Loading...
Northlake College-LR071204 K L E I N F E L D E R 2211 Century Center Blvd., Suite 101, Irving, TX 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 IN-PLACE MOISTURE DENSITY TEST RESULTS To: Dallas County Community College Dist. Test Date: 11/30/2007 1505 South Lamar, Suite 1015 Project No: 87015 Dallas, Texas 75215 Report Date: 12/4/2007 Report No: 117563 Project: North Lake College, N Campus Definitions of Terms Location: W Sandy Lake Road @ SH 121 RQP- Rt Qtr Point CL - Centerline Field Rep: S. Wilson LQP - Lt Qtr Point Sta - Station Test Test Location Depth 0 Wet Field Dry Proctor Percent No. Lift 0 Density Moisture Density No. Proctor (%) (pcf) Density Retests , 1 # 5 from report # 117494 Final 116.9 25.7* 93.0 001575 /99.7 2 # 8 from report # 117494 Final 114.4 28.4 89.1 001575 ! 95.5 3 # 3 from report # 117489 Final 119.7 29.1 92.7 001575 99.4 4 # 6 from report # 117507 Final 107.6 33.3 80.7 001559 l 95.2 5 # 7 from report # 117507 Final 107.7 32.6 81.2 001559 95.8 6 # 8 from report # 117507 Final 112.4 31.6 85.4 001609 100.1 7 # 9 from report # 117507 Final 110.3 31.5 83.9 001609 98.4 8 # 11 from report # 117507 Final 115.8 28.5 90.1 001575 96.6 9 # 12 from report # 117507 Final 113.5 27.2 89.2 001575 95.6 \ Proctor No: Description Opt. Moisture Max. Density 001575 Light Brown Clay with Lime 26.5 93.3 001559 Brown Clay with Lime 32.2 84.8 001609 Lime treated brown clay 31.4 85.3 Specs. Gauge No: 28714 Test Methods: ASTM D 2922 Dens. (%) Min 95 Std. Density Count: 2318 ASTM D 3017 Moist. (%) 0+3 Std. Moist Count: 665 ASTM D 698 Trans. Depth (in.): 6 Remarks: Reports to: Starling Richardson Const.; Alln: Eric Stanaland (eps@starlingrichardson.com) Starling Richardson Const.; Alln: Andy Munoz (amunoz@starlingrichardson.com) DCCCD Bond Office; AUn: Brenda Spinelli (brenda.spinelli@dcccd.edu) rWp: DCCCD Bond Office; AUn: James Williams Oames.williams@dcccd.edu) DCCCD Bond Office; AUn: Mike Daniels (mike.daniels@dcccd.edu) / 1'.v1~ Jacobs; AUn: Andrea Stogner (Andrea.stogner@jacobs.com) / Joel Peters, P.E. Jacobs; Alln: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; AUn: Larry Davis 1- City of Coppell; Alln: Lee Stone The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected. They are not intended to be indicative of the qualities of apparently identical products_ The use of our name must receive prior written approval. Reports must be reproduced in their entirety. KLEINFELDER 2211 Century Center Blvd., Suite 101, Irving, Texas 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 REINFORCING STEEL VISUAL OBSERVATIONS TO: Dallas County Community College Dist. 1505 South Lamar, Suite 1015 Dallas, Texas 75215 PROJECT: North Lake College, N Campus W Sandy Lake Road @ SH 121 PROJECT NO: 87015 REPORT DATE: 12/4/2007 REPORT NO.: 117540 Technician: J. Mayo Observation Date: 11/29/2007 Item / Object Observed: o Slab DWall D Grade Beam D Column D Paving D Other Specific Observation Location: Area A and B Referenced Drawing: S6.1, C3 and 02 Results: D Reinforcing steel placed in general accordance with the project drawings. o Exceptions noted and referred to contractor for correction. o Exceptions noted and referred to structural engineer. D Exceptions corrected prior to placement of concrete. Remarks: Incorrect support chairs were used to support top layer of slab reinforcing, resulting in the bars being too low below finished surface. Contractor to make corrections prior to placing concrete. Reports to: Starling Richardson Const.; Attn: Eric Stanaland (eps@starlingrichardson.com) Starling Richardson Const.; Attn: Andy Munoz (amunoz@starlingrichardson.com) DCCCD Bond Office; Attn: Brenda Spinelli (brenda.spinelli@dcccd.edu) DCCCD Bond Office; Attn: James Williams Uames.williams@dcccd.edu) DCCCD Bond Office; Attn: Mike Daniels (mike.daniels@dcccd.edu) Jacobs; Attn: Andrea Stogner (Andrea.stogner@jacobs.com) Jacobs; Attn: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; Attn: Larry Davis 1- City of Coppell; Attn: Lee Stone The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested andlor inspected. They are not intended to be indicative of the qualities of apparentiy identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety. KLEINFELDER Joel Peters, P.E. K L E I N F E L D E R 2211 Century Center Blvd., Suite 101, Irving, TX 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 IN-PLACE MOISTURE DENSITY TEST RESULTS To: Dallas County Community College Dist. Test Date: 12/3/2007 1505 South Lamar, Suite 1015 Project No: 87015 Dallas, Texas 75215 Report Date: 12/4/2007 Report No: 127312 Project: North Lake Colleqe, N Campus Definitions of Terms Location: W Sandy Lake Road @ SH 121 RQP- Rt Qtr Point CL - Centerline Field Rep: J. Mayo LQP - Lt Qtr Point Sta - Station Test Test Location Depth 0 Wet Field Dry Proctor Percent No. Lift 0 Density Moisture Density No. Proctor (%) ( pcf) Density Retests 1 Firelane 45' E and 85' N from SE 6" 108.4 28.4 84.4 001609 98.9 corner 2 Firelane SE entrance 6" 110.7 30.1 85.1 001609 99.8 Proctor No: Description Opt. Moisture Max. Density 001609 Lime treated brown clay 31.4 85.3 Specs. Gauge No: 28714 Test Methods: ASTM D 2922 Dens. (%) Min 95 Std. Density Count: 2289 ASTM D 3017 Moist. (%) +3 Std. Moist Count: 673 ASTM D 698 Trans. Depth (in.): 6 Remarks: Reports to: Starling Richardson Const.; Attn: Eric Stanaland (eps@starlingrichardson.com) Starling Richardson Const.; Attn: Andy Munoz (amunoz@starlingrichardson.com) DCCCD Bond Office; Attn: Brenda Spinelli (brenda.spinelli@dcccd.edu) r:k:'NF~ DCCCD Bond Office; Attn: James Williams Oames.williams@dcccd.edu) DCCCD Bond Office; Attn: Mike Daniels (mike.daniels@dcccd.edu) Jacobs; Attn: Andrea Stogner (Andrea.stogner@jacobs.com) / Joel Peters, P.E. Jacobs; Attn: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; Attn: Larry Davis 1- City of Coppell; Attn: Lee Stone The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested andlor inspected. They are not intended to be Indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety