Duke Lesley 2A-LR071203 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Reinforcing Steel Inspection Report No.: 306563 Project No.: 0712932 Date of Service: 11/28/2007 Report Date: 12/03/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Reinforcing Steel Inspection Report of Inspection Locations and Items Inspected: Paving, fire lane from Dividend Drive to west side of building. Item s Inspected: Confo rm Ing Non Items Inspected: Conforming Non Item sins pected: Conforming Non Co nfo rm ing Conforming Co nfo rm ing P lacing Drawings Bar Length Column Ties Properly Appro ved x and Shape x Tied and Spaced NA BarSize x Pro per B ar P lacem ent x Stirrup Spacing NA Bar Grade x Pro perly Tied x Stirrup Type NA Bars Clean x Dowel Bars in Place x Lapped Splices x Form Clean x Pro per B ar Suppo rts NA CornerBars NA Numberof Bars x ProperCover NA Mechanical Splices NA Discrepancies / Comments: 1. Chairs to be installed during concrete placement. Technician: Chris Harbour Started: 01 :OOpm Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne (1-ec copy) 1-cc City of Coppell Alln: Mr. Lee Stone 1-cc City of Coppell Alln: Mr. Larry Davis Finished: 02:45pm Rone Engineering ft~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMfKW) Page 1 of 1 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Concrete Compressive Strength Test Report No.: 303625 Project No.: 0712932 Date of Service: 10/31/2007 Report Date: 12/03/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Redi Mix Plant: 136 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 340K1501 Placement Date: 10/31/2007 Weather Conditions: Clear Time Sampled: 06:40am Temperature - Air: 500F Truck No: 1184 Air Content: NA Overall Placement Location: Panels at Point West VII (panels 42-43, 45-55, 57-58) Batch time: 06:09am Concrete: 800F Ticket No: 13600659 Unit Weight (pcf): NA Measured Slump (inches) 5.5 Sample Location: Panel 42 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 11/07/2007 7 6.00 28.27 88,640 3,130 Cone/Split 1 2 11/28/2007 28 6.00 28.27 118,190 4,180 Cone/Split 1 3 11/28/2007 28 6.00 28.27 124,740 4,410 Shear Average 4,300 4 12/26/2007 56 Remarks: Water added at site: 10 gallons LIMIT A nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition; appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (JBILB) Page 1 of 4 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 303625 Project No.: 0712932 Date of Service: 10/31/2007 Report Date: 12/03/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Redi Mix Plant: 136 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design \.0.: 340K1501 Placement Date: 10/31/2007 Weather Conditions: Sunny, clear Time Sampled: 08:00am Batch time: 07:34am Temperature - Air: 600F Concrete: 800F Truck No: 1184 Ticket No: 13600679 Air Content: NA Unit Weight (pct): NA Overall Placement Location: Panels at Point West VII (panels 42-43,45-55,57-58) Measured Slump (inches) 5.0 Sample Location: Panel 45 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 2 1 11/07/2007 7 6.00 28.27 97,060 3,430 Cone/Split 2 2 11/28/2007 28 6.00 28.27 122,890 4,350 Cone/Split 2 3 11/28/2007 28 6.00 28.27 119,380 4,220 Cone/Split Average 4,280 2 4 12/26/2007 56 Remarks: Water added at site: 10 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar sUbject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (JB/lS) Page 2 of 4 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 303625 Project No.: 0712932 Date of Service: 10/31/2007 Report Date: 12/03/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Redi Mix Plant: 136 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 340K1501 Placement Date: 10/31/2007 Weather Conditions: Sunny, clear Time Sampled: Batch time: 06:09am Temperature - Air: 650F Concrete: 860F Truck No: 1008 Ticket No: 1300692 Air Content: NA Unit Weight (pet): NA Overall Placement Location: Panels at Point West VII (panels 42-43, 45-55, 57-58) Measured Slump (inches) 5.75 Sample Location: Panel 48 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 3 1 11/07/2007 7 6.00 28.27 86,570 3,060 Cone/Split 3 2 11/28/2007 28 6.00 28.27 132,290 4,680 Cone/Split 3 3 11/28/2007 28 6.00 28.27 121 , 130 4,280 Cone/Split Average 4,480 3 4 12/26/2007 56 LIMIT A nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (JB/LB) Page 3 of 4 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 303625 Project No.: 0712932 Date of Service: 10/31/2007 Report Date: 12/03/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Redi Mix Plant: 136 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 340K1501 Placement Date: 10/31/2007 Weather Conditions: Clear Time Sampled: 10:45am Temperature - Air: 650F Truck No: 1039 Air Content: NA Overall Placement Location: Panels at Point West VII (panels 42-43, 45-55, 57-58) Measured Slump (inches) 5.5 Batch time: 10:02am Concrete: 860F Ticket No: 13600711 Unit Weight (pcf): NA Sample Location: Panel 54 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (inZ) (Ibs) (psi) Type 4 1 11/07/2007 7 6.00 28.27 89,840 3,180 Cone/Split 4 2 11/28/2007 28 6.00 28.27 118,740 4,200 Shear 4 3 11/28/2007 28 6.00 28.27 125,480 4,440 Shear Average 4,320 4 4 12/26/2007 56 Technician: Montreal Bailey Started: 05:00am Report Distribution: Orig: Duke Construction, LP (Dallas, TX) AUn: Mr. Paul Byrne (1-ec copy) 1-cc Potter Concrete AUn: Mr Ryan Skelly 1-cc City of Coppell Alln: Mr. Lee Stone 1-cc City of Coppell Alln: Mr. Larry Davis Finished: 123:J;;;ij K. Scott Watson, AET Project Manager ~ LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no contnol. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (JB/LB) Page 4 of 4 Rone Eni~ 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Reinforcing Steel Inspection Report No.: 306828 Project No.: 0712932 Date of Service: 11/30/2007 Report Date: 12/03/2007 Project: Hemisphere's at Point West Coppell, Texas Services: Reinforcing Steel Inspection Report of Inspection Locations and Items Inspected: Wall for ramp, grid lines Ll2?? to 25' south Item s Inspected: Co nfo rm ing Non Item s Inspected: C onfo rm ing Non ~em s Inspected: Confo rm ing Non Co nfo rm ing Conforming Conforming Placing 0 rawings Bar Length Column Ties Properly Approved x and Shape x Tied and Spaced NA BarSize x P fO per B ar P lacem ant x Stirrup Spacing NA Bar Grade x Pro perly Tied x Stirrup Type NA Bars Clean x Dowel Bars in Place x Lapped Splices x Form Clean x Pro per B ar Suppo rts x CamerBars NA Number of Bars x ProperCover x Mechanical Splices NA Discrepancies / Comments: 1. Bars touching forms in various areas. Discrepancies noted above were corrected prior to concrete placement. Technician: Ben Weaverling Started: 10:00am Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne (1-ec copy) 1-cc City of Coppell Attn: Mr. Lee Stone 1-cc City of Coppell Attn: Mr. Larry Davis Finished: 11:45am Rone Engineering ,~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services. Ltd. (TM/KW) Page 1 of 1