date of Service: 08/27/2007 Report Date: 09/27/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 01 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): NA Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7751PW Placement Date: 08/27/2007 Weather Conditions: Clear Time Sampled: 1 0:40am Temperature - Air: 980F Truck No: 120 Air Content: NA Overall Placement Location: Piers (see report #296909) Batch time: 10:20am Concrete: 920F Ticket No: 13196 Unit Weight (pet): NA Measured Slump (inches) 5.5 Sample Location: Pier F/11 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 1 1 09/03/2007 7 6.00 28.27 87,630 3,100 Unbonded Cap 1 2 09/03/2007 7 6.00 28.27 85,840 3,040 Unbonded Cap Average 3,070 1 3 09/24/2007 28 6.00 28.27 108,140 3,820 Cone/Split 1 4 09/24/2007 28 6.00 28.27 113,590 4,020 Cone/Split Average 3,920 5 10/22/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMILB) Page 1 of 2 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 296910 Project No.: 0712932 Date of Service: 08/27/2007 Report Date: 09/27/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 01 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): NA Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7751 PW Placement Date: 08/27/2007 Weather Conditions: Partly cloudy Time Sampled: 03:43am Batch time: 03:20am Temperature - Air: 1000F Concrete: 950F Truck No: 120 Ticket No: 13210 Air Content: NA Unit Weight (pet): NA Overall Placement Location: Piers (see report #296909) Measured Slump (inches) 6.75 Sample Location: Pier E/12 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 2 1 09/03/2007 7 6.00 28.27 91,650 3,240 Unbonded Cap 2 2 09/03/2007 7 6.00 28.27 92,990 3,290 Unbonded Cap Average 3,270 2 3 09/24/2007 28 6.00 28.27 121,640 4,300 Shear 2 4 09/24/2007 28 6.00 28.27 131,310 4,640 Shear Average 4,470 2 5 10/22/2007 56 Technician: Chris Harbour Rone Engineering See Report 296909 for technician time'p ~ Report Distribution: ~ ~ 0'" ~~~ ~p~;truct;oo. tp (0''',". TX) Att" M" P,"' Bym. " - - ., , ,:' ---- ~ ~ 1-cc Potter Concrete Attn: Mr. Ryan Skelly K. Scott Watson AET 1-cc City of Coppell Attn: Mr. Lee Stone p . t M ' 1-cc City of Coppell Attn: Mr. Larry Davis rOJee anager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility forvariation in quality (composition, appearance, etc.) or any other feature of similar SUbject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exciusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/LB) Page 2 of 2 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 296555 Project No.: 0712932 Date of Service: 08/23/2007 Report Date: 09/27/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 01 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): NA Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7751 PW Placement Date: 08/23/2007 Weather Conditions: Partly cloudy Time Sampled: 11 :05am Batch time: 09:53am Temperature - Air: 930F Concrete: 910F Truck No: 140 Ticket No: 13140 Air Content: NA Unit Weight (pet): NA Overall Placement Location: Piers (see report #296554) Measured Slump (inches) 6.0 Sample Location: Pier H/6 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 1 1 08/30/2007 7 6.00 28.27 71,750 2,540 Unbonded Cap 1 2 09/20/2007 28 6.00 28.27 100,790 3,560 Cone/Split 1 3 09/20/2007 28 6.00 28.27 95,630 3,380 Cone/Shear Average 3,470 1 4 10/18/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/LB) Page 1 of 2 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 296555 Project No.: 0712932 Date of Service: 08/23/2007 Report Date: 09/27/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 01 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): NA Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 7751 PW Placement Date: 08/23/2007 Weather Conditions: Partly cloudy Time Sampled: 04:35pm Batch time: 03:58pm Temperature - Air: 990F Concrete: 980F Truck No: 140 Ticket No: 13157 Air Content: NA Unit Weight (pet): NA Overall Placement Location: Piers (see report #296554) Measured Slump (inches) 6.5 Sample Location: Pier B/7 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 2 1 08/30/2007 7 6.00 28.27 85,600 3,030 Unbonded Cap 2 2 09/20/2007 28 6.00 28.27 112,620 3,980 Cone/Split 2 3 09/20/2007 28 6.00 28.27 117,250 4,150 Cone/Split Average 4,060 2 4 10/18/2007 56 Technician: Chris Harbour Rone Engineering See Report 296554 for technician time~ ~ Report Distribution: ~ ',' ' Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne ,,' ", ,',' " ' (1-ec copy) 1-cc Potter Concrete Attn: Mr. Ryan Skelly K. Scott Watson, AET 1-cc City of Coppell Attn: Mr. Lee Stone. Project Manager 1-cc City of Coppell Attn: Mr. Larry DaVIS ~ LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exciusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMlLB) Page 2 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Reinforcing Steel Inspection Report No.: 299647 Project No.: 0712932 Date of Service: 09/22/2007 Report Date: 09/27/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Reinforcing Steel Inspection Report of Inspection Locations and Items Inspected: Building pad, slab on grade, grid lines 1,1-11/G-J, Items Inspected: Conforming Non Items Inspected: Conforming Non Items Inspected: co nfo rm ing Non Conforming Conforming Conforming Placing 0 rawings Bar Length ColumnTies Properly Approved x and Shape x Tied and Spaced NA Bar Size x Pro per Bar P lacem ent x Stirrup Spacing NA Bar Grade x Properly Tied x Stirrup Type NA Bars Clean x Dowel Bars in Place x Lapped Splices x Form Clean x Proper B ar Suppo rts NA Co mer Bars NA Numberof Bars x Pro per Co ver NA Mechanical Splices NA Discrepancies I Comments: No apparent discrepancies were noted at the locations listed above. Note: Chairs were added during placement. Technician: Chris Harbour Started: 07: 15am Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne (1-ec copy) 1-cc City of Coppel! Attn: Mr. Lee Stone 1-cc City of Coppel! Attn: Mr. Larry Davis Finished: 09:30am Rone Engineering ~~.~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMfLB) Page 1 of 1 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 299737 Project No.: 0712932 Date of Service: 09/24/2007 Report Date: 09/27/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Duke Construction, LP Test Method: ASTM D-6938 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 735 Current: 2507 Previous: 742 Previous: 2510 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements MID No. Description % (pct) Moisture Density 272998 Brown I Silty Clay wI Organics 22.5 96.5 Optimum +4 95min FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (% max) Utility backfill Water line W-1, Station 22+22,3' below grade 4" 272998 25.8 116.2 92.4 96 Utility backfill 2 Water line W-1, Station 22+22, 2' below grade 4" 272998 23.1 116.3 94.5 98 Utility backfill 3 Water line W-1, Station 22+22, l' below grade 4" 272998 24.5 116.8 93.8 97 Utility backfill 4 Water line W-1, Station 22+22, grade 4" 272998 24.7 116.0 93.0 96 Utility backfill 5 Water line W-1, Station 17+43,3' below grade 4" 272998 24.2 115.9 93.3 97 Utility backfill 6 Water line W-1, Station 17+43, 2' below grade 4" 272998 23.1 117.9 95.8 99 Utility backfill 7 Water line W-1, Station 17+43, l' below grade 4" 272998 24.7 117.5 94.2 98 Utility backfill 8 Water line W-1, Station 17+43, grade 4" 272998 22.9 117.2 95.4 99 Utility backfill 9 Water line W-1 , Station 14+43, 3' below grade 4" 272998 25.3 114.8 91.6 95 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar sUbject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/LB) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 299737 Project No.: 0712932 Date of Service: 09/24/2007 Report Date: 09/27/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (%max) - Utility backfill 10 Water line W-1, Station 14+43,2' below grade 4" 272998 23.8 116.0 93.7 97 Utility backfill 11 Water line W-1, Station 14+43, l' below grade 4" 272998 24.3 116.3 93.6 97 Utility backfill 12 Water line W-1, Station 14+43, grade 4" 272998 24.5 115.9 93.1 97 Utility backfill 13 Water line W-1, Station 6+41, 3' below grade 4" 272998 23.8 116.0 93.7 97 Utility backfill 14 Water line W-1, Station 6+41, 2' below grade 4" 272998 24.8 114.9 92.1 95 Utility backfill 15 Water line W-1, Station 6+41, l' below grade 4" 272998 24.1 116.4 93.8 97 Utility backfill 16 Water line W-1, Station 6+41, grade 4" 272998 22.6 116.1 94.7 98 Utility backfill 17 Water line W-1, Station 5+67, 3' below grade 4" 272998 24.2 116.4 93.7 97 Utility backfill 18 Water line W-1, Station 5+67, 2' below grade 4" 272998 24.8 115.3 92.4 96 Utility backfill 19 Water line W-1, Station 5+67, l' below grade 4" 272998 25.5 115.8 92.3 96 Utility backfill 20 Water line W-1, Station 5+67, grade 4" 272998 22.8 115.7 94.2 98 Utility backfill 21 Water line W-1, Station 1 +15, 3' below grade 4" 272998 24.7 115.2 92.4 96 Utility backfill 22 Water line W-1, Station 1 +15, 2' below grade 4" 272998 24.1 114.8 92.5 96 Utility backfill 23 Water line W-1, Station 1+15, l' below grade 4" 272998 24.1 115.2 92.8 96 Utility backfill 24 Water line W-1, Station 1 +15, grade 4" 272998 26.0 115.2 91.4 95 Technician: Joe Jernigan Started: 10:00am Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne (1-ec copy) 1-cc City of Coppell Attn: Mr. Lee Stone 1-cc City of Coppell Attn: Mr. Larry Davis Finished: 11 :30am Rone Engineering P-~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/LB) Page 2 of 2