Loading...
Gateway BP(3.1)-LR071002 Rone Engineering .. 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of Reinforcing Steel Inspection Report No.: 299907 Project No.: 0712786 Date of Service: 09/25/2007 Report Date: 10/02/2007 Project: Gateway Business Center Coppell, Texas Services: Reinforcing Steel Inspection Report .of Inspection Locations and Items Inspected: Building 2, 2nd deck, slab on deck, wire mesh, grid lines A-E/6-12 Items Inspected: Conforming Non Items Inspected: Conforming Non Items Inspected: Co nfo rm ing Non Conforming Co nfo rm ing Conforming P lacing Drawings Bar Length Column Ties Properly Appro ved x and Shape x Tied and Spaced NA Bar Size x Pro per 8 ar Placement x Stirrup Spacing NA Bar Grade x Properly Tied x Stinrup Type NA Bars Clean x Dowel Bars in Place x Lapped Splices x Form Clean x ProperBarSupports x Corner 8 ars x NumberofBars x ProperCover x Mechanical Splices NA Discrepancies / Comments: 1. Bars (mesh) atedge of last concrete pour(s), grid lines A-E/6-12 had concrete caked on steel. 2. Forms had trash throughout area. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject maller provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/LB) Page 1 of 2 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of In-Place Density Testing Report No.: 300208 Project No.: 0712786 Date of Service: 09/27/2007 Report Date: 10/02/2007 Project: Gateway Business Center Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Constructors & Associates Test Method: ASTM D-6938 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 729 Current: 2520 Previous: 742 Previous: 2501 MOISTURE DENSITY RELATIONS MID No. 277809 Description Moisture % Maximum Density (pet) 89.0 Project Requirements Moisture Density Optimum +4 95 min Dark Brown I Clay 27.0 FIELD DENSITY TESTS Test No 2 Probe MID Moisture Wet Density Dry Density Density Test Location Depth No. % (pet) (pet) (%max) Paving subgrade Area F parking, west end, final 6" 277809 29.8 112.0 86.3 97 Paving subgrade Area F parking, center, final 6" 277809 29.1 111.8 86.6 97 Paving subgrade Area F parking, east end, final 6" 277809 29.1 111.5 86.4 97 3 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/LB) Page 1 of 2