Gateway BP(3.1)-LR071001 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Report of Concrete Compressive Strength Test Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report No.: 299347 Project No.: 0712786 Date of Service: 09/20/2007 Report Date: 10/01/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 88 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 1501 Placement Date: 09/20/2007 Weather Conditions: Clear, calm Time Sampled: 04:45am Batch time: 04:12am Temperature - Air: 720F Concrete: 870F Truck No: 1089 Ticket No: 88054234 Air Content: 0.8% Unit Weight (pcf): NA Overall Placement Location: Building 2, 2nd floor, slab on deck, grid lines A-D.9 Measured Slump (inches) 5.0 Sample Location: 20' from northeast side of building 2 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 1 1 09/24/2007 4 6.00 28.27 81,520 2,880 Shear 2 09/27/2007 7 6.00 28.27 86,980 3,080 Cone/Split 1 3 10/18/2007 28 6.00 28.27 114,310 ~ Cone/Split 1 4 10/18/2007 28 6.00 28.27 108,590 3,840 Cone/Split Average 5 11/15/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (compDsition, appearance, etc.) Dr any other feature Df similar subject matter prDvided by persons Dr conditions Dver which we have nD cDntroL Our letters and reports are for the exclusive use Df the clients to whDm they are addressed and shall nDt be reproduced except in full without the written approval of RDne Engineering Services, Ltd. (LB) Page 1 of 3 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 299347 Project No.: 0712786 Date of Service: 09/20/2007 Report Date: 10/01/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 88 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 1501 Placement Date: 09/20/2007 Weather Conditions: Clear, calm Time Sampled: 06:35am Batch time: 05:20am Temperature - Air: 700F Concrete: 890F Truck No: 1090 Ticket No: 88054239 Air Content: 0.9% Unit Weight (pcf): NA Overall Placement Location: Building 2, 2nd floor, slab on deck, grid lines A-D.9 Measured Slump (inches) 5.5 Sample Location: 20' from northeast side of building 2 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 2 1 09/24/2007 4 6.00 28.27 85,900 3,040 Cone/Split 2 2 09/27/2007 7 6.00 28.27 85,360 3,020 Shear 2 3 10/18/2007 28 6.00 28.27 106,930 3,780 Cone/Split 2 4 10/18/2007 28 6.00 28.27 114,740 4,060 Cone/Split Average 3,920 2 5 11/15/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exciusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB) Page 2 of 3 Rone Engineering . Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 299347 Project No.: 0712786 Date of Service: 09/20/2007 Report Date: 10/01/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 88 Specification Requirements Strength: 3,000 psi @28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 1501 Placement Date: 09/20/2007 Weather Conditions: Clear, calm Time Sampled: 04:45am Batch time: 04:12am Temperature - Air: 720F Concrete: 870F Truck No: 1089 Ticket No: 88054234 Air Content: 0.8% Unit Weight (pet): NA Overall Placement Location: Building 2, 2nd floor, slab on deck, grid lines A-D.9 Measured Slump (inches) 5.0 Sample Location: 20' from northeast side of building 2 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 1 1 09/24/2007 4 6.00 28.27 81,520 2,880 Shear 1 2 09/27/2007 7 6.00 28.27 86,980 3,080 Cone/Split 1 3 10/18/2007 28 6.00 28.27 114,310 4,040 Cone/Split 1 4 10/18/2007 28 6.00 28.27 108,590 3,840 Cone/Split Average 3,940 1 5 11/15/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB/JC) Page 1 of 3 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 299347 Project No.: 0712786 Date of Service: 09/20/2007 Report Date: 10/01/2007 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: 88 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 1501 Placement Date: 09/20/2007 Weather Conditions: Clear, calm Time Sampled: 06:35am Batch time: 05:20am Temperature - Air: 700F Concrete: 890F Truck No: 1090 Ticket No: 88054239 Air Content: 0.9% Unit Weight (pet): NA Overall Placement Location: Building 2, 2nd floor, slab on deck, grid lines A-D.9 Measured Slump (inches) 5.5 Sample Location: 20' from northeast side of building 2 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 2 1 09/24/2007 4 6.00 28.27 85,900 3,040 Cone/Split 2 2 09/27/2007 7 6.00 28.27 85,360 3,020 Shear 2 3 10/18/2007 28 6.00 28.27 106,930 3,780 Cone/Split 2 4 10/18/2007 28 6.00 28.27 114,740 4,060 Cone/Split Average 3,920 2 5 11/15/2007 56 LIMIT A TJONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB/JC) Page 2 of 3