Loading...
Alexander Ct-LR071108 ,~ . ALPHA TESTING, INC. 2209 Wisconsin st., Suite 700 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR: MIRA MAR DEVELOPMENT CORPO TION COLLEYVILLE, TEXAS DATE: 11/08/07 PROJECT: ALEXANDER COURT COPPELL, TEXAS OUR REPORT NO.: 070021-20 TEST DATA: TEST ~ SOIL 10 OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT DATE MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT- NO. DEPTH NUMBER % PCF % PCF COMPACTION I 116 11/08/07 FG-3.0 1 12.3 119.4 12.3 119 100 1-A 117 11/08/07 FG-2.0 1 12.3 119.4 13.0 117 98 1-A 118 11/08/07 FG-1.0 1 12.3 119.4 13.2 116 J 97 1-A 119 11/08/07 FG-3.0 1 12.3 119.4 13.2 116 97 1-A 120 11/08/07 FG-2.0 1 12.3 119.4 13.1 117 98 1-A 121 11/08/07 FG-1.0 1 12.3 119.4 12.6 119 100 1-A 122 11/08/07 FG-3.0 2 15.2 114 16.3 109 ~ 1-A TEST LOCATION: UTILITIES 116 SANITARY SEWER SERVICE TO BLOCK A, PAD 20 117 SANITARY SEWER SERVICE TO BLOCK A, PAD 20 1 FILL 2 NATURALSUBGRADE 3 LIME STABILIZED 4 CEMENT TREATED . A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICA B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST 118 SANITARY SEWER SERVICE TO BLOCK A, PAD 20 119 SANITARY SEWER SERVICE TO BLOCK A, PAD 22 120 SANITARY SEWER SERVICE TO BLOCK A, PAD 22 121 SANITARY SEWER SERVICE TO BLOCK A, PAD 22 122 SANITARY SEWER SERVICE TO BLOCK A, PAD 26 Respectfully Submitted, ~~ Tom Ellit- ALPHA TESTING, INC. OUf test results and reports are for the exclUSive use of the Client (and thelf designated reCIpients on file In our office) and shall not be reproduced and/or distributed except with express approval of ALPHA The use of our name and test results must receive our wntten approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently Identical or similar specimens Geotechnical Engineering & Construction Materials Testing & Environmental Engineering & Consulting I~A TESTING, INe. 2209 Wisconsin Sf.. Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR: MIRA MAR DEVELOPMENT CORPORATION COLLEYVILLE, TEXAS DATE: 11/08/07 PROJECT: ALEXANDER COURT COPPELL, TEXAS OUR REPORT NO.: 070021-20A TEST DATA: TEST ~ SOIL 10 OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT DATE MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT' NO. DEPTH NUMBER % PCF % PCF COMPACTION 123 11/08/07 FG-2.0 3 13.0 115.4 13.5 115 99 1-A 124 11/08/07 FG-1.0 3 13.0 115.4 13.2 115 100 1-A 125 11/08/07 FG-3.0 3 13.0 115.4 12.9 113 98 1-A 126 11/08/07 FG-2.0 3 13.0 115.4 14.5 113 98 1-A 127 11/08/07 FG-1.0 3 13.0 115.4 13.1 115 99 1-A TEST LOCATION: UTILITIES 123 SANITARY SEWER SERVICE TO BLOCK A, PAD 26 124 SANITARY SEWER SERVICE TO BLOCK A, PAD 26 125 SANITARY SEWER SERVICE TO BLOCK A, PAD 29 126 SANITARY SEWER SERVICE TO BLOCK A, PAD 29 127 SANITARY SEWER SERVICE TO BLOCK A, PAD 29 1 FILL 2 NATURALSUBGRADE 3 LIME STABILIZED 4. CEMENT TREATED . A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS o RETEST Respectfully Submitted. ~~ Tom Ellis ALPHA TESTING. INC Our test results and reports are for the exclusive use of the Client (and thelf deSignated recipIents on file In our office) and shall not be reproduced and/or distributed except with express approval of ALPHA The use of our name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens Geotechnical Engineering & Construction Materials Testing & Environmental Engineering & Consulting