Northlake College-LR071004
KLEINFELDER
TO:
2211 Century Center Blvd., Suite 101, Irving, Texas 75062
972-870-0808 Metro 972-953-0398 Fax 972-870-0802
4x8 CONCRETE CYLINDER CO~SSIVE STRENGTH REPORT
Dallas County Community College Dist. ""..- PROJECT: North Lake College, N Campus
1505 South Lamar, Suite 1015 W Sandy Lake Road @ SH 121
Dallas, Texas 75215 PROJECT NO: 87015
TECHNICIAN: J. Mayo
REPORT DATE: 10/4/2007
REPORT NO: 097107
Page 1 of 2
CONCRETE FOR: Drilled shaft C-18, C.2-17, C.2-15, C.2-13, C.2-11 and C-9
097107
097107B
097107C
0971070
DATE DATE AVG. CYLINDER CYLINDER FRACTURE TOTAL
CAST TESTED DIAMETER, IN. AREA, IN.2 TYPE LOAD, LBS
9/27/07 10/4/07 4.00 12.57 N/A 36,980
9/27/07 10/25/07
9/27/07 10/25/07
9/27/07 HOLD
CYLINDER
MARK
TRUCK NO. :
TICKET NO. :
ACCUMULATED YDS :
TIME CAST:
TIME IN TRUCK:
WEATHER:
103
1098513
1 0 of 10
1 :37 PM
37 min
Clear
AVERAGE 28 DAY STRENGTH:
28 DAY STRENGTH REQUIREMENT: 3,000
SUPPLIER: Southern Star
MIX DESIGN: D00000007781
ADDITIONAL INFORMATION IF MADE BY KL
SPECIFIED
FRACTURE TYPES:
1 Reasonably well-formed cones on both ends, less than 1 in. (25 mm) of cracking through caps.
2 Well-formed cone on one end, vertical cracks running through caps, no well-defined cone on other end.
3 Columnar vertical cracking through both ends, no well-formed cones.
4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type 1.
5 Side fractures at top or bottom (occur commonly with un bonded caps).
6 i il T 5 n f lin r i in
NOTES: . Compressive strengths determined in accordance with ASTM C39. . Cross-sectional area, diameter and length are standard unless otherwise noted.
. Portions of the information contained in this report have been furnished by others. . Cylinders cured in laboratory in accordance with ASTM C31 unless
otherwise noted. . Unbonded caps utilized in accordance with ASTM C1231 unless otherwise noted. Because of the violent release of energy stored in pads,
the broken cylinder rarely exhibits conical fracture typical of capped cylinders and the sketches of types of fracture in Test Method C39 are not descriptive.
. Samples taken in accordance with ASTM C172 where practicable. When applicable, the following test procedures were used: Slump ASTM C143;
Unit Weight ASTM C138; Air Content ASTM C173/ C231; Temperature ASTM C1064
Reports to:
Starling Richardson Const.; Attn: Eric Stanaland (eps@starlingrichardson.com)
Starling Richardson Const.; Attn; Andy Munoz (amunoz@starlingrichardson.com)
DCCCD Bond Office; Attn: Brenda Spinelli (brenda.spinelli@dcccd.edu)
DCCCD Bond Office; Attn: James Williams Qames.williams@dcccdedu)
DCCCD Bond Office; Attn: Mike Daniels (mike.daniels@dcccd.edu)
Jacobs; Attn: Andrea Stogner (Andrea.stogner@jacobs.com)
Jacobs; Attn: Jennifer Blount (Jennifer.blount@jacobs.com)
1- City of Coppell; Attn: Larry Davis
1- City of Coppell; Attn: Lee Stone
The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or Inspected. They are not intended to be
indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety.
KLEINFELDER
/1
KLEINFELDER
2211 Century Center Blvd., Suite 101, Irving, Texas 75062
972-870-0808 Metro 972-953-0398 Fax 972-870-0802
4x8 CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT
TO: Dallas County Community College Dist.
1505 South Lamar, Suite 1015
Dallas, Texas 75215
PROJECT: North Lake College, N Campus
W Sandy Lake Road @ SH 121
PROJECT NO: 87015
TECHNICIAN: J. Mayo
CONCRETE FOR: Drilled shaft G-19, 8-17, 8-15, 8-13 and 8-11
REPORT DATE: 10/4/2007
REPORT NO: 097107
Page 2 of 2
CYLINDER DATE DATE AVG. CYLINDER CYLINDER FRACTURE TOTAL
MARK CAST TESTED DIAMETER, IN. AREA,IN.2 TYPE LOAD, LBS
097108A 9/27/07 10/4/07 4.00 12.57 5 32,760
0971088 28 9/27/07 10/25/07
097108C 28 9/27/07 10/25/07
0971080 HOLD 9/27/07 HOLD
SUPPLIER: Southern Star
MIX DESIGN: 000000007781
ADDITIONAL INFORMATION IF MADE BY KLEINFELDER:
AVERAGE 28 DAY STRENGTH:
28 DAY STRENGTH REQUIREMENT: 3,000
TRUCK NO. :
TICKET NO. :
ACCUMULATED YDS:
TIME CAST:
TIME IN TRUCK:
WEATHER:
1071
1098771
26 of 26
4:53 PM
58 min
Clear
SLUMP:
AIR TEMP. :
MIX TEMP.:
AIR CONTENT:
WATER ADDED (gal):
UNIT WEIGHT:
ACTUAL
6.25
90
98
N/A
o
N/A
SPECIFIED
FRACTURE TYPES:
1 Reasonably well-formed cones on both ends, less than 1 in. (25 mm) of cracking through caps.
2 Well-fonmed cone on one end, vertical cracks running through caps, no well-defined cone on other end.
3 Columnar vertical cracking through both ends. no well-formed cones.
4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type 1
5 Side fractures at top or bottom (occur commonly with unbonded caps).
6 im'l r T n f tin r i in
NOTES: . Compressive strengths determined in accordance with ASTM C39. . Cross-sectionai area, diameter and length are standard unless otherwise noted.
. Portions of the information contained in this report have been furnished by others. . Cylinders cured in laboratory in accordance with ASTM C31 unless
otherwise noted. . Unbonded caps utilized in accordance with ASTM C1231 unless otherwise noted. Because of the violent release of energy stored in pads,
the broken cylinder rarely exhibits conical fracture typical of capped cylinders and the sketches of types of fracture in Test Method C39 are not descriptive.
. Samples taken in accordance with ASTM C172 where practicable. . When applicable, the following test procedures were used: Slump ASTM C143;
Unit Weight ASTM C138; Air Content ASTM C173/ C231; Temperature ASTM C1064
Reports to:
Starling Richardson Const.; Attn: Eric Stanaland (eps@starlingrichardson.com)
Starling Richardson Const.; Attn: Andy Munoz (amunoz@starlingrichardson.com)
DCCCD Bond Office; Attn: Brenda Spinelli (brenda.spinelli@dcccd.edu)
DCCCD Bond Office; Atln: James Williams Uames.williams@dcccd.edu)
DCCCD Bond Office; Atln: Mike Daniels (mike.daniels@dcccd.edu)
Jacobs; Atln: Andrea Stogner (Andrea.stogner@jacobs.com)
Jacobs; Atln: Jennifer Blount (Jennifer.blount@jacobs.com)
1- City of Coppell; Atln: Larry Davis
1- City of Coppell; Atln: Lee Stone
The results shown on this report are for the exclusive use of the client for wham they were obtained and apply only to the samples tested and/or inspected. They are not intended to be
indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety.
KLEINFELDER
Joel Peters, P.E.