Alexander Ct-LR071012 I~A TESTING, INe. 2209 Wisconsin St., Suite 700 Dallas, Texas 75229 972/620-8977 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR: Mira Mar Development Corporation Colleyville, Texas DATE: 10/12/07 PROJECT: Alexander Court Cappell, Texas OUR REPORT NO.: 070021-9 TEST DATA: TEST ~ SOIL 10 OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT' NO. % PCF % PCF 49 10/12/07 FG-2.0 3 13.0 115.4 14.8 111 I 96 1-A 50 10/12/07 FG-1.0 3 13.0 115.4 15.6 111 96 1-A I 51 10/12/07 FG 3 13.0 115.4 13.4 113 i 98 1-A 52 10/12/07 FG-2.0 3 13.0 115.4 13.8 112 1 97 1-A j 53 10/12/07 FG-1.0 3 13.0 115.4 14.7 112 \ 97 1-A 54 10/12/07 FG 3 13.0 115.4 14.0 114 99 1-A 55 10/12/07 FG-2.0 3 13.0 115.4 14.5 113 98 1-A TEST LOCATION: BUILDING PADS 49 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 16 50 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 16 51 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 16 52 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 17 53 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 17 54 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 17 55 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 18 1 FILL 2 NATURALSUBGRADE 3 LIME STABILIZED 4 CEMENT TREATED . A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS o RETEST Respectfully Submitted. ~ffL-- Tom Ellis ALPHA TESTING, INC. Our test results and reports are for the exclUSIve use of the Client (and thell deSignated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently Identical or simjlar specimens Geotechnical Engineering & Construction Materials Testing & Environmental Engineering & Consulting I~A TESTING. INe. 2209 Wisconsin St., Suite 100 Do/los. Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR: Mira Mar Development Corporation Colleyville, Texas DATE: 10/12/07 PROJECT: Alexander Court Coppell, Texas OUR REPORT NO.: 070021-9A TEST DATA: TEST ~ SOIL 10 OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT DATE MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT" NO. DEPTH NUMBER % PCF % PCF COMPACTION " 56 10/12/07 FG-1.0 3 13.0 115.4 12.8 114 99 1-A 1 10/12/07 FG 3 13.0 115.4 13.6 115 , 100 1-A 57 : 58 10/12/07 FG-2.0 3 13.0 115.4 14.2 116 100 1-A 59 10/12/07 FG-1.0 3 13.0 115.4 14.7 112 97 1-A 60 10/12/07 FG 3 13.0 115.4 14.5 111 96 1-A 61 10/12/07 FG-2.0 3 13.0 115.4 13.6 112 97 1-A 62 10/12/07 FG-1.0 3 13.0 115.4 13.6 113 98 1-A TEST LOCATION: BUILDING PADS 56 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 18 57 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 18 58 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 19 59 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 19 60 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 19 61 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 20 62 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 20 1 FILL 2. NATURAL SUBGRADE 3 LIME STABILIZED 4 CEMENT TREATED . A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS o RETEST Respectfully Submitted. ~~ Tom Ellis ALPHA TESTING. INC OUf test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall nat be reproduced and/or distributed except with express approval of ALPHA The use of our name and test resulls must receive our wrilten approval Test results and reports apply only to the samples tested and/or observed. and are not indicative of the qualities of apparently Identical or similar specimens Geotechnical Engineering & Construction Materials Testing & Environmental Engineering & Consulting '~A TESTING. INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR: Mira Mar Development Corporation Colleyville, Texas DATE: 10/12/07 PROJECT: Alexander Court Coppell, Texas OUR REPORT NO.: 070021-9B TEST DATA: TEST ~ SOIL 10 OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT DATE MOISTURE ORY DENSITY MOISTURE DRY DENSITY COMMENT' NO. DEPTH NUMBER % PCF % PCF COMPACTION 63 10/12/07 FG 3 13.0 115.4 14.8 116 \ 101 1-A \ 64 10/12/07 FG-2.0 3 13.0 115.4 14.1 115 I 99 1-A i 65 10/12/07 FG-1.0 3 13.0 115.4 13.6 115 100 1-A 66 10/12/07 FG 3 13.0 115.4 14.5 113 98 1-A 67 10/12/07 FG-2.0 3 13.0 115.4 16.2 112 97 1-A / 68 10/12/07 FG-1.0 3 13.0 115.4 15.2 111 , 96 1-A 69 10/12/07 FG 3 13.0 115.4 15.8 111 96 1-A TEST LOCATION: BUILDING PADS 63 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 20 64 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 21 65 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 21 66 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 21 67 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 22 68 30' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 22 69 3D' E AND 30' S FROM THE NW CORNER OF BLOCK A, PAD 22 1 FILL 2 NATURALSUBGRADE 3 LIME STABILIZED 4 CEMENT TREATED . A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D RETEST Respectfully Submitted. ~~ Tom Ellis ALPHA TESTING. INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently Identical or similar specimens Geotechnical Engineering & Construction Materials Testing & Environmental Engineering & Consulting