Loading...
Duke Lesley-LR071217 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 302353 Project No.: 0612510 Date of Service: 10/18/2007 Report Date: 12/17/2007 Project: Lesley Infrastructure Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Concrete Supplier: TXI Plant: 141 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 4.0 Mix Design I.D.: 88274 Placement Date: 10/18/2007 Weather Conditions: Sunny, clear Time Sampled: 09:36am Batch time: 08:29am Temperature - Air: 680F Concrete: 800F Truck No: 1071 Ticket No: 553851 Air Content: 3.3% Unit Weight (pet): NA Overall Placement Location: Crosswalks - on Dividend Drive and East Point West Street, Station 33+91 Sample Location: East Point West, Station 33+91.30 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 10/25/2007 7 6.00 28.27 121,740 4,310 Cone/Split 1 2 11/15/2007 28 6.00 28.27 115,684 4,090 Cone/Split 1 3 11/15/2007 28 6.00 28.27 155,350 5,490 Cone/Shear Average 4,790 4 12/13/2007 56 6.00 28.27 167,710 5,930 Cone/Split Remarks: Water added at site: 5 gallons Started: 08:15am Finished: 10:45am Technician: Javier Martinez Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Alex Bennett PE (1-ec copy) 1-ec Lacy Construction Attn: Mr. Kevin Briles 1-cc City of Coppell Attn: Mr. Lee Stone 1-cc City of Coppell Attn: Mr. Larry Davis Rone Engineering p~ ~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter prOVided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 1 of 1