Northlake College-LR071031 K L E I N F E L D E R 2211 Century Center Blvd., Suite 101, Irving, Texas 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 UNDERREAM DRILLED SHAFT REPORT TO: Dallas County Community College Dist. PROJECT: North Lake College, N Campus 1505 South Lamar, Suite 1015 W Sandy Lake Road @ SH 121 Dallas, Texas 75215 PROJECT NO: 87015 Test Date: 10/26/2007 Date: 10/31/2007 Technician: J. Mayo Report No: 107081 IDENTIFICATION S-2 U-0.9 R-0.5 P-0.5 R.1-20 MARK SHAFT DIAMETER 24" 24" 24" 24" 18" PLAN/ACTUAL 24" 24" 24" 24" 18" GROUND SURFACE ELEVATION TOP OF SHAFT ELEVATION 98.72' 98.78' 98.59' 98.55' 98.61' DEPTH TO BEARING STRATUM 8.58' 8.75' 9.08' 7.67' 8.50' UNDER REAM DIAMETER 72/72 72 1 72 72/72 72/72 54/54 PLAN/ACTUAL FINAL DEPTH OF SHAFT 14.25' 14.42' 14.25' 14.08' 14.17' DESCRIPTION OF BEARING STRATUM Tan Clay Tan Clay Tan Clay Tan Clay Tan Clay STEEL CASING N/A N/A N/A N/A N/A DIAMETER (IN.) / DEPTH (FT.) PLUMBNESS VARIATION Within Within Within Within Within Tolerance Tolerance Tolerance Tolerance Tolerance TIME DRILLING STARTED 8:58 AM 9:12 AM 9:31 AM 9:38 AM 11:27 AM TIME DRILLING COMPLETED 9:56 AM 10:34 AM 11:01 AM 11: 18 AM 12:04 PM REINFORCING STEEL 12.58' 12.17' 13.42' 13.08' 12.75' CAGE LENGTH HORIZONTAL REBAR #4 at #4 at #4 at #4 at #4 at QUANTITY / SIZE 12" 12" 12" 12" 12" VERTICAL REBAR 6 6 6 6 6 QUANTITY / SIZE #7 #7 #7 #7 #6 CONDITION OF SHAFT BOTTOM Clean Clean Clean Clean Clean BEFORE CONCRETE PLACEMENT Drv Dry Dry Drv Drv PLACEMENT OF CONCRETE STARTED 12:19 PM 12:25 PM 12:40 PM 1 :38 PM 1 :48 PM PLACEMENT OF CONCRETE COMPLETED 12:24 PM 12:31 PM 12:47 PM 1:46 PM 1:54 PM Remarks: 1 _ Top of shaft elevation obtained from construction drawings 1 contractor R.1-2.0 was the pier iliat was backfilled due to hitting sand on I UI I LI\Jr. Reports to: Starling Richardson Const.; AUn: Eric Stanaland (eps@starlingrichardson.com) Starling Richardson Const.; AUn: Andy Munoz (amunoz@starlingrichardson.com) a. KLEINFELDER DCCCD Bond Office; Alln: Brenda Spinelli (brenda.spinelli@dcccd.edu) \ ~ DCCCD Bond Office; Alln: James Williams (james.williams@dcccd.edu) DCCCD Bond Office; Alln: Mike Daniels (mike.daniels@dcccd.edu) Jacobs; Alln: Andrea Stogner (Andrea.stogner@jacobs.com) fI Joel Peters, P.E. Jacobs; Alln: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; Alln: Larry Davis 1- City of Coppell; AUn: Lee Stone The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected. They are not intended to be indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety. K L E I N F E L D E R 2211 Century Center Blvd., Suite 101, Irving, TX 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 IN-PLACE MOISTURE DENSITY TEST RESUL TS To: Dallas County Community College Dist. Test Date: 10/30/2007 1505 South Lamar, Suite 1015 Project No: 87015 Dallas, Texas 75215 Report Date: 10/31/2007 Report No: 107495 Project: North Lake Colleae, N Campus Definitions of Terms Location: W Sandy Lake Road @ SH 121 ROP- Rt Otr Point CL - Centerline Field Rep: J. Schuler LOP - Lt Otr Point Sta - Station Test Test Location Depth 0 Wet Field Dry Proctor Percent No. Lift D Density Moisture Density No. Proctor (%) (pcf) Density San Sewer Backfill 1 Wend -1' 122.6 22.8 99.8 001388 96.9 2 E end -1' 122.3 23.3 99.2 001388 96.3 Proctor No: Description Opt. Moisture Max. Density 001388 Grav and brown 18.5 103.0 Specs. Gauge No: 29880 Test Methods: ASTM D 2922 Dens. (%) 93 to 98 Std. Density Count 2527 ASTM D 3017 Moist. (%) 2 to 7 Std. Moist Count: 618 ASTM D 698 Trans. Depth (in.): 6 Remarks: Reports to: Starling Richardson Const.; Alln: Eric Stanaland (eps@starlingrichardson.com) Starling Richardson Const.; Alln: Andy Munoz (amunoz@starlingrichardson.com) DCCCD Bond Office; Alln: Brenda Spinelli (brenda.spinelli@dcccd.edu) w12EI~ DCCCD Bond Office; Alln: James Williams Oames.williams@dcccd.edu) DCCCD Bond Office; Alln: Mike Daniels (mike.daniels@dcccd.edu) Jacobs; Alln: Andrea Stogner (Andrea.stogner@jacobs.com) (I Joel Peters, P.E. Jacobs; Alln: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; Alln: Larry Davis 1- City of Coppell; Alln: Lee Stone The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected. They are not intended to be indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety. K L E I N F E L D E R 2211 Century Center Blvd., Suite 101, Irving, Texas 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 4x8 CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT TO: Dallas County Community College Dist. PROJECT: North Lake College, N Campus 1505 South Lamar, Suite 1015 W Sandy Lake Road @ SH 121 Dallas, Texas 75215 PROJECT NO: 87015 REPORT DATE: 10/31/2007 TECHNICIAN: J. Mayo REPORT NO: 107027 I CONCRETE FOR: Piers B-6, B.3-3.6, C.7-3.6, C-5 ! CYLINDER AGE DATE DATE AVG. CYLINDER CYLINDER FRACTURE TOTAL COMPRESSIVE MARK DAYS CAST TESTED DIAMETER, IN. AREA, IN.2 TYPE LOAD, LBS STRENGTH, PSI 107027A 7 10/2/07 1 0/9/07 4.01 12.63 5 41,810 3,310 107027B 28 10/2/07 10/30/07 4.01 12.63 3 55,930 4,430 107027C 28 10/2/07 10/30/07 4.01 12.63 2 52,280 4,140 1070270 HOLD 10/2/07 HOLD SUPPLIER: Southern Star AVERAGE 28 DAY STRENGTH: 4,285 MIX DESIGN: 000000007781 28 DAY STRENGTH REQUIREMENT: 3,000 ADDITIONAL INFORMATION IF MADE BY KLEINFELDER: ACTUAL SPECIFIED TRUCK NO. : 97 SLUMP: 6.5 TICKET NO. : 1102871 AIR TEMP. : 95 ACCUMULATED YDS: 20 of 20 MIX TEMP. : 97 TIME CAST: 3:49 PM AIR CONTENT: N/A TIME IN TRUCK: 35 min WATER ADDED (gal) : 0 WEATHER: Clear UNIT WEIGHT: N/A : FRACTURE TYPES: 1 Reasonably well-formed cones on both ends, less than 1 in. (25 mm) of cracking through caps. 2 Well-formed cone on one end, vertical cracks running through caps, no well-defined cone on other end. 3 Columnar vertical cracking through both ends, no well-formed cones. 4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type 1. 5 Side fractures at top or bottom (occur commonly with unbonded caps). 6 "imil'" tn Tvn.,,, hilt "nd of cvlinder is nnint.,rl. NOTES: . Compressive strengths determined in accordance with ASTM C39. . Cross-sectional area, diameter and length are standard unless otherwise noted. . Portions of the information contained in this report have been furnished by others. . Cylinders cured in laboratory in accordance with ASTM C31 unless otherwise noted. . Unbonded caps utilized in accordance with ASTM C1231 unless otherwise noted. Because of the violent release of energy stored in pads, the broken cylinder rarely exhibits conical fracture typical of capped cylinders and the sketches of types of fracture in Test Method C39 are not descriptive. . Samples taken in accordance with ASTM C172 where practicable. . When applicable, the following test procedures were used: Slump ASTM C143; Unit Weight ASTM C138; Air Content ASTM C173/ C231; Temperature ASTM C1064 Reports to: Starling Richardson Const.; Atln: Eric Stanaland (eps@starlingrichardson.com) Oo;/~ Starling Richardson Const.; Attn: Andy Munoz (amunoz@starlingrichardson.com) DCCCD Bond Office; Atln: Brenda Spinelli (brenda.spinelli@dcccd.edu) DCCCD Bond Office; Atln: James Williams Uames.williams@dcccd.edu) DCCCD Bond Office; Atln: Mike Daniels (mike.daniels@dcccd.edu) ~ Jacobs; Atln: Andrea Stogner (Andrea.stogner@jacobs.com) Joel Peters, P.E. Jacobs; Attn: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; Atln: Larry Davis 1- City of Coppell; Atln: Lee Stone The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected. They are not intended to be indicative of the qualities of apparently identical products. The use of our name must receive prior written approvaL Reports must be reproduced in their entirety.