Loading...
Duke Lesley 3C-LR070926 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 298904 Project No.: 0711530 Date of Service: 09/17/2007 Report Date: 09/26/2007 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 5" - 7" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7151 PW Placement Date: 09/17/2007 Weather Conditions: Sunny Time Sampled: 10:20am Temperature - Air: 860F Truck No: 134 Air Content: NA Overall Placement Location: Point West One, F.8/01 Pier Batch time: 09:33am Concrete: 820F Ticket No: 7401 Unit Weight (pet): NA Measured Slump (inches) 6.0 Sample Location: Pier F.8/01 REPORT OF TESTS Cylinder Marked Set No. - - 1 1 Date Tested 09/24/2007 Age (days) 7 Diameter (in) 6.00 1 1 2 3 10/15/2007 10/15/2007 28 28 -L- 4 11/12/2007, J . .~ . 56 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 97,590 Compressive Strength (psi) 3,450 Fracture Type Cone/Split Area (in2) 28.27 Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: (1-ec copy) 1-cc Potter Concrete Attn: Mr. Ryan Skelly 1-cc City of Coppell Attn: Mr. Lee Stone 1-cc City of Coppell Attn: Mr. Larry Davis Rone Engineering sreReport298872fmte'h';';aot;me~....... .~ ~.." .... . Mr. Paul Byrne . K. Scott Watson, AET Project Manager Technician: Denny Harris ~ LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/LB) Page 1 of 1 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 298873 Project No.: 0711530 Date of Service: 09/17/2007 Report Date: 09/26/2007 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 3,500 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7752 PW Placement Date: 09/17/2007 Weather Conditions: Sunny Time Sampled: 08:30am Temperature - Air: 840F Truck No: 134 Air Content: NA Overall Placement Location: East and west approach off Dividend Batch time: 07:51am Concrete: 820F Ticket No: 7396 Unit Weight (pet): NA Measured Slump (inches) 6.0 Sample Location: East and west approach off Dividend REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 85,950 Cylinder Marked Date Age Diameter Area Set No. Tested (days) (in) (in') 1 1 09/24/2007 7 6.00 28.27 1 2 10/15/2007 28 1 3 10/15/2007,- 28 ~ 1 4 11/12/200I~ 56 fJ " ,. Technician: Denny Harris Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne (1-ec copy) 1-cc Potter Concrete Attn: Mr. Ryan Skelly 1-cc City of Coppell Attn: Mr. Lee Stone 1-cc City of Coppell Attn: Mr. Larry Davis Compressive Strength (psi) 3,040 Fracture Type Cone/Shear ;".-. Rone Engineering ft~.~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/LB) Page 1 of 1