Northlake College-LR071127 KlEINFElDER 2211 Century Center Blvd., Suite 101, Irving, Texas 75062 972-870-0808 Metro 972-953-0398 F 972-870-0802 4x8 CONCRETE CYLINDER COMP IVE STRENGTH REPORT TO: Dallas County Community College Dist 1505 South Lamar, Suite 1015 Dallas, Texas 75215 MfZROJECT: North Lake College, N Campus .A ,\ -z:., 'h W Sandy Lake Road @ SH 121 \-\..r F15R JECT NO: 87015 TECHNICIAN: J. Mayo CONCRETE FOR: Grade beam T-6.8 to VA ~il~ REPORT DATE: 11/27/2007 REPORT NO: 117093 Page 1 of 2 CYLINDER DATE DATE AVG. CYLINDER CYLINDER FRACTURE TOTAL COMPRESSIVE MARK CAST TESTED DIAMETER, IN. AREA,IN.2 TYPE LOAD, LBS STRENGTH, PSI 117093A 11/15/07 11/22/07 4.00 12.57 N/A 49,870 C? 117093B 11/15/07 12/13/07 117093C 28 11/15/07 12/13/07 1170930 HOLD 11/15/07 HOLD SUPPLIER: Southern Star MIX DESIGN: 000000009355 ADDITIONAL INFORMATION IF MADE BY KLEIN FELDER: AVERAGE 28 DAY STRENGTH: 28 DAY STRENGTH REQUIREMENT: 4,000 TRUCK NO. : TICKET NO. : ACCUMULATED YDS: TIME CAST: TIME IN TRUCK: WEATHER: 80 1140661 30 of 60 2:51 PM 26min Clear SLUMP: AIR TEMP. : MIX TEMP.: AIR CONTENT: WATER ADDED (gal) : UNIT WEIGHT: SPECIFIED FRACTURE TYPES: 1 Reasonably well-formed cones on both ends, less than 1 in. (25 mm) of cracking through caps. 2 Well-formed cone on one end. vertical cracks running through caps, no well-defined cone on other end. 3 Columnar vertical cracking through both ends. no well-formed cones. 4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type 1. 5 Side fractures at top or bottom (occur commonly with unbonded caps). 6 NOTES: . Compressive strengths determined in accordance with ASTM C39. . Cross-sectional area, diameter and length are standard unless otherwise noted. . Portions of the information contained in this report have been furnished by others. . Cylinders cured in laboratory in accordance with ASTM C31 unless otherwise noted. . Unbonded caps utilized in accordance with ASTM C1231 unless otherwise noted. Because of the violent release of energy stored in pads, the broken cylinder rarely exhibits conical fracture typical of capped cylinders and the sketches of types of fracture in Test Method C39 are not descriptive. . Samples taken in accordance with ASTM C172 where practicable. . When applicable, the following test procedures were used: Slump ASTM C143; Unit Weight ASTM C138; Air Content ASTM C173/ C231; Temperature ASTM C1064 Reports to: Starling Richardson Const.; Altn: Eric Stanaland (eps@starlingrichardson.com) Starling Richardson Const.; Altn: Andy Munoz (amunoz@starlingrichardson.com) DCCCD Bond Office; Alln: Brenda Spinelli (brenda.spinelli@dcccd.edu) DCCCD Bond Office; Alln: James Williams (james.williams@dcccd.edu) DCCCD Bond Office; Alln: Mike Daniels (mike.daniels@dcccd.edu) Jacobs; Alln: Andrea Stogner (Andrea.stogner@jacobs.com) Jacobs; Altn: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; Altn: Larry Davis 1- City of Coppell; Alln: Lee Stone Joel Peters, P.E. The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected. They are not intended to be indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety. K L E I N F E L D E R 2211 Century Center Blvd., Suite 101, Irving, Texas 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 4x8 CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT TO: Dallas County Community College Dist. PROJECT: North Lake College, N Campus 1505 South Lamar, Suite 1015 W Sandy Lake Road @ SH 121 Dallas, Texas 75215 PROJECT NO: 87015 REPORT DATE: 11/27/2007 TECHNICIAN: J. Mayo REPORT NO: 117093 Page 2 of 2 CONCRETE FOR: Pier caps R-4 to L.9-4, L.9-6 to R-6 CYLINDER AGE DATE DATE AVG. CYLINDER CYLINDER FRACTURE TOTAL COMPRESSIVE MARK D~ CAST TESTED DIAMETER, IN. AREA,IN.2 TYPE LOAD, LBS STRENqTH, PSI 117094A (;I 11/15/07 11/22/07 4.00 12.57 N/A 52,220 r!Y 117094B 11/15/07 12/13/07 117094C "'" 28 11/15/07 12/13/07 1170940 HOLD 11/15/07 HOLD SUPPLIER: Southern Star AVERAGE 28 DAY STRENGTH: MIX DESIGN: 000000009355 28 DAY STRENGTH REQUIREMENT: 4,000 ADDITIONAL INFORMATION IF MADE BY KLEINFELDER: - I ACTUAL SPECIFIED I TRUCK NO. : 26 SLUMP: 5.0 TICKET NO. : 1140724 AIR TEMP. : 70 ACCUMULATED YDS : 60 of 60 MIX TEMP. : 83 TIME CAST: 3:27 PM AIR CONTENT: N/A TIME IN TRUCK: 32 min WATER ADDED (gal): 0 WEATHER: Clear UNIT WEIGHT: N/A : FRACTURE TYPES: 1 Reasonably well-formed cones on both ends, less than 1 in. (25 mm) of cracking through caps. 2 Well-formed cone on one end, vertical cracks running through caps, no well-defined cone on other end. 3 Columnar vertical cracking through both ends, no well-formed cones. 4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type 1. 5 Side fractures at top or bottom (occur commonly with un bonded caps). 6 'linn..r i" nnint..n NOTES: . Compressive strengths determined in accordance with ASTM C39. . Cross-sectional area, diameter and length are standard unless otherwise noted. . Portions of the information contained in this report have been furnished by others. . Cylinders cured in laboratory in accordance with ASTM C31 unless otherwise noted. . Unbonded caps utilized in accordance with ASTM C 1231 unless otherwise noted. Because of the violent release of energy stored in pads, the broken cylinder rarely exhibits conical fracture typical of capped cylinders and the sketches of types of fracture in Test Method C39 are not descriptive. . Samples taken in accordance with ASTM C172 where practicable. . When applicable, the following test procedures were used: Slump ASTM C143; Unit Weight ASTM C138; Air Content ASTM C173/ C231; Temperature ASTM C1064 Reports to: Starling Richardson Cons\.; Alln: Eric Stanaland (eps@starlingrichardson.com) KLEIN FELDER Starling Richardson Cons\.; Alln: Andy Munoz (amunoz@starlingrichardson.com) (]# '&rd/h DCCCD Bond Office; Alln: Brenda Spinelli (brenda.spinelli@dcccd.edu) DCCCD Bond Office; AUn: James Williams (james.williams@dcccd.edu) DCCCD Bond Office; AUn: Mike Daniels (mike.daniels@dcccd.edu) F ~oel Peters, P.E. J Jacobs; AUn; Andrea Stogner (Andrea.stogner@jacobs.com) Jacobs; AUn: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; AUn: Larry Davis 1- City of Coppell; AUn: Lee Stone The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested andlor inspected. They are not intended to be indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety.