Duke Lesley 2A-LR071126
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 299952
Project No.: 0712932
Date of Service: 09/26/2007
Report Date: 11/26/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 3,000 psi @ 28 days
Slump (in.): NA
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7751 PW
Placement Date: 09/26/2007
Weather Conditions: Partly Cloudy
Time Sampled: 09:20am Batch time: 08:39am
Temperature - Air: 790F Concrete: 860F
Truck No: 107 Ticket No: 7823
Air Content: NA Unit Weight (pet): NA
Overall Placement Location:
Building piers 24.8-20.2/L - 10 piers, 1 pier cap at B/27-27.1
Measured
Slump
(inches)
7.25
Sample Location:
Building pier U24.8
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
1 1 10/03/2007 7 6.00 28.27 57,540 2,040 Cone/Split
1 2 10/03/2007 7 6.00 28.27 59,940 2,120 Shear
Average 2,080
1 3 10/24/2007 28 6.00 28.27 76,950 2,720 Cone/Split
1 4 10/24/2007 28 6.00 28.27 86,770 3,070 Cone/Split
Average 2,900 *
1 5 11/21/2007 56 6.00 28.27 96,450 3,410 Cone/Shear
* Does not comply with specified strength
Technician: Chris Harbour Rone Engineering
See Report 299951 for technician timeA ~
Report Distribution: .... ~~
Orig' Doke Co",l,"olloo, IP (D.".., TX) All" M,. P,"' Byrne . - - ,- - -~ = -=-----'
(1-ec copy) - - -
1-cc Potter Concrete Altn: Mr Ryan Skelly K. Scoll Watson, AET
1-cc C~ty of Coppell Attn: Mr. Lee Stone. Project Manager
1-cc CIty of Coppell AUn: Mr. Larry DavIs
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, LId.
(LB/KW) Page 1 of 1
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7101 W Little York, Ste 600, Houston, TX 71040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 299967
Project No.: 0712932
Date of Service: 09/26/2007
Report Date: 11/26/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9349
Placement Date: 09/26/2007
Weather Conditions: Cloudy, calm
Time Sampled: 03:30am Batch time: 03:18am
Temperature - Air: 700F Concrete: 820F
Truck No: 129 Ticket No: 7771
Air Content: 0.5% Unit Weight (pet): NA
Overall Placement Location:
Slab on grade, grid lines E-G/11-21 (west)
Measured
Slump
(inches)
5.0
Sample Location:
Grid line E/11.5
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
1 1 10/03/2007 7 6.00 28.27 85,160 3,010 Cone/Split
1 2 10/24/2007 28 6.00 28.27 117,770 4,170 Cone/Shear
1 3 10/24/2007 28 6.00 28.27 124,390 4,400 Cone/Split
Average 4,280
1 4 11/21/2007 56 6.00 28.27 125,690 4,450 Cone/Split
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/KW) Page 1 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 299967
Project No.: 0712932
Date of Service: 09/26/2007
Report Date: 11/26/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9349
Placement Date: 09/26/2007
Weather Conditions: Cloudy, calm
Time Sampled: 04:15am Batch time: 03:59am
Temperature - Air: 710F Concrete: 800F
Truck No: 107 Ticket No: 7779
Air Content: 0.4% Unit Weight (pcf): NA
Overall Placement Location:
Slab on grade, grid lines E-G/11-21 (west)
Measured
Slump
(inches)
5.0
Sample Location:
Grid line E.8/12.2
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
2 1 10/03/2007 7 6.00 28.27 71,650 2,530 Cone/Shear
2 2 10/24/2007 28 6.00 28.27 96,510 3,410 Shear
2 3 10/24/2007 28 6.00 28.27 91,330 3,230 Shear
Average 3,320 *
2 4 11/21/2007 56 6.00 28.27 124,610 4,410 Cone/Split
* Does not comply with specified strength
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/KW) Page 2 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 299967
Project No.: 0712932
Date of Service: 09/26/2007
Report Date: 11/26/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9349
Placement Date: 09/26/2007
Weather Conditions: Cloudy, calm
Time Sampled: 04:40am Batch time: 04:36am
Temperature - Air: 740F Concrete: 820F
Truck No: 107 Ticket No: 7786
Air Content: 0.6% Unit Weight (pcf): NA
Overall Placement Location:
Slab on grade, grid lines E-G/11-21 (west)
Measured
Slump
(inches)
5.5
Sample Location:
Grid line F.2/13.8
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
3 1 10/03/2007 7 6.00 28.27 94,740 3,350 Cone/Split
3 2 10/24/2007 28 6.00 28.27 121,630 4,300 Shear
3 3 10/24/2007 28 6.00 28.27 126,850 4,490 Cone/Split
Average 4,390
3 4 11/21/2007 56 6.00 28.27 139,690 4,940 Cone/Split
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/KW) Page 3 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 299967
Project No.: 0712932
Date of Service: 09/26/2007
Report Date: 11/26/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1 064
ASTM C-138
ASTM C-39
PROJECT OAT A
Mix Design 1.0.: 9349
Placement Date: 09/26/2007
Weather Conditions: Cloudy, calm
Time Sampled: 06:00am Batch time: 05:33am
Temperature - Air: 750F Concrete: 890F
Truck No: 141 Ticket No: 7798
Air Content: 0.6% Unit Weight (pcf): NA
Overall Placement Location:
Slab on grade, grid lines E-G/11-21 (west)
Measured
Slump
(inches)
5.0
Sample Location:
Grid line E.2/14.5
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
4 1 10/03/2007 7 6.00 28.27 94,460 3,340 Cone/Shear
4 2 10/24/2007 28 6.00 28.27 127,900 4,520 Cone/Shear
4 3 10/24/2007 28 6.00 28.27 122,670 4,340 Cone/Split
Average 4,430
4 4 11/21/2007 56 6.00 28.27 137,290 4,860 Cone/Shear
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/KW) Page 4 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 299967
Project No.: 0712932
Date of Service: 09/26/2007
Report Date: 11/26/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1 064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9349
Placement Date: 09/26/2007
Weather Conditions: Cloudy, calm
Time Sampled: 07:30am Batch time: 06:54am
Temperature - Air: 710F Concrete: 800F
Truck No: 129 Ticket No: 7806
Air Content: 0.3% Unit Weight (pcf): NA
Overall Placement Location:
Slab on grade, grid lines E-G/11-21 (west)
Measured
Slump
(inches)
5.5
Sample Location:
Grid line G/15.2
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
5 1 10/03/2007 7 6.00 28.27 105,500 3,730 Cone/Split
5 2 10/24/2007 28 6.00 28.27 143,610 5,080 Shear
5 3 10/24/2007 28 6.00 28.27 141,040 4,990 Cone/Split
Average 5,030
5 4 11/21/2007 56 6.00 28.27 154,860 5,480 Shear
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/KW) Page 5 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 299967
Project No.: 0712932
Date of Service: 09/26/2007
Report Date: 11/26/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Req u i rements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9349
Placement Date: 09/26/2007
Weather Conditions: Cloudy, calm
Time Sampled: 08:46am Batch time: 08:19am
Temperature - Air: 800F Concrete: 880F
Truck No: 128 Ticket No: 7820
Air Content: 0.3% Unit Weight (pet): NA
Overall Placement Location:
Slab on grade, grid lines E-G/11-21 (west)
Measured
Slump
(inches)
5.0
Sample Location:
Grid line E.8/16.3
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
6 1 10/03/2007 7 6.00 28.27 103,930 3,680 Cone/Split
6 2 10/24/2007 28 6.00 28.27 130,360 4,610 Cone/Split
6 3 10/24/2007 28 6.00 28.27 133,740 4,730 Shear
Average 4,670
6 4 11/21/2007 56 6.00 28.27 146,760 5,190 Shear
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/KW) Page 6 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 299967
Project No.: 0712932
Date of Service: 09/26/2007
Report Date: 11/26/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 9349
Placement Date: 09/26/2007
Weather Conditions: Cloudy, calm
Time Sampled: 10:50am Batch time: 10:24am
Temperature - Air: 780F Concrete: 900F
Truck No: 141 Ticket No: 7837
Air Content: 0.6% Unit Weight (pcf): NA
Overall Placement Location:
Slab on grade, grid lines E-G/11-21 (west)
Measured
Slump
(inches)
5.5
Sample Location:
Grid line E.6/17
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
7 1 10/03/2007 7 6.00 28.27 104,180 3,680 Shear
7 2 10/24/2007 28 6.00 28.27 124,000 4,390 Shear
7 3 10/24/2007 28 6.00 28.27 132,390 4,680 Cone/Split
Average 4,530
7 4 11/21/2007 56 6.00 28.27 149,970 5,300 Cone/Split
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/KW) Page 7 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 299967
Project No.: 0712932
Date of Service: 09/26/2007
Report Date: 11/26/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required lesting, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Spt#cification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9349
Placement Date: 09/26/2007
Weather Conditions: Cloudy, calm
Time Sampled: 11 :30am Batch time: 10:55am
Temperature - Air: 850F Concrete: 900F
Truck No: 103 Ticket No: 7843
Air Content: 0.7% Unit Weight (pcf): NA
Overall Placement Location:
Slab on grade, grid lines E-G/11-21 (west)
Measured
Slump
(inches)
6.0
Sample Location:
Grid line F/18.5
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
8 1 10/03/2007 7 6.00 28.27 97,440 3,450 Cone/Split
8 2 10/24/2007 28 6.00 28.27 128,740 4,550 Cone/Split
8 3 10/24/2007 28 6.00 28.27 124,230 4,390 Cone/Split
Average 4,470
8 4 11/21/2007 56 6.00 28.27 144,530 5,110 Cone/Split
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition. appearance, etc.) or any other feature of similar sUbject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/KW) Page 8 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrlch, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 299967
Project No.: 0712932
Date of Service: 09/26/2007
Report Date: 11/26/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 9349
Placement Date: 09/26/2007
Weather Conditions: Cloudy, calm
Time Sampled: 12:00pm Batch time: 11:41am
Temperature - Air: 850F Concrete: 900F
Truck No: 128 Ticket No: 7852
Air Content: 0.4% Unit Weight (pcf): NA
Overall Placement Location:
Slab on grade, grid lines E-G/11-21 (west)
Measured
Slump
(inches)
6.0
Sample Location:
Grid line E/19.5
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
9 1 10/03/2007 7 6.00 28.27 98,680 3,490 Cone/Split
9 2 10/24/2007 28 6.00 28.27 127,700 4,520 Cone/Split
9 3 10/24/2007 28 6.00 28.27 134,280 4,750 Shear
Average 4,630
9 4 11/21/2007 56 6.00 28.27 134,360 4,750 Shear
Technician: David Best Started: 02:30am
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne
(1-ec copy)
1-cc Potter Concrete Alln: Mr Ryan Skelly
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
Finished: 03:00pm Rone Engineering
~~~
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/KW) Page 9 of 9