Gateway BP(3.1)-LR071112
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
Report of Reinforcing Steel Inspection
Report No.: 304697
Project No.: 0712786
Date of Service: 11/07/2007
Report Date: 11/12/2007
Project: Gateway Business Center
Coppell, Texas
Services: Reinforcing Steel Inspection
Report of Inspection
Locations and Items Inspected:
1. Paving for parking area, southwest side of building 2.
2. Paving between buildings 1 and 2.
3. Parking area, southeast from corner of building 2,
ijem sins pected: Co nfo rm ing Non ijems Inspected: Conforming Non Item sins pected: Conforming Non
Conforming Conforming Co nfo rm ing
Placing Drawings Bar Length ColumnTies Properly
Appro ved x and Shape x Tied and Spaced NA
Bar Size x Pro per Bar Placement x Stirrup Spacing NA
Bar Grade x Pro perly Tied x S lirrup Type NA
8 ars C iean x Dowel Bars in Place x Lapped Splices x
Form Clean x Pro per B ar Suppo rts x CornerBars NA
Numberof Bars x ProperCover x Mechanical Splices NA
Discrepancies I Comments:
1. Remove loose debris from placement area.
2. Steel supports needed.
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMIED) Page 1 of 2
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
Report of Structural Steel Inspection
Report No.: 607075
Project No.: 0712786
Date of Service: 11/05/2007
Report Date: 11/12/2007
Project: Gateway Business Center
Coppell, Texas
Services: Structural Steel Inspection
Report of Inspection
III. Building 2
1. Column anchor bolt at stair installed, bolts tensioned. Item cleared from report #607038, dated 10/29/07 (bolts only).
IV. Splice at landing has downward weld progression (non-compliant).
V. Building 1
1. Column anchor bolts at stair, discrepancy is corrected and cleared from the noted report (bolts only).
LIMIT A nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMIED) Page 2 of 3
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
Report of Structural Steel Inspection
Report No.: 607075
Project No.: 0712786
Date of Service: 11/05/2007
Report Date: 11/12/2007
Project: Gateway Business Center
Coppell, Texas
Services: Structural Steel Inspection
Report of Inspection
Service: Perform Structural Steel Inspection as detailed below:
Drawings Utilized: Structural
Locations and Items Inspected: Visual re-inspection as noted below, buildings 1 and 2
Discrepancies:
I. Building 1
1. Bridging missing welds.
2. Girders not welded at expansion joint fixed end.
3. Girder at tilt wall discrepancies not corrected where the bearing seat was torch cut off.
4. Joist bearing seat at tilt wall previously noncompliant areas not addressed.
5. Joist bearing seat at tilt wall missing bolt at slip joint.
II. Building 2
1. Girders not welded at required locations, expansion joint fixed end and girder to column.
2. Bolted roof framing bolts not snapped (T.C. bolts) at required locations, loose, mising bolts.
3. Bridging not welded where required.
4. Girder at tilt wall bearing plate torch cut off at panel.
5. Bottom chord stabilization not welded.
6. Joist at columns not bearing, has 5" gap from bearing seat to the bottom of joist, RFI required.
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMIED) Page 1 of 3
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
Report of Reinforcing Steel Re-Inspection
Report No.: 304765
Project No.: 0712786
Date of Service: 11/08/2007
Report Date: 11/12/2007
Project: Gateway Business Center
Coppell, Texas
Services: Reinforcing Steel Re-Inspection
Report of Re-Inspection
Locations and Items Inspected:
1. Paving for parking area, southwest side of building 2.
2. Paving between buildings 1 and 2.
3. Paving off southeast corner of building 2.
nems Inspected: Conforming Non Items Inspected: Co nfo rm ing Non nems Inspected: Conforming Non
Conforming Conforming Conforming
P iac ing Drawings Bar Length Column Ties Properly
Approved x and Shape x Tied and Spaced NA
Bar Size x P [0 per B ar P lacem ent x Stirrup Spacing NA
Bar Grade x Properly Tied x Stirrup Type NA
Bars Clean x Dowel Bars in Place x Lapped Splices x
Form Ciean x Proper B ar Supports x Corner Bars NA
NumberofBars x ProperCover x Mechanical Splices NA
Discrepancies I Comments: All items listed on the previous report have been corrected and cleared to
compliant status.
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMlED) Page 1 of 2
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
Report of Reinforcing Steel Inspection
Report No.: 304466
Project No.: 0712786
Date of Service: 11/06/2007
Report Date: 11/12/2007
Project: Gateway Business Center
Coppell, Texas
Services: Reinforcing Steel Inspection
Report of Inspection
Locations and Items Inspected:
Approach off Freeport Pkwy., Station 527+00, first approach northobund
from 1635 from Freeport Pkwy. And stairs in buildings 1 and 2.
Ilem sins pecled: Co nfo rm ing Non Ilem s Inspecled: Conforming Non Ilem sins pecled: Co nfo rm ing Non
Conforming Co nfo rm ing Conforming
Placing Drawings 8 ar Length Column Ties Properly
Appro ved x and Shape x Tied and Spaced NA
8 ar Size x Pro per 8 ar P lacem ent x Stirrup Spacing NA
8arGrade x Pro perly Tied x Stirrup Type NA
8ars Clean x Dowel Bars in Place x Lapped Splices x
Form Clean x P ra per 8 ar Suppa rts x Corner Bars NA
Numberof Bars x ProperCaver x Mechanical Splices NA
Discrepancies J Comments: 1. Remove debris from placement area.
2. Add chair risers.
Discrepancies noted above were corrected prior to concrete placement.
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMIED) Page 1 of 2
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
Report of Reinforcing Steel Inspection
Report No.: 304101
Project No.: 0712786
Date of Service: 11/02/2007
Report Date: 11/12/2007
Project: Gateway Business Center
Coppell, Texas
Services: Reinforcing Steel Inspection
Report of Inspection
Locations and Items Inspected:
Fire lane and parking area, north side if building 2
"ems Inspected: Conforming Non Items Inspected: Conforming Non "ems Inspected: Co nfo rm jng Non
Conforming Conforming Co nfo rm ing
Placing Drawings Bar Length Column Ties Properly
Approved x and Shape x Tied and Spaced NA
Bar Size x Pro per B ar P lacem ent x Stirrup Spacing NA
Bar Grade x Properly Tied x Stirrup Type NA
Bars Clean x Dowel Bars in Place x Lapped Splices x
Form Clean x Proper Bar Supports x Corner Bars NA
Numberof Bars x Proper Cover x Mechanical Splices NA
Discrepancies / Comments: 1. Remove trash and debris from placement area. 2. Manhole required diagonal bars.
3. Dowels were bent. 4. Additional chairs needed.
Discrepancies noted above were corrected prior to concrete placement.
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMIED) Page 1 of 2
Rone En~==
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
Report of In-Place Density Testing
Report No.: 304642
Project No.: 0712786
Date of Service: 11/07/2007
Report Date: 11/12/2007
Project: Gateway Business Center
Coppell, Texas
Services: Perform In-Place Density Testing
PROJECT DATA
Contractor: Constructors & Associates
Test Method: ASTM 0-6938
Gauge: Troxler 3430
Gauge Serial No: 35518
Test Mode: DT
Standard Counts
Moisture Density
Current: 730 Current: 2522
Previous: 742 Previous: 2526
MOISTURE DENSITY RELATIONS
MID No.
277809
Description
Moisture
%
Maximum
Density
(pef)
89.0
Project Requirements
Moisture Density
Optimum +4 95 min
Dark Brown I Clay
27.0
Test
No
Test Location
Paving subgrade
Center of fire lane between building 1 and 2
FIELD DENSITY TESTS
Probe MID
Depth No.
Moisture
%
Wet Density Dry Density Density
(pef) (pef) (% max)
1
6" 277809
30.2
111.7
85.8
96
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 1 of 2