Loading...
Gateway BP(3.1)-LR071102 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of Reinforcing Steel Inspection Report No.: 303403 Project No.: 0712786 Date of Service: 10/29/2007 Report Date: 11/02/2007 Project: Gateway Business Center Coppell, Texas Services: Reinforcing Steel Inspection Report of Inspection Locations and Items Inspected: Fire lane, west side of building 2 Item s Inspected: Co nfo rming Non Items Inspected: Conforming Non ~ems Inspected: Conforming Non Conforming Co nfo rm ing Conforming P lacing Drawings Bar Length Column Ties Properly Appro ved NA and Shape x Tied and Spaced NA Bar Size x P ra per Bar P laeem ent x Stirrup Spacing NA Bar Grade x ProperlyTied x Stirrup Type NA Bars Clean x Dowel Bars in Place x Lapped Splices x Form Clean x Pro per Bar Suppo rts x CornerBars NA NumberofBars x Proper Cover x Mechanical Splices NA Discrepancies / Comments: No apparent discrepancies were noted at the locations listed above. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and neports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMIKW) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Transwestern Commercial Services 5001 Spring Valley Dallas, TX 75244 Report of Structural Steel Inspection Report No.: 607038 Project No.: 0712786 Date of Service: 10/29/2007 Report Date: 11/02/2007 Project: Gateway Business Center Coppell, Texas Services: Structural Steel Inspection Report of Inspection Service: Perform Structural Steel Inspection as detailed below: Drawings Utilized: Structural Locations and Items Inspected: Buildings 1 and 2, lobby, stairs Discrepancies / Comments: 1. Building 1: Column anchor bolts loose, welds not deslagged at all locations and stair landing welds need to be welded and ground to AESS as per AISC specifications. Need RFI for "as-built" at 2nd floor elevation. Non-compliant. Need two anchors at buildings 1 and 2, bottom of stairs. 2. Building 2: Column anchor bolts missing or loose, stair landing splice welds need to be ground per AESS, AISC specifications. Need RFI for "as built" condition at landing and 2nd floor elevation. Non-compliant. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 1 of 2