Report of Concrete Compressive Strength Test
Report No.: 301133
Project No.: 0712932
Date of Service: 10/05/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 9349 PW
Placement Date: 10/05/2007
Weather Conditions: Clear
Time Sampled: 06:00am
Temperature - Air: 770F
Truck No: 133
Air Content: NA
Overall Placement Location:
Building slab, grid lines E-G/24-30
Batch time: 05:34am
Concrete: 850F
Ticket No: 14398
Unit Weight (pet): NA
Measured
Slump
(inches)
5.0
Sample Location:
Grid lines E.2/24.5
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
1 1 10/12/2007 7 6.00 28.27 122,070 4,320 Cone/Split
1 2 11/02/2007 28 6.00 28.27 155,820 5,510 Cone/Split
1 3 11/02/2007 28 6.00 28.27 155.490 5,500 Cone/Split
Average 5,510
1 4 11/30/2007 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/ED) Page 1 of 6
Rone En~==
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301133
Project No.: 0712932
Date of Service: 10/05/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Req uirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9349 PW
Placement Date: 10/05/2007
Weather Conditions: Clear
Time Sampled: 06:40am
Temperature - Air: 770F
Truck No: 133
Air Content: NA
Overall Placement Location:
Building slab, grid lines E-G/24-30
Batch time: 06:28am
Concrete: 840F
Ticket No: 14408
Unit Weight (pet): NA
Measured
Slump
(inches)
4.25
Sample Location:
Grid lines E.4/25.7
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (inZ) (Ibs) (psi) Type
2 1 10/12/2007 7 6.00 28.27 1 09,130 3,860 Cone/Split
2 2 11/02/2007 28 6.00 28.27 143,230 5,070 Cone/Shear
2 3 11/02/2007 28 6.00 28.27 147, 130 5,200 . Cone/Shear
Average 5,130
2 4 11/30/2007 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/ED) Page 2 of 6
Rone En~==
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301133
Project No.: 0712932
Date of Service: 10/05/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perfonm required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Req uirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9349 PW
Placement Date: 10/05/2007
Weather Conditions: Clear
Time Sampled: 07:30am
Temperature - Air: 800F
Truck No: 133
Air Content: NA
Overall Placement Location:
Building slab, grid lines E-G/24-30
Batch time: 07:22am
Concrete: 840F
Ticket No: 14418
Unit Weight (pet): NA
Measured
Slump
(inches)
5.0
Sample Location:
Grid lines E.8/27
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
3 1 10/12/2007 7 6.00 28.27 103,910 3,680 Cone/Split
3 2 11/02/2007 28 6.00 28.27 136,900 4,840 Cone/Split
3 3 11/02/2007 28 6.00 28.27 130,480 4,610 Cone/Split
Average 4,730
3 4 11/30/2007 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/ED) Page 3 of 6
Rone Engineering
.
Client: Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301133
Project No.: 0712932
Date of Service: 10/05/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9349 PW
Placement Date: 10/05/2007
Weather Conditions: Clear
Time Sampled: 09:05am
Temperature - Air: 810F
Truck No: 106
Air Content: NA
Overall Placement Location:
Building slab, grid lines E-G/24-30
Batch time: 08:53am
Concrete: 870F
Ticket No: 14430
Unit Weight (pet): NA
Measured
Slump
(inches)
3.75
Sample Location:
Grid lines E.2128
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
4 1 10/12/2007 7 6.00 28.27 114,320 4,040 Cone/Split
4 2 11/02/2007 28 6.00 28.27 155,240 5,490 Cone/Split
4 3 11/02/2007 28 6.00 28.27 152,300 5,390 Cone/Split
Average 5,440
4 4 11/30/2007 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar SUbject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMIED) Page 4 of 6
Rone En~~
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301133
Project No.: 0712932
Date of Service: 10/05/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9349 PW
Placement Date: 10/05/2007
Weather Conditions: Clear
Time Sampled: 10:22am
Temperature - Air: 830F
Truck No: 143
Air Content: NA
Overall Placement Location:
Building slab, grid lines E-G/24-30
Batch time:
Concrete: 870F
Ticket No: 14443
Unit Weight (pet): NA
Measured
Slump
(inches)
3.25
Sample Location:
Grid lines E.9/29
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
5 1 10/12/2007 7 6.00 28.27 117,790 4,170 Cone/Split
5 2 11/02/2007 28 6.00 28.27 159,010 5,620 Cone/Split
5 3 11/02/2007 28 6.00 28.27 152,350 5,390 Cone/Split
Average 5,510
5 4 11/30/2007 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMIED) Page 5 of 6
Rone En2~
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301133
Project No.: 0712932
Date of Service: 10/05/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9349 PW
Placement Date: 10/05/2007
Weather Conditions: Clear
Time Sampled: 11 :30am
Temperature - Air: 840F
Truck No: 143
Air Content: NA
Overall Placement Location:
Building slab, grid lines E-G/24-30
Batch time:
Concrete: 900F
Ticket No: 14452
Unit Weight (pet): NA
Measured
Slump
(inches)
4.0
Sample Location:
Grid lines E.2/29.5
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
6 1 10/12/2007 7 6.00 28.27 117,890 4,170 Cone/Split
6 2 11/02/2007 28 6.00 28.27 147,450 5,210 Cone/Split
6 3 11/02/2007 28 6.00 28.27 148,000 5,230 Shear
Average 5,220
6 4 11/30/2007 56
Started: 04:30am Finished: 12:30pm
Technician: Brad Hickman
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne
(1-ec copy)
1-cc Potter Concrete Attn: Mr. Ryan Skelly
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
Rone Engineering
V~
~
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMIED) Page 6 of 6
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301112
Project No.: 0712932
Date of Service: 10/05/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 3,000 psi @ 28 days
Slump (in.): NA
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Batch time: 09:46am
Concrete: 850F
Ticket No: 14429
Unit Weight (pcf): NA
Measured
Slump
(inches)
6.5
Mix Design 1.0.: 7751 PW
Placement Date: 10/05/2007
Weather Conditions: Clear
Time Sampled: 10:25am
Temperature - Air: 830F
Truck No: 101
Air Content: NA
Overall Placement Location:
Building piers C.B, C.2, B.2/1 A.B, A.5/0.9 U2.7, 2.2, 5.2, 1.6, 16.B, 1.2, 1
K.S, K.2, J,B, J.S/1
K.B,
Sample Location:
Pier C.B/1
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 10/12/2007 7 6.00 28.27 90,700 3,210 Cone/Split
1 2 10/12/2007 7 6.00 28.27 96,050 3,400 Cone/Split
Average 3,300
1 3 11/02/2007 28 6.00 28.27 135,350 4,790 Cone/Shear
1 4 11/02/2007 28 6.00 28.27 128,900 4,560 Cone/Split
Average 4,670
1 5 11/30/2007 56
Technician: Chris Harbour Rone Engineering
See Report 301111 for technician time~ ~
Report Distribution: . ~
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne . ... . .
(1-ec copy)
1-cc p~tter Concrete Attn: Mr. Ryan Skelly K. Scott Watson, AET
1-cc City of Coppell Attn: Mr. Lee Stone Pro'act Manager
1-cc City of Coppell Attn: Mr. Larry Davis J
~
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 1 of 1
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 300939
Project No.: 0712932
Date of Service: 10/04/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Req uirements
Strength: 3,000 psi @ 28 days
Slump (in.): NA
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 7751 PW
Placement Date: 10/04/2007
Weather Conditions: Clear
Time Sampled: 10:50am
Temperature - Air: 850F
Truck No: 120
Air Content: NA
Overall Placement Location:
Building piers G.211, U4.8, 4.2, 3.8, D.2, F.2, E.8, E.2, D.8, F.8/1
Measured
Slump
(inches)
7.25
Batch time: 09:42am
Concrete: 870F
Ticket No: 14377
Unit Weight (pet): NA
Sample Location:
Pier G.2/1
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
1 1 10/11/2007 7 6.00 28.27 93,980 3,320 Cone/Split
1 2 10/11/2007 7 6.00 28.27 92,230 3,260 Shear
Average 3,290
1 3 11/01/2007 28 6.00 28.27 125,420 4,440 Cone/Split
1 4 11/01/2007 28 6.00 28.27 126,170 4,460 Cone/Split
Average 4,450
1 5 11/29/2007 56
Technician: Chris Harbour Rone Engineering
See Report 300938 for technician timep ~
Report Distribution: ~ ~
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne . . . ~
(1-ec copy) -
1-cc Potter Concrete Attn: Mr. Ryan Skelly K S tt W t AET
1-cc City of Coppell Altn: Mr. Lee Stone . p ~ t ~ son,
1-cc City of Coppell Altn: Mr. Larry Davis roJec anager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CHIED) Page 1 of 1
Rone En9.ineering
.-
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303068
Project No.: 0712932
Date of Service: 10/26/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 1 on-site mix
Specification Requirements
Strength: 3,000 psi @ 28 days
Slump (in.): 5" - 7"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
6.0
Mix Design 1.0.: 7751 PW
Placement Date: 10/26/2007
Weather Conditions: Clear, light wind
Time Sampled: 12:20pm Batch time: 11 :28am
Temperature - Air: 690F Concrete: 770F
Truck No: 107 Ticket No: 14934
Air Content: NA Unit Weight (pet): NA
Overall Placement Location:
Straight shaft piers at column lines B.4/30, A.9/30, A.5/30, U27.8, L.1/27.8, L.2/27.8,
L.3/27.8
Sample Location:
Pier at column lines U27.8
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (inZ) (Ibs) (psi) Type
1 1 11/02/2007 7 6.00 28.27 101,270 3,580 Cone/Split
1 2 11/23/2007 28
1 3 11/23/2007 28
1 4 12/21/2007 56
Technician: Tommy Carver Rone Engineering
See Report 303067 for technician time~ ~
Report Distribution: . . ~. .
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byme .' ..
(1-ec copy) -
1-cc Potter Concrete Attn: Mr. Ryan Skelly K Scott Watson AET
1-cc City of Coppell Attn: Mr. Lee Stone . p . ct M '
1-cc City of Coppell Attn: Mr. Larry Davis roJe anager
Remarks: Water added at site: 10 gallons
~
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/JB) Page 1 of 1
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303088
Project No.: 0712932
Date of Service: 10/26/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell , Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Redi Mix
Plant: 136
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Batch time: 03:36am
Concrete: 800F
Ticket No: 13600163
Unit Weight (pet): NA
Measured
Slump
(inches)
4.0
Mix Design 1.0.: L40N980A
Placement Date: 10/26/2007
Weather Conditions: Clear
Time Sampled: 04:20am
Temperature - Air: 500F
Truck No: 1182
Air Content: NA
Overall Placement Location:
Panels at Point West VII- 1st mix (380 yds) - panels 114,110,109,122,165,162,98,
4, 3, 1
Sample Location:
Panel 3
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 11/02/2007 7 6.00 28.27 151,860 5,370 Cone/Split
1 2 11/23/2007 28
1 3 11/23/2007 28
1 4 12/21/2007 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/JB) Page 1 of 4
Rone En~~
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303088
Project No.: 0712932
Date of Service: 10/26/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Redi Mix
Plant: 136
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Batch time: 05:03am
Concrete: 800F
Ticket No: 13600173
Unit Weight (pet): NA
Measured
Slump
(inches)
4.25
Mix Design 1.0.: L40N980A
Placement Date: 10/26/2007
Weather Conditions: Clear
Time Sampled: 05:30am
Temperature - Air: 500F
Truck No: 1031
Air Content: NA
Overall Placement Location:
Panels at Point West VII- 1st mix (380 yds) - panels 114, 110, 109, 122, 165, 162,98,
4,3,1
Sample Location:
Panel 1
REPORT OF TESTS
Cylinder
Marked Date
Set No. Tested
2 1 11/02/2007
2 2 11/23/2007
2 3 11/23/2007
2 4 12/21/2007
Age
(days)
7
Diameter
(in)
6.00
28
28
56
Concrete Compressive Cylinder 6" x 12"
Maximum
Load
(Ibs)
160,170
Compressive
Strength
(psi)
5,660
Fracture
Type
Shear
Area
(in')
28.27
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CHfJB) Page 2 of 4
Rone Eni==
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303088
Project No.: 0712932
Date of Service: 10/26/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Redi Mix
Plant: 136
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Batch time: 05:53am
Concrete: 820F
Ticket No: 13600182
Unit Weight (pet): NA
Measured
Slump
(inches)
5.0
Mix Design I.D.: L40N980A
Placement Date: 10/26/2007
Weather Conditions: Clear
Time Sampled: 06:30am
Temperature - Air: 520F
Truck No: 1189
Air Content: NA
Overall Placement Location:
Panels at Point West VII - 1 st mix (380 yds) - panels 114, 110, 109, 122, 165, 162, 98,
4,3, 1
Sample Location:
Panel 122
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
3 1 11/02/2007 7 6.00 28.27 102,360 3,620 Shear
3 2 11/23/2007 28
3 3 11/23/2007 28
3 4 12/21/2007 56
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/JB) Page 3 oU
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303088
Project No.: 0712932
Date of Service: 10/26/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Redi Mix
Plant: 136
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Batch time: 07:37am
Concrete: 840F
Ticket No: 13600196
Unit Weight (pet): NA
Measured
Slump
(inches)
5.25
Mix Design I.D.: L40N980A
Placement Date: 10/26/2007
Weather Conditions: Clear
Time Sampled: 08:00am
Temperature - Air: 550F
Truck No: 1190
Air Content: NA
Overall Placement Location:
Panels at Point West VII - 1st mix (380 yds) - panels 114,110,109, 122, 165, 162, 98,
4, 3, 1
Sample Location:
Panel 109
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (inZ) (Ibs) (psi) Type
4 1 11/02/2007 7 6.00 28.27 114,690 4,060 Cone/Split
4 2 11/23/2007 28
4 3 11/23/2007 28
4 4 12/21/2007 56
Started: 03:00am Finished: 03:45pm
Technician: Montreal Bailey
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne
(1-ec copy)
1-cc Potter Concrete Attn: Mr. Ryan Skelly
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
Rone Engineering
V~~
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/JB) Page 4 of 4
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303197
Project No.: 0712932
Date of Service: 10/26/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 1
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
4.0
Mix Design 1.0.: 9349PW
Placement Date: 10/26/2007
Weather Conditions: Sunny, clear
Time Sampled: 09:15am Batch time: 08:58am
Temperature - Air: 600F Concrete: 840F
Truck No: 131 Ticket No: 14916
Air Content: NA Unit Weight (pet): NA
Overall Placement Location:
Panels at Point West VII - 2nd mix (405 yds), panels 111-113, 153-160. 163-164,5-8
Sample Location:
Panel 113
REPORT OF TESTS
Cylinder
Marked Date
Set No. Tested
1 1 11/02/2007
1 2 11/23/2007
1 3 11/23/2007
1 4 12/21/2007
Age
(days)
7
Diameter
(in)
6.00
28
28
56
Remarks: Water added at site: 10 gallons
Concrete Compressive Cylinder 6" x 12"
Maximum
Load
(Ibs)
118,770
Compressive
Strength
(psi)
4,200
Fracture
Type
Cone/Shear
Area
(in')
28.27
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition. appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/JB) Page 1 of 4
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303197
Project No.: 0712932
Date of Service: 10/26/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 1
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
4.75
Mix Design I.D.: 9349PW
Placement Date: 10/26/2007
Weather Conditions: Sunny, clear
Time Sampled: 11 :35am Satch time: 11: 19am
Temperature - Air: 650F Concrete: 860F
Truck No: 120 Ticket No: 14933
Air Content: NA Unit Weight (pet): NA
Overall Placement Location:
Panels at Point West VII - 2nd mix (405 yds), panels 111-113, 153-160, 163-164, 5-8
Sample Location:
Panel 155
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
2 1 11/02/2007 7 6.00 28.27 111 , 130 3,930 Cone/Split
2 2 11/23/2007 28
2 3 11/23/2007 28
2 4 12/21/2007 56
Remarks: Water added at site: 5 gallons
L1MrrA TIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, ltd.
(CH/JB) Page 2 of 4
Rone En~==
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303197
Project No.: 0712932
Date of Service: 10/26/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 1
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
5.0
Mix Design 1.0.: 9349PW
Placement Date: 10/26/2007
Weather Conditions: Sunny, clear
Time Sampled: 01 :05pm Batch time: 12:48pm
Temperature - Air: 650F Concrete: 860F
Truck No: 131 Ticket No: 14946
Air Content: NA Unit Weight (pet): NA
Overall Placement Location:
Panels at Point West VII - 2nd mix (405 yds), panels 111-113, 153-160, 163-164, 5-8
Sample Location:
Panel 160
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
3 1 11/02/2007 7 6.00 28.27 112,320 3,970 Cone/Split
3 2 11/23/2007 28
3 3 11/23/2007 28
3 4 12/21/2007 56
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/JB) Page 3 of 4
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303197
Project No.: 0712932
Date of Service: 10/26/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 1
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
5.25
Mix Design 1.0.: 9349PW
Placement Date: 10/26/2007
Weather Conditions: Sunny, clear
Time Sampled: 01 :50pm Batch time: 01 :33pm
Temperature - Air: 700F Concrete: 860F
Truck No: 106 Ticket No: 14954
Air Content: NA Unit Weight (pet): NA
Overall Placement Location:
Panels at Point West VII - 2nd mix (405 yds), panels 111-113, 153-160, 163-164, 5-8
Sample Location:
Panel 5
REPORT OF TESTS
Technician: Montreal Bailey Rone Engineering
See Report 303088 for technician time~~
Report Distribution: .
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byme .' ....
(1-eccopy) -
1-cc p~tter Concrete Attn: Mr. Ryan Skelly K. Scott Watson AET
1-cc City of Coppell Attn: Mr. Lee Stone p . ct M '
1-cc City of Coppell Attn: Mr. Larry Davis roJe anager
Cylinder
Marked Date
Set No. Tested
4 1 11/02/2007
4 2 11/23/2007
4 3 11/23/2007
4 4 12/21/2007
Age
(days)
7
Diameter
(in)
6.00
28
28
56
Remarks: Water added at site: 10 gallons
Concrete Compressive Cylinder 6" x 12"
Maximum
Load
(Ibs)
113,070
Compressive
Strength
(psi)
4,000
Fracture
Type
Shear
Area
(in')
28.27
~
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearanoe, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduoed except in full without the written approval of Rone Engineering Servioes, Ltd.
(CH/JB) Page 4 of 4
Rone En9.ineering
.-
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich,Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 302970
Project No.: 0712932
Date of Service: 10/25/2007
Report Date: 11/05/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10 - on site mix
Specification Requirements
Strength: 3,000 psi @28 days
Slump (in.): 5" - 7"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
6.5
Mix Design I.D.: 7751
Placement Date: 10/25/2007
Weather Conditions: Clear, windy
Time Sampled: 01 :25pm Batch time: 01 :05pm
Temperature - Air: 640F Concrete: 580F
Truck No: 120 Ticket No: 8150
Air Content: NA Unit Weight (pcf): NA
Overall Placement Location:
Piers at column lines: E.2/30, 0.7/30, 0.2/30, C.7/30, C.2/30, U28.2, U28.7, U29.2,
U29.7, U30, L.6/30, L.B/30, (continue)
Sample Location:
Pier at column line 0.2/30
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 11/01/2007 7 6.00 28.27 101,630 3,590 Cone/Split
1 2 11/22/2007 28
1 3 11/22/2007 28
1 4 12/20/2007 56
Technician: Tommy Carver Rone Engineering
See Report 302969 for technician time~ ~
Report Distribution: ' ....dhf'
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne ~--. . . .
(1-ec copy) -
1-cc p~tter Concrete Attn: Mr. Ryan Skelly K. Scott Watson AET
1-cc CIty of Coppell Attn: Mr. Lee Stone p . ct M '
1-cc City of Coppell Attn: Mr. Larry Davis rOJe anager
Remarks: K.2/30, K.5/30, L.3/30, B.9/30
~
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/JB) Page 1 of 1