Duke Lesley 2A-LR071206
Rone Engineering
..
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Reinforcing Steel Inspection
Report No.: 307094
Project No.: 0712932
Date of Service: 12/03/2007
Report Date: 12/06/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Reinforcing Steel Inspection
Report of Inspection
Locations and Items Inspected:
Paving, fire lane and parking lot, northwest corner of building towards
northeast corner, halfway.
lIem s Inspected: Conforming Non Item s Inspected: Co nfo rm ing Non lIems Inspected: Co nfo rm ing Non
Co nforming Conforming Conforming
P lacing Drawings Bar Length Column Ties Properly
Appro ved x and Shape x Tied and Spaced NA
Bar Size x Pro per Bar P lacem ent x Stirrup Spacing NA
Bar Grade x Pro perty Tied x Stirrup Type NA
Bars Clean x Dowel Bars in Place x Lapped Splices x
Form Clean x Proper Bar Suppa rts x Co mer Bars NA
Number of Bars x Proper Cover x M echanicaJ Splices NA
Discrepancies / Comments:
1. Tie down steel at various locations. 2. Add chairs. 3. Missing corner bars.
Discrepancies noted above were corrected prior to concrete placement.
Technician: Jose Villanueva Started: 04:30pm
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne
(1-ec copy)
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell AUn: Mr. Larry Davis
Finished: 06:00pm Rone Engineering
p~
~
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/JB) Page 1 of 1