Loading...
Gateway BP(3.1)-LR071026 Rone Engineering Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 299965 Project No.: 0712786 Date of Service: 09/26/2007 Report Date: 10/26/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Constructors & Associates Concrete Supplier: Redi Mix Plant: 88 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 330J1501 Placement Date: 09/26/2007 Weather Conditions: Cloudy Time Sampled: 04:00am Temperature - Air: 780F Truck No: 1048 Air Content: 1.4% Overall Placement Location: Slab on deck on building 2, grid lines A-E/6-12 Measured Slump (inches) 5.5 Batch time: 03: 11 am Concrete: 760F Ticket No: 88054484 Unit Weight (pet): NA Sample Location: Grid line D/11.3 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 1 1 09/29/2007 3 6.00 28.27 69,510 2,460 Cone/Split 1 2 10/03/2007 7 6.00 28.27 90,470 3,200 Cone/Split 1 3 10/24/2007 28 6.00 28.27 100,570 3,560 Shear 1 4 10/24/2007 23 6.00 28.27 103,290 3,650 Cone/Split Average 3,610 Remarks: Water added at site: 5 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 1 of 4 Rone Engineering Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 299965 Project No.: 0712786 Date of Service: 09/26/2007 Report Date: 10/26/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Constructors & Associates Concrete Supplier: Redi Mix Plant: 88 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 330J1501 Placement Date: 09/26/2007 Weather Conditions: Cloudy Time Sampled: 05:15am Temperature - Air: 760F Truck No: 1089 Air Content: 1.3% Overall Placement Location: Slab on deck on building 2, grid lines A-E/6-12 Measured Slump (inches) 6.0 Batch time: 04:36am Concrete: 750F Ticket No: 88054490 Unit Weight (pcf): NA Sample Location: Grid line B/7 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 2 1 09/29/2007 3 6.00 28.27 78,090 2,760 Cone/Shear 2 2 10/03/2007 7 6.00 28.27 92,780 3,280 Shear 2 3 10/24/2007 28 6.00 28.27 117,930 4,170 Cone/Split 2 4 10/24/2007 28 6.00 28.27 118,300 4,180 Cone/Split Average 4,180 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KWIKW) Page 2 of 4 Rone Engineering Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 299965 Project No.: 0712786 Date of Service: 09/26/2007 Report Date: 10/26/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: . Constructors & Associates Concrete Supplier: Redi Mix Plant: 88 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 330J1501 Placement Date: 09/26/2007 Weather Conditions: Cloudy, sunny Time Sampled: 07:45am Batch time: 06:59am Temperature - Air: 780F Concrete: 770F Truck No: 1056 Ticket No: 88054504 Air Content: 1.2% Unit Weight (pet): NA Overall Placement Location: Slab on deck on building 2, grid lines A-E/6-12 Measured Slump (inches) 4.0 Sample Location: Grid line B/10 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 3 1 09/29/2007 3 6.00 28.27 97,370 3,440 Cone/Split 3 2 1 0/03/2007 7 6.00 28.27 111 ,130 3,930 Cone/Split 3 3 10/24/2007 28 6.00 28.27 142,810 5,050 Cone/Split 3 4 10/24/2007 28 6.00 28.27 136,670 4,830 Cone/Split Average 4,940 Remarks: Discrepancies noted on reinforcing steel inspection report #299907 were corrected prior to concrete placement. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 3 of 4