Gateway BP(3.1)-LR071012 Rone Engineering .. 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of In-Place Density Testing Report No.: 300571 Project No.: 0712786 Date of Service: 10/01/2007 Report Date: 10/12/2007 Project: PROJECT DATA Contractor: C s & Associates Test Method: ASTM D-6938 Gauge: Troxler 3430 Gauge Serial No: 33305 Test Mode: DT Standard Counts Moisture Density Current: 556 Current: 2572 Previous: 547 Previous: 2572 MOISTURE DENSITY RELATIONS ., Moisture % Maximum Density (pet) 89.0 Project Requirements Moisture Density Optimum +4 95 min MID No. 277809 Dark Brown I Clay Test Moisture Wet Density Dry Density Density No Test Location % (pet) (pet) (%max) - Paving - North fire lane 55' north, 50' west from northeast corner of 6" 277809 29.0 112.1 86.9 98 building 1, final Paving - North fire lane 2 20' north, 120' west from northeast corner of 6" 277809 27.6 112.9 88.5 99 building 1, final Paving - North fire lane 3 65' north, 200' west from northeast corner of 6" 277809 28.4 110.8 86.3 97 building 1, final Paving - North fire lane 4 125' west, 185' west from northeast comer of 6" 277809 29.1 110.9 85.9 97 building 1, final 1 0 \~ \ 111 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CHILB) Page 1 of 2 Rone Engineering .. 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of In-Place Density Testing Report No.: 300725 Project No.: 0712786 Date of Service: 10/02/2007 Report Date: 10/12/2007 Project: Gateway Business Center Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Constructors & Associates Test Method: ASTM D-6938 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 734 Current: 2507 Previous: 742 Previous: 2559 MOISTURE DENSITY RELATIONS MID No. 277809 Description Moisture % Maximum Density (pef) 89.0 Project Requirements Moisture Density Minimum +4 92-96 Dark Brown I Clay 27.0 Test No Test Location FIELD DENSITY TESTS Probe MID Depth No. Moisture Wet Density Dry Density Density % (pef) (pef) (% max) Fill Elevator pit, building 1, final Fill Elevator pit, building 2, final 6" 277809 32.2 111.8 84.6 95 2 6" 277809 31.9 110.9 84.1 95 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/LB) Page 1 of 2 Rone Engineering .. Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 300682 Project No.: 0712786 Date of Service: 10/02/2007 Report Date: 10/12/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi Mix Plant: 88 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 1524 Placement Date: 10/02/2007 Weather Conditions: Clear, calm Time Sampled: 03:50am Batch time: 03:14am Temperature - Air: 720F Concrete: 830F Truck No: 1090 Ticket No: 88054777 Air Content: 3.8% Unit Weight (pcf): NA Overall Placement Location: Paving grading plan north - 535.16' 43 E 104.04 Pg C2, 02 Measured Slump (inches) 5.0 Sample Location: Station 526.10 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 10/05/2007 3 6.00 28.27 67,850 2,400 Unbonded Cap 1 2 10/09/2007 7 6.00 28.27 85,760 3,030 Cone/Split 1 3 10/30/2007 28 1 4 10/30/2007 28 1 5 11/27/2007 56 L1MrrA TIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/LB) Page 1 of 5 Rone Engineering " Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 300682 Project No.: 0712786 Date of Service: 10/02/2007 Report Date: 10/12/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi Mix Plant: 88 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 1524 Placement Date: 10/02/2007 Weather Conditions: Clear, calm Time Sampled: 05: 15am Batch time: 04:27am Temperature - Air: 710F Concrete: 820F Truck No: 1089 Ticket No: 88054787 Air Content: 3.6% Unit Weight (pet): NA Overall Placement Location: Paving grading plan north - 535.16' 43 E 104.04 Pg C2, 02 Measured Slump (inches) 6.0 Sample Location: Stations 526.40 and 527.70 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 2 1 10/05/2007 3 6.00 28.27 65,990 2,330 Unbonded Cap 2 2 10/09/2007 7 6.00 28.27 83,660 2,960 Cone/Split 2 3 10/30/2007 28 2 4 10/30/2007 28 2 5 11/27/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, ltd. (CHILB) Page 2 of 5 Rone Engineering .. Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 300682 Project No.: 0712786 Date of Service: 10/02/2007 Report Date: 10/12/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi Mix Plant: 88 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 1524 Placement Date: 10/02/2007 Weather Conditions: Clear, calm Time Sampled: 06:00am Batch time: 05:32am Temperature - Air: 700F Concrete: 820F Truck No: 1058 Ticket No: 88054795 Air Content: 3.8% Unit Weight (pet): NA Overall Placement Location: Paving grading plan north - 535.16' 43 E 104.04 Pg C2, 02 Measured Slump (inches) 6.5 Sample Location: Station 525.90 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 3 1 10/05/2007 3 6.00 28.27 60,890 2,150 Unbonded Cap 3 2 10/09/2007 7 6.00 28.27 80,090 2,830 Shear 3 3 10/30/2007 28 3 4 10/30/2007 28 3 5 11/27/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/LB) Page 3 of 5 Rone Engineering ., Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 300682 Project No.: 0712786 Date of Service: 10/02/2007 Report Date: 10/12/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi Mix Plant: 88 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 1524 Placement Date: 10/02/2007 Weather Conditions: Cloudy, calm Time Sampled: 09:03am Batch time: 07:58am Temperature - Air: 730F Concrete: 880F Truck No: 1089 Ticket No: 88054810 Air Content: 3.6% Unit Weight (pet): NA Overall Placement Location: Paving grading plan north - 535.16' 43 E 104.04 Pg C2, 02 Measured Slump (inches) 6.0 Sample Location: Station 526.40 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 4 1 10/05/2007 3 6.00 28.27 63,310 2,240 Unbonded Cap 4 2 10/09/2007 7 6.00 28.27 77,180 2,730 Shear 4 3 10/30/2007 28 4 4 10/30/2007 28 4 5 11/27/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CHILB) Page 4 of 5