Loading...
Duke Lesley 3C-LR071108 Rone En~~ 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, 8te 600, Houston, TX 77040 4421 Freldrlch, 8te 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 301736 Project No.: 0711530 Date of Service: 10/10/2007 Report Date: 11/08/2007 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Project: Services: est compressive strength test specimens prepared by others and picked up at the jobsite. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: NA Plant: NA Specification Requirements Strength: 3,500 psi @ 28 days Slump (in.): NA Air (%): NA, Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064h.. ~ ASTM C-138 rf) ASTM C-39 Z ~ Mix Design 1.0.: NA Placement Date: 10/09/2007 Weather Conditions: NA Time Sampled: Temperature - Air: Truck No: NA Air Content: NA Overall Placement Location: Red stamp concrete in median Measu red Slump (inches) Batch time: Concrete: Ticket No: NA Unit Weight (pet): NA Sample Location: Same as above REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in") (Ibs) (psi) Type 1 1 10/16/2007 7 6.00 28.27 96,440 3,410 Shear 1 2 11/06/2007 28 6.00 28.27 125,590 4,440 Cone/Split 1 3 11/06/2007 28 6.00 28.27 125,820 4,450 Shear Average 4,450 1 4 12/04/2007 56 Remarks: All information other than concrete compressive assumed to be correct. Technician: Dane Campbell Rone Engineering See Report 301685 for technician timep ~ Report Distribution: . ~ Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne . . . . (1-ec copy) 1-cc P~tter Concrete Attn: Mr. Ryan Skelly K. Scott Watson, AET 1-cc City of Coppell Attn: Mr. Lee Stone Project Manager 1-cc City of Coppell Attn: Mr. Larry Davis ~ LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/ED) Page 1 of 1 ~~ Rone Eni~ Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freldrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 303627 Project No.: 0711530 Date of Service: 10/31/2007 Report Date: 11/08/2007 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 7752 PW Placement Date: 10/31/2007 Weather Conditions: Clear Time Sampled: 05:15am Temperature - Air: 610F Truck No: 109 Air Content: 4.0% Overall Placement Location: Paving - west of building 1 Measured Slump (inches) 4.5 Batch time: 04:43am Concrete: 660F Ticket No: 8613 Unit Weight (pet): NA Sample Location: 52' north, 30' west from south side of placement REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 90,960 Cylinder Marked Date Set No. Tested 1 1 11/07/2007 1 2 11/28/2007 1 3 11/28/2007 1 4 12/26/2007 Age (days) 7 Diameter (in) 6.00 28 28 56 Compressive Strength (psi) 3,220 Fracture Type Shear Area (in') 28.27 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/JB) Page 1 of7 Rone En~== Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 303627 Project No.: 0711530 Date of Service: 10/31/2007 Report Date: 11/08/2007 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plart: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 7752 PW Placement Date: 10/31/2007 Weather Conditions: Clear Time Sampled: 05:55am Temperature - Air: 580F Truck No: 109 Air Content: 4.0% Overall Placement Location: Paving - west of building 1 Batch time: 05:34am Concrete: 670F Ticket No: 8623 Unit Weight (pet): NA Measured Slump (inches) 4.5 Sample Location: 120' north, 22' west from southeast end of placement Area (in') 28.27 REPORT OF TESTS Compressive Strength (psi) 3,530 Fracture Type Shear Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 99,710 Cylinder Marked Date Set No. Tested 2 1 11/07/2007 2 2 11/28/2007 2 3 11/28/2007 2 4 12/26/2007 Age (days) 7 Diameter (in) 6.00 28 28 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CHIJB) Page 2 of 7 Rone En2~ Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214)630-9745 Report of Concrete Compressive Strength Test Report No.: 303627 Project No.: 0711530 Date of Service: 10/31/2007 Report Date: 11/08/2007 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (Ufo): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 7752 PW Placement Date: 10/31/2007 Weather Conditions: Clear Time Sampled: 07:15am Temperature - Air: 610F Truck No: 110 Air Content: 4.0% Overall Placement Location: Paving - west of building 1 Batch time: 06:47am Concrete: 700F Ticket No: 8633 Unit Weight (pet): NA Measured Slump (inches) 4.0 Sample Location: 200' north, 24' west from southeast comer of placement REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in") (Ibs) (psi) Type 3 1 11/07/2007 7 6.00 28.27 85,120 3,010 Shear 3 2 11/28/2007 28 3 3 11/28/2007 28 3 4 12/26/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/JB) Page 3 of 7 Rone En~== Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, 8te 600, Houston, TX 77040 4421 Freidrich, 8te 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 303627 Project No.: 0711530 Date of Service: 10/31/2007 Report Date: 11/08/2007 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 7752 PW Placement Date: 10/31/2007 Weather Conditions: Sunny Time Sampled: 08:45am Temperatu~ - Air: 620F Truck No: 109 Air Content: 4.0% Overall Placement Location: Paving - west of building 1 Batch time: 08:25am Concrete: 700F Ticket No: 8643 Unit Weight (pet): NA Measured Slump (inches) 4.75 Sample Location: 200' south, 24' west from northeast corner of placement REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 4 1 11/07/2007 7 6.00 28.27 94,450 3,340 Cone/Split 4 2 11/28/2007 28 4 3 11/28/2007 28 4 4 12/26/2007 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/JB) Page 4 of 7 Rone Eni== Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214)630-9745 Report of Concrete Compressive Strength Test Report No.: 303627 Project No.: 0711530 Date of Service: 10/31/2007 Report Date: 11/08/2007 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 7752 PW Placement Date: 10/31/2007 Weather Conditions: Sunny Time Sampled: 09:35am Temperature - Air: 630F Truck No: 138 Air Content: 4.0% Overall Placement Location: Paving - west of building 1 Batch time: 09:24am Concrete: 690F Ticket No: 8653 Unit Weight (pet): NA Measured Slump (inches) 5.0 Sample Location: 150' south, 20' west from northeast corner of placement Area (in') 28.27 REPORT OF TESTS Compressive Strength (psi) 3,380 Fracture Type Cone/Split Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 95,610 Cylinder Marked Date Set No. Tested 5 1 11/07/2007 5 2 11/28/2007 5 3 11/28/2007 5 4 12/26/2007 Age (days) 7 Diameter (in) 6.00 28 28 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/JB) Page 5 of 7 Rone En~== Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 303627 Project No.: 0711530 Date of Service: 10/31/2007 Report Date: 11/08/2007 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Req uirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 7752 PW Placement Date: 10/31/2007 Weather Conditions: Sunny Time Sampled: 11 :OOam Temperature - Air: 640F Truck No: 138 Air Content: 4.0% Overall Placement Location: Paving - west of building 1 Batch time: 10:50am Concrete: 690F Ticket No: 8663 Unit Weight (pet): NA Measured Slump (inches) 5.0 Sample Location: 90' south, 30' west from northeast comer of placement Area (in') 28.27 REPORT OF TESTS Compressive Strength (psi) 2,870 Fracture Type Shear Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 81,110 Cylinder Marked Date Set No. Tested 6 1 11/07/2007 6 2 11/28/2007 6 3 11/28/2007 6 4 12/26/2007 Age (days) 7 Diameter (in) 6.00 28 28 56 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/JB) Page 6 of 7 Rone Eni~ Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W L1We York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 303627 Project No.: 0711530 Date of Service: 10/31/2007 Report Date: 11/08/2007 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Req uirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 7752 PW Placement Date: 10/31/2007 Weather Conditions: Sunny Time Sampled: 12:05pm Temperature - Air: 700F Truck No: 138 Air Content: 5.0% Overall Placement Location: Paving - west of building 1 Measured Slump (inches) 5.0 Batch time: 11 :51 am Concrete: 730F Ticket No: 8673 Unit Weight (pet): NA Sample Location: 40' south, 40' west from northeast comer of placement REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 81,870 Cylinder Marked Date Set No. Tested 7 1 11/07/2007 7 2 11/28/2007 7 3 11/28/2007 7 4 12/26/2007 Age (days) 7 Diameter (in) 6.00 28 28 56 Compressive Strength (psi) 2,900 Fracture Type Shear Area (in") 28.27 Started: 03:30am Finished: 01 :45pm Technician: Brad Hickman Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne (1-ec copy) 1-cc Potter Concrete Attn: Mr. Ryan Skelly 1-cc City of Coppell Attn: Mr. Lee Stone 1-cc City of Coppell Attn: Mr. Larry Davis Rone Engineering V~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services. Ltd. (CH/JB) Page 7 of 7