Duke Lesley 2A-LR071211
Rone En~==
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 303893
Project No.: 0712932
Date of Service: 11/01/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 7753 PW
Placement Date: 11/01/2007
Weather Conditions: Clear
Time Sampled: 05:20am
Temperature - Air: 460F
Truck No: 106
Air Content: 4.3%
Overall Placement Location:
Paving at Point West V11 (Northwest corner orf trailer parking traveling west into
street)
Batch time: 04:59am
Concrete: 800F
Ticket No: 8679
Unit Weight (pet): NA
Measured
Slump
(inches)
5.75
Sample Location:
30' north, 10' west from southeast corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 11/08/2007 7 6.00 28.27 81 ,190 2,870 Cone/Shear
1 2 11/29/2007 28 6.00 28.27 118,330 4,190 Shear
1 3 11/29/2007 28 6.00 28.27 119,810 4,240 Shear
Average 4,210
1 4 12/27/2007 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 1 of 6
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303893
Project No.: 0712932
Date of Service: 11/01/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Batch time: 06:41 am
Concrete: 800F
Ticket No: 8689
Unit Weight (pcf): NA
Measured
Slump
(inches)
5.0
Mix Design 1.0.: 7753 PW
Placement Date: 11/01/2007
Weather Conditions: Clear
Time Sampled: 07:00am
Temperature - Air: 500F
Truck No: 107
Air Content: 4.5%
Overall Placement Location:
Paving at Point West V11 (Northwest corner orf trailer parking traveling west into
street)
Sample Location:
75' north, 20' west from southeast corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
2 1 11/08/2007 7 6.00 28.27 86,550 3,060 Cone/Split
2 2 11/29/2007 28 6.00 28.27 142,960 5,060 Cone/Split
2 3 11/29/2007 28 6.00 28.27 138,410 4,900 Cone/Shear
Average 4,980
2 4 12/27/2007 56
Remarks: Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 2 of 6
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303893
Project No.: 0712932
Date of Service: 11/01/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
5.5
Mix Design I.D.: 7753 PW
Placement Date: 11/01/2007
Weather Conditions: Sunny, clear
Time Sampled: 08:10am Batch time: 07:49am
Temperature - Air: 550F Concrete: 820F
Truck No: 141 Ticket No: 8698
Air Content: 4.6% Unit Weight (pet): NA
Overall Placement Location:
Paving at Point West V11 (Northwest corner orf trailer parking traveling west into
street)
Sample Location:
11 0' north, 40' west from southeast corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
3 1 11/08/2007 7 6.00 28.27 109,620 3,880 Cone/Split
3 2 11/29/2007 28 6.00 28.27 159,980 5,660 Cone/Split
3 3 11/29/2007 28 6.00 28.27 164,290 5,810 Cone/Split
Average 5,730
3 4 12/27/2007 56
Remarks: Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be repnoduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 3 of 6
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303893
Project No.: 0712932
Date of Service: 11/01/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
5.75
Mix Design 1.0.: 7753 PW
Placement Date: 11/01/2007
Weather Conditions: Sunny, partly cloudy
Time Sampled: 09:30am Batch time: 09:13am
Temperature - Air: 600F Concrete: 850F
Truck No: 106 Ticket No: 8707
Air Content: 4.4% Unit Weight (pet): NA
Overall Placement Location:
Paving at Point West V11 (Northwest corner orf trailer parking traveling west into
street)
Sample Location:
180' north, 15' west from southeast corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
4 1 11/08/2007 7 6.00 28.27 113,960 4,030 Cone/Split
4 2 11/29/2007 28 6.00 28.27 159,110 5,630 Cone/Split
4 3 11/29/2007 28 6.00 28.27 163,670 5,790 Cone/Split
Average 5,710
4 4 12/27/2007 56
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar SUbject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 4 of 6
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 303893
Project No.: 0712932
Date of Service: 11/01/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design I.D.: 7753 PW
Placement Date: 11/01/2007
Weather Conditions: Sunny, partly cloudy
Time Sampled: 11 AOam Batch time: 11 :28am
Temperature - Air: 600F Concrete: 860F
Truck No: 127 Ticket No: 15453
Air Content: 4.1 % Unit Weight (pet): NA
Overall Placement Location:
Paving at Point West V11 (Northwest corner orf trailer parking traveling west into
street)
Measured
Slump
(inches)
5.0
Sample Location:
250' north, 5' west from southeast corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
5 1 11/08/2007 7 6.00 28.27 91,110 3,220 Cone/Split
5 2 11/29/2007 28 6.00 28.27 135,920 4,810 Cone/Split
5 3 11/29/2007 28 6.00 28.27 136,860 4,840 Cone/Split
Average 4,820
5 4 12/27/2007 56
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 5 of 6
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 303893
Project No.: 0712932
Date of Service: 11/01/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 7753 PW
Placement Date: 11/01/2007
Weather Conditions: Sunny, partly cloudy
Time Sampled: 12:15pm Batch time: 11:59am
Temperature - Air: 650F Concrete: 860F
Truck No: 106 Ticket No: 8721
Air Content: 4.0% Unit Weight (pct): NA
Overall Placement Location:
Paving at Point West V11 (Northwest corner orf trailer parking traveling west into
street)
Measured
Slump
(inches)
5.25
Sample Location:
300' north, 25' west from southeast corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
6 1 11/08/2007 7 6.00 28.27 91,980 3,250 Cone/Split
6 2 11/29/2007 28 6.00 28.27 137.710 4,870 Cone/Split
6 3 11/29/2007 28 6.00 28.27 134,880 4,770 Cone/Split
Average 4,820
6 4 12/27/2007 56
Remarks: Water added at site: 5 gallons
Technician: Montreal Bailey
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne
(1-ec copy)
1-cc Potter Concrete Attn: Mr Ryan Skelly
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
Started: 04:45am Finished: 02:30pm
Rone Engineering
P-~ ;::;>
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CHfED) Page 6 of 6
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304416
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 5,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9385
Placement Date: 11/05/2007
Weather Conditions: Sunny, clear
Time Sampled: 02:15pm Batch time: 01:44pm
Temperature - Air: 820F Concrete: 920F
Truck No: 130 Ticket No: 8847
Air Content: NA Unit Weight (pcf): NA
Overall Placement Location:
Panels
Measured
Slump
(inches)
4.0
Sample Location:
Panel P-56
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 11/08/2007 3 6.00 28.27 105,310 3,720 Cone/Split
1 2 11/12/2007 7 6.00 28.27 127,990 4,530 Cone/Split
1 3 12/03/2007 28 6.00 28.27 155,000 5,480 Cone/Split
1 4 12/03/2007 28 6.00 28.27 162,220 5,740 Cone/Split
Average 5,610
1 5 12/31/2007 56
Technician: Montreal Bailey Rone Engineering
See Report 304290 for technician time~ ~
Report Distribution: . ~.
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne . . _ . _
(1-ec copy) - -
1-cc P?tter Concrete Attn: Mr Ryan Skelly K. Scott Watson, AET
1-cc City of Coppell Attn: Mr. Lee Stone P . ct M
.' roJe anager
1-cc City of Coppell Attn: Mr. Larry DavIs
~
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMlED) Page 1 of 1
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, 8te 600, Houston, TX 77040
4421 Freidrich, 8te 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 301922
Project No.: 0712932
Date of Service: 10/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 3,000 psi @ 28 days
Slump (in.): NA
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 7751 PW
Placement Date: 10/12/2007
Weather Conditions: Clear
Time Sampled: 11 :20am
Temperature - Air: 760F
Truck No: 125
Air Content: NA
Overall Placement Location:
Building piers Al1.95, 2.4, 3, 3.3, 3.B, 4.2, 4.B, 5.2, 5.B, 6.2
Batch time: 1 0:48am
Concrete: 800F
Ticket No: 14800
Unit Weight (pcf): NA
Measured
Slump
(inches)
6.25
Sample Location:
Same as above
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
1 1 10/19/2007 7 6.00 28.27 89,850 3,180 Shear
1 2 10/19/2007 7 6.00 28.27 93,620 3,310 Shear
Average 3,240
1 3 11/09/2007 28 6.00 28.27 117,740 4,160 Shear
1 4 11/09/2007 28 6.00 28.27 131,670 4,660 Cone/Split
Average 4,410
1 5 12/07/2007 56 6.00 28.27 132,270 4,680 Cone/Split
Remarks: Water added at site: 25 gallons (before sample by Potter Concrete)
Technician: Chris Harbour Rone Engineering
See Report 301921 for technician time~~
Report Distribution: . . ...~
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne . .. ... ~
(1-eccopy) -
1-cc P~tter Concrete Attn: Mr Ryan Skelly K. Scott Watson, AET
1-cc City of Coppell Attn: Mr. Lee Stone P .ect Mar
1-cc City of Coppell Attn: Mr. Larry Davis roJ an ge
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, LId.
(CH/ED) Page 1 of 1
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 305138
Project No.: 0712932
Date of Service: 11/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753 PW
Placement Date: 11/12/2007
Weather Conditions: Cloudy, light wind
Time Sampled: 03:05am Batch time: 02:50am
Temperature - Air: 620F Concrete: 750F
Truck No: 140 Ticket No: 925
Air Content: 4.4% Unit Weight (pet): NA
Overall Placement Location:
Paving _ southwest section of south parking lot, south side of building 7
Measured
Slump
(inches)
5.0
Sample Location:
130' east, 75' south from southwest corner of building 7
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 11/19/2007 7 6.00 28.27 111,590 3,950 Cone/Split
1 2 12/10/2007 28 6.00 28.27 148,750 5,260 Shear
1 3 12/10/2007 28 6.00 28.27 147,310 5,210 Shear
Average 5,240
1 4 01/07/2008 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KWIED) Page 1 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 305138
Project No.: 0712932
Date of Service: 11/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 11/12/2007
Weather Conditions: Cloudy, windy
Time Sampled: 04:10am Batch time: 03:53am
Temperature - Air: 620F Concrete: 740F
Truck No: 40 Ticket No: 9034
Air Content: 4.5% Unit Weight (pet): NA
Overall Placement Location:
Paving - southwest section of south parking lot, south side of building 7
Measured
Slump
(inches)
5.0
Sample Location:
175' east, 80' south from southwest corner of building 7
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
2 1 11/19/2007 7 6.00 28.27 112,230 3,970 Cone/Split
2 2 12/10/2007 28 6.00 28.27 144,950 5,130 Cone/Split
2 3 12/10/2007 28 6.00 28.27 150,840 5,330 Shear
Average 5,230
2 4 01/07/2008 56
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
{composition, appearance, etc.} or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
{KW/ED} Page 2 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, 8te 600, Houston, TX 77040
4421 Freidrich, 8te 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 305138
Project No.: 0712932
Date of Service: 11/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 11/12/2007
Weather Conditions: Cloudy, windy
Time Sampled: 05:25am Batch time: 05:09am
Temperature - Air: 610F Concrete: 760F
Truck No: 109 Ticket No: 9045
Air Content: 4.4% Unit Weight (pcf): NA
Overall Placement Location:
Paving _ southwest section of south parking lot, south side of building 7
Measured
Slump
(inches)
4.5
Sample Location:
230' east, 80' south from southwest corner of building 7
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
3 1 11/19/2007 7 6.00 28.27 109,240 3,860 Cone/Split
3 2 12/10/2007 28 6.00 28.27 141,360 5,000 Cone/Split
3 3 12/10/2007 28 6.00 28.27 147,250 5,210 Cone/Split
Average 5,100
3 4 01/07/2008 56
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KW/ED) Page 3 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 305138
Project No.: 0712932
Date of Service: 11/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753 PW
Placement Date: 11/12/2007
Weather Conditions: Cloudy, windy
Time Sampled: 06:40am Batch time: 06:19am
Temperature - Air: 640F Concrete: 760F
Truck No: 138 Ticket No: 9055
Air Content: 4.6% Unit Weight (pet): NA
Overall Placement Location:
Paving _ southwest section of south parking lot, south side of building 7
Measured
Slump
(inches)
5.0
Sample Location:
300' east, 70' south from southwest corner of building 7
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
4 1 11/19/2007 7 6.00 28.27 105,090 3,720 Cone/Split
4 2 12/10/2007 28 6.00 28.27 146,340 5,180 Shear
4 3 12/10/2007 28 6.00 28.27 138,910 4,910 Cone/Split
Average 5,040
4 4 01/07/2008 56
Remarks: Water added at site: 10 gallons
LIMITATION S: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KW/ED) Page 4 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 305138
Project No.: 0712932
Date of Service: 11/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753 PW
Placement Date: 11/12/2007
Weather Conditions: Cloudy, windy
Time Sampled: 07:45am Batch time: 07:33am
Temperature - Air: 69DF Concrete: 76DF
Truck No: 110 Ticket No: 9065
Air Content: 4.4% Unit Weight (pet): NA
Overall Placement Location:
Paving _ southwest section of south parking lot, south side of building 7
Measured
Slump
(inches)
5.5
Sample location:
380' east, 85' south from southwest corner of building 7
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
5 1 11/19/2007 7 6.00 28.27 100,000 3,540 Cone/Shear
5 2 12/10/2007 28 6.00 28.27 135,320 4,790 Cone/Shear
5 3 12/10/2007 28 6.00 28.27 139,510 4,930 Shear
Average 4,860
5 4 01/07/2008 56
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KW/ED) Page 5 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 305138
Project No.: 0712932
Date of Service: 11/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specificdtion Req uirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1 064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 11/12/2007
Weather Conditions: Cloudy, light rain
Time Sampled: 09:20am Batch time: 08:58am
Temperature - Air: 700F Concrete: 790F
Truck No: 138 Ticket No: 9075
Air Content: 4.5% Unit Weight (pct): NA
Overall Placement Location:
Paving _ southwest section of south parking lot, south side of building 7
Measured
Slump
(inches)
5.0
Sample Location:
425' east, 85' south from southwest corner of building 7
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
6 1 11/19/2007 7 6.00 28.27 95,550 3,380 Cone/Split
6 2 12/10/2007 28 6.00 28.27 131,930 4,670 Cone/Split
6 3 12/10/2007 28 6.00 28.27 131 ,560 4,650 Shear
Average 4,660
6 4 01/07/2008 56
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar SUbject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KW/ED) Page 6 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 305138
Project No.: 0712932
Date of Service: 11/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753 PW
Placement Date: 11/12/2007
Weather Conditions: Cloudy, windy
Time Sampled: 10:25am Batch time: 10:10am
Temperature - Air: 750F Concrete: 790F
Truck No: 138 Ticket No: 9085
Air Content: 4.6% Unit Weight (pet): NA
Overall Placement Location:
Paving _ southwest section of south parking lot, south side of building 7
Measured
Slump
(inches)
5.0
Sample Location:
480' east, 85' south from southwest corner of building 7
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
7 1 11/19/2007 7 6.00 28.27 89,640 3,170 Cone/Shear
7 2 12/10/2007 28 6.00 28.27 129,900 4,590 Cone/Split
7 3 12/10/2007 28 6.00 28.27 129,510 4,580 Shear
Average 4,590
7 4 01/07/2008 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KW/ED) Page 7 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 305138
Project No.: 0712932
Date of Service: 11/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 11/12/2007
Weather Conditions: Cloudy, windy
Time Sampled: 11 :20am Batch time:
Temperature - Air: 780F Concrete: 810F
Truck No: 130 Ticket No: 9095
Air Content: 4.6% Unit Weight (pct): NA
Overall Placement Location:
Paving _ southwest section of south parking lot, south side of building 7
Measured
Slump
(inches)
5.0
Sample Location:
530' east, 80' south from southwest corner of building 7
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
8 1 11/19/2007 7 6.00 28.27 95,410 3,370 Cone/Split
8 2 12/10/2007 28 6.00 28.27 137,640 4,870 Cone/Split
8 3 12/10/2007 28 6.00 28.27 136,360 4,820 Cone/Split
Average 4,850
8 4 01/07/2008 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KWfED) Page 8 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 305138
Project No.: 0712932
Date of Service: 11/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 11/12/2007
Weather Conditions: Partly cloudy, windy
Time Sampled: 12:15pm Batch time: 11:58am
Temperature - Air: 800F Concrete: 810F
Truck No: 130 Ticket No: 9103
Air Content: 4.5% Unit Weight (pet): NA
Overall Placement Location:
Paving - southwest section of south parking lot, south side of building 7
Measured
Slump
(inches)
5.0
Sample Location:
560' east, 75' south from southwest corner of building 7
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
9 1 11/19/2007 7 6.00 28.27 98,310 3,480 Shear
9 2 12/10/2007 28 6.00 28.27 150,270 5,310 Cone/Split
9 3 12/10/2007 28 6.00 28.27 132,900 4,700 Cone/Split
Average 5,010
9 4 01/07/2008 56
Finished:
013~;;;; ~
K. Scott Watson, AET
Project Manager
Technician: Pat Parks Started: 02:30am
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne
(1-ec copy)
1-cc Potter Concrete Attn: Mr Ryan Skelly
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KW/ED) Page 9 of 9
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little Yorl<, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 304067
Project No.: 0712932
Date of Service: 11/02/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Redi Mix
Plant: 136
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1 064
ASTM C-138
ASTM C-39
Mix Design 1.0.: L40N980A
Placement Date: 11/02/2007
Weather Conditions: Clear
Time Sampled: 04:45am
Temperature - Air: 450F
Truck No: 1039
Air Content: 5.5%
Overall Placement Location:
Lightweight concrete panels at Point West V11 - 1 st mix - panels P28, 44, 56, 59, 60,
61, 62, 63 - 380 yards
Batch time: 04: 15am
Concrete: 800F
Ticket No: 13600891
Unit Weight (pet): NA
Measured
Slump
(inches)
5.5
Sample Location:
P-44
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 11/09/2007 7 6.00 28.27 121,250 4,290 Shear
1 2 11/30/2007 28 6.00 28.27 159,300 5,630 Cone/Split
1 3 11/30/2007 28 6.00 28.27 163,720 5,790 Cone/Split
Average 5,710
1 4 12/28/2007 56
LIMIT A nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CHfED) Page 1 of 4
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 304067
Project No.: 0712932
Date of Service: 11/02/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Redi Mix
Plant: 136
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design I.D.: L40N980A
Placement Date: 11/02/2007
Weather Conditions: Clear
Time Sampled: 05:30am
Temperature - Air: 500F
Truck No: 1035
Air Content: 5.8%
Overall Placement Location:
Lightweight concrete panels at Point West V11 - 1 st mix - panels P28, 44, 56, 59, 60,
61, 62, 63 - 380 yards
Batch time: 04:57am
Concrete: 800F
Ticket No: 13600898
Unit Weight (pet): NA
Measured
Slump
(inches)
5.25
Sample Location:
P-59
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
2 1 11/09/2007 7 6.00 28.27 121,390 4,290 Cone/Split
2 2 11/30/2007 28 6.00 28.27 170,450 6,030 Cone/Split
2 3 11/30/2007 28 6.00 28.27 167,380 5,920 Shear
Average 5,970
2 4 12/28/2007 56
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar SUbject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 2 of 4
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 304067
Project No.: 0712932
Date of Service: 11/02/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Redi Mix
Plant: 136
Specification Req uirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: L40N980A
Placement Date: 11/02/2007
Weather Conditions: Sunny, clear
Time Sampled: 08:30am Batch time: 07:59am
Temperature - Air: 550F Concrete: 840F
Truck No: 1190 Ticket No: 13600926
Air Content: 5.1 % Unit Weight (pet): NA
Overall Placement Location:
Lightweight concrete panels at Point West V11 - 1 st mix - panels P28, 44, 56, 59, 60,
61,62,63 - 380 yards
Measured
Slump
(inches)
5.0
Sample Location:
P-63
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
3 1 11/09/2007 7 6.00 28.27 147,100 5,200 Cone/Split
3 2 11/30/2007 28 6.00 28.27 182,410 6,450 Shear
3 3 11/30/2007 28 6.00 28.27 198,130 7,010 Cone/Split
Average 6,730
3 4 12/28/2007 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 3 of 4
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304067
Project No.: 0712932
Date of Service: 11/02/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Redi Mix
Plant: 136
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
5.25
Mix Design I.D.: L40N980A
Placement Date: 11/02/2007
Weather Conditions: Sunny, partly cloudy
Time Sampled: 10:40am Batch time: 09:51am
Temperature - Air: 600F Concrete: 860F
Truck No: 1187 Ticket No: 13600943
Air Content: 5.8% Unit Weight (pet): NA
Overall Placement Location:
Lightweight concrete panels at Point West V11 - 1 st mix - panels P28, 44, 56, 59, 60,
61, 62, 63 - 380 yards
Sample Location:
P-61
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
4 1 11/09/2007 7 6.00 28.27 107,350 3,800 Shear
4 2 11/30/2007 28 6.00 28.27 151,070 5,340 Cone/Split
4 3 11/30/2007 28 6,00 28.27 135,630 4,800 Cone/Split
Average 5,070
4 4 12/28/2007 56
Technician: Montreal Bailey Rone Engineering
See Report 304066 for technician time~ ~
Report Distribution: . ~
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne .. .. . . . .
(1-ec copy) . .-
1-cc P?tter Concrete Attn: Mr Ryan Skelly K. Scott Watson AET
1-cc City of Coppell Attn: Mr. Lee Stone p 'eel M '
1-cc City of Coppell Attn: Mr. Larry Davis rOJ anager
~
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 4 of 4
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301764
Project No.: 0712932
Date of Service: 10/11/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 3,000 psi @ 28 days
Slump (in.): NA
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7751 PW
Placement Date: 10/11/2007
Weather Conditions: Clear
Time Sampled: 09:10am
Temperature - Air: 720F
Truck No: 139
Air Content: NA
Overall Placement Location:
Building piers
Batch time: 08:24am
Concrete: 810F
Ticket No: 14682
Unit Weight (pet): NA
Measured
Slump
(inches)
7.0
Sample Location:
Pier G.8/30
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (inZ) (Ibs) (psi) Type
1 1 10/18/2007 7 6.00 28.27 99,060 3,500 Shear
1 2 10/18/2007 7 6.00 28.27 94,960 3,360 Shear
Average 3,430
1 3 11/08/2007 28 6.00 28.27 131,640 4,660 Cone/Split
1 4 11/08/2007 28 6.00 28.27 127,860 4,520 Cone/Split
Average 4,590
1 5 12/06/2007 56 6.00 28.27 143,420 5,070 Cone/Split
Technician: Chris Harbour Rone Engineering
See Report 301763 for technician time~ ~
Report Distribution: . .. ~~
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne . .. - - -- - ~
(1-eccopy) - - -
1-cc p~tter Concrete Attn: Mr Ryan Skelly K. Scott Watson AET
1-cc City of Coppell Attn: Mr. Lee Stone P . t M '
1-cc City of Coppell Attn: Mr. Larry Davis rOJec anager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the dients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/ED) Page 1 of 1
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304300
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Redi-Mix
Plant: P136
Specification Req uirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 340K1501
Placement Date: 11/05/2007
Weather Conditions: Clear
Time Sampled: 05:13am
Temperature - Air: 630F
Truck No: 1188
Air Content: NA
Overall Placement Location:
Tilt wall panels 77-87
Batch time: 04:55am
Concrete: 810F
Ticket No: 13601009
Unit Weight (pet): NA
Measured
Slump
(inches)
5.5
Sample Location:
Southwest corner of tilt wall panel 80
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 11/12/2007 7 6.00 28.27 97,900 3,460 Cone/Split
1 2 12/03/2007 28 6.00 28.27 129,480 4,580 Cone/Split
1 3 12/03/2007 28 6.00 28.27 124,120 4,390 Cone/Split
Average 4,480
1 4 12/31/2007 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/ED) Page 1 of 3
Rone Eni==
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304300
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations. perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Redi-Mix
Plant: P136
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 340K1501
Placement Date: 11/05/2007
Weather Conditions: Clear
Time Sampled: 06:04am
Temperature - Air: 630F
Truck No: 1188
Air Content: NA
Overall Placement Location:
Tilt wall panels 77-87
Batch time: 05:35am
Concrete: 790F
Ticket No: 13601021
Unit Weight (pet): NA
Measured
Slump
(inches)
5.0
Sample Location:
Northwest comer of tilt wall panel 82
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
2 1 11/08/2007 3 6.00 28.27 78,870 2,790 Shear
2 2 11/12/2007 7 6.00 28.27 102,290 3,620 Shear
2 3 12/03/2007 28 6.00 28.27 124,100 4,390 Cone/Shear
2 4 12/03/2007 28 6.00 28.27 131,580 4,650 Shear
Average 4,520
2 5 12/31/2007 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/ED) Page 2 of 3
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, 8te 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304300
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Redi-Mix
Plant: P136
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 340K1501
Placement Date: 11/05/2007
Weather Conditions: Clear
Time Sampled: 06:59am
Temperature - Air: 630F
Truck No: 1188
Air Content: NA
Overall Placement Location:
Tilt wall panels 77-87
Batch time: 06:29am
Concrete: 820F
Ticket No: 13601032
Unit Weight (pet): NA
Measured
Slump
(inches)
5.5
Sample Location:
Northwest corner of tilt wall panel 85
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (inZ) (Ibs) (psi) Type
3 1 11/08/2007 3 6.00 28.27 81,970 2,900 Shear
3 2 11/12/2007 7 6.00 28.27 105,590 3,730 Cone/Split
3 3 12/03/2007 28 6.00 28.27 133,510 4,720 Shear
3 4 12/03/2007 28 6.00 28.27 127,900 4,520 Shear
Average 4,620
3 5 12/31/2007 56
Finished: 08:45am R E
~2~
Technician: Clayton Snyder Started: 04: 15am
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne
(1-ec copy)
1-cc Potter Concrete Attn: Mr. Ryan Skelly
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMIED) Page 3 of 3
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 304066
Project No.: 0712932
Date of Service: 11/02/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 9349 PW
Placement Date: 11/02/2007
Weather Conditions: Sunny, clear
Time Sampled: 11 :35am Batch time: 11 :22am
Temperature - Air: 700F Concrete: 900F
Truck No: 144 Ticket No: 8741
Air Content: 4.0% Unit Weight (pet): NA
Overall Placement Location:
Panels at Point West VII _ 2nd mix 340 yards - panels 64,65, 66, 67, 68, 69, 70, 71,
72, 73, 74, 75, 76
Measured
Slump
(inches)
5.75
Sample Location:
P-64
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 11/09/2007 7 6.00 28.27 104,710 3,700 Cone/Split
1 2 11/30/2007 28 6.00 28.27 141 ,740 5,010 Shear
1 3 11/30/2007 28 6.00 28.27 135,420 4,790 Cone/Split
Average 4,900
1 4 12/28/2007 56
Remarks: Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CHIED) Page 1 of 4
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 304066
Project No.: 0712932
Date of Service: 11/02/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design I.D.: 9349 PW
Placement Date: 11/02/2007
Weather Conditions: Sunny, clear
Time Samplerl: 12:45pm Batch time: 12:31am
Temperature - Air: 700F Concrete: 900F
Truck No: 106 Ticket No: 8749
Air Content: 4.3% Unit Weight (pcf): NA
Overall Placement Location:
Panels at Point West VII - 2nd mix 340 yards - panels 64, 65, 66, 67, 68, 69, 70, 71,
72, 73, 74, 75, 76
Measured
Slump
(inches)
5.5
Sample Location:
P-67
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
2 1 11/09/2007 7 6.00 28.27 106,050 3,750 Cone/Split
2 2 11/30/2007 28 6.00 28.27 143,710 5,080 Cone/Split .
2 3 11/30/2007 28 6.00 28.27 148,260 5,240 Cone/Split
Average 5,160
2 4 12/28/2007 56
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 2 of 4
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 304066
Project No.: 0712932
Date of Service: 11/02/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 9349 PW
Placement Date: 11/02/2007
Weather Conditions: Sunny, clear
Time Sampled: 02:00pm Batch time: 01 :42pm
Temperature - Air: 720F Concrete: 900F
Truck No: 120 Ticket No: 8759
Air Content: 4.6% Unit Weight (pet): NA
Overall Placement Location:
Panels at Point West VII _ 2nd mix 340 yards - panels 64,65,66,67,68,69,70, 71,
72, 73, 74, 75, 76
Measured
Slump
(inches)
5.75
Sample Location:
P-71
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
3 1 11/09/2007 7 6.00 28.27 118,510 4,190 Cone/Split
3 2 11/30/2007 28 6.00 28.27 152,490 5,390 Shear
3 3 11/30/2007 28 6.00 28.27 150,860 5,340 Shear
Average 5,360
3 4 12/28/2007 56
Remarks: Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar SUbject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CHIED) Page 3 of 4
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 304066
Project No.: 0712932
Date of Service: 11/02/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 9349 PW
Placement Date: 11/02/2007
Weather Conditions: Sunny, clear
Time Sampled: 03:00pm Batch time: 02:46pm
Temperature - Air: 750F Concrete: 910F
Truck No: 106 Ticket No: 8768
Air Content: 4.4% Unit Weight (pet): NA
Overall Placement Location:
Panels at Point West VII - 2nd mix 340 yards - panels 64, 65, 66, 67, 68, 69, 70, 71,
72, 73, 74, 75, 76
Measured
Slump
(inches)
5.75
Sample Location:
P-76
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
4 1 11/09/2007 7 6.00 28.27 114,690 4,060 Cone/Split
4 2 11/30/2007 28 6.00 28.27 159,690 5,650 Shear
4 3 11/30/2007 28 6.00 28.27 160,780 5,690 Cone/Split
Average 5,670
4 4 12/28/2007 56
Remarks: Water added at site: 10 gallons
Technician: Montreal Bailey Started: 02:30am
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne
(1-ec copy)
1-cc Potter Concrete Attn: Mr Ryan Skelly
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
Finished:
~w~;;;;;, ~
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results preSented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services. Ltd.
(CH/ED) Page 4 of 4
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301953
Project No.: 0712932
Date of Service: 10/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 10/12/2007
Weather Conditions: Cloudy
Time Sampled: 03:14am
Temperature - Air: 600F
Truck No: 142
Air Content: 4.5%
Overall Placement Location:
Northwest side corner of building
Batch time: 02:40am
Concrete: 800F
Ticket No: 14739
Unit Weight (pcf): NA
Measured
Slump
(inches)
5.0
Sample Location:
15' west, 5' north from northwest corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 10/19/2007 7 6.00 28.27 137,650 4,870 Shear
1 2 11/09/2007 28 6.00 28.27 173,370 6,130 Cone/Split
1 3 11/09/2007 28 6.00 28.27 171,980 6,080 Cone/Split
Average 6,110
1 4 12/07/2007 56 6.00 28.27 182,730 6,460 Cone/Split
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 1 of 10
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301953
Project No.: 0712932
Date of Service: 10/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 10/12/2007
Weather Conditions: Cloudy
Time Sampled: 04:51am
Temperature - Air: 600F
Truck No: 125
Air Content: 4.5%
Overall Placement Location:
Northwest side corner of building
Batch time: 04:24am
Concrete: 830F
Ticket No: 14749
Unit Weight (pet): NA
Measured
Slump
(inches)
5.5
Sample Location:
25' north, 20' west from northwest corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
2 1 10/19/2007 7 6.00 28.27 129,870 4,590 Cone/Split
2 2 11/09/2007 28 6.00 28.27 164,830 5,830 Cone/Split
2 3 11/09/2007 28 6.00 28.27 161,720 5,720 Cone/Split
Average 5,770
2 4 12/07/2007 56 6.00 28.27 184,290 6,520 Cone/Shear
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 2 of 10
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301953
Project No.: 0712932
Date of Service: 10/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753 PW
Placement Date: 10/12/2007
Weather Conditions: Cloudy
Time Sampled: 06:20am
Temperature - Air: 850F
Truck No: 117
Air Content: 5.5%
Overall Placement Location:
Northwest side corner of building
Batch time: 05:56am
Concrete: 620F
Ticket No: 14762
Unit Weight (pet): NA
Measured
Slump
(inches)
4.5
Sample Location:
30' north, 20' east from northeast corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
3 1 10/19/2007 7 6.00 28.27 124,720 4,410 Shear
3 2 11/09/2007 28 6.00 28.27 152,310 5,390 Shear
3 3 11/09/2007 28 6.00 28.27 141 , 150 4,990 Cone/Split
Average 5,190
3 4 12/07/2007 56 6.00 28.27 163,010 5,770 Cone/Split
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition. appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services. Ltd.
(CH/ED) Page 3 of 10
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301953
Project No.: 0712932
Date of Service: 10/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Req uirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 10/12/2007
Weather Conditions: Sunny
Time Sampled: 07:38am
Temperature. Air: 610F
Truck No: 148
Air Content: 4.5%
Overall Placement Location:
Northwest side corner of building
Batch time: 07:00am
Concrete: 850F
Ticket No: 14769
Unit Weight (pct): NA
Measured
Slump
(inches)
5.0
Sample Location:
40' north, 25' east from northeast corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
4 1 10/19/2007 7 6.00 28.27 95,490 3,380 Cone/Split
4 2 11/09/2007 28 6.00 28.27 127,220 4,500 Cone/Split
4 3 11/09/2007 28 6.00 28.27 125,390 4,430 Cone/Split
Average 4,470
4 4 12/07/2007 56 6.00 28.27 143,270 5,070 Shear
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CHIED) Page 4 of 10
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W LitUe York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630.9745
Report of Concrete Compressive Strength Test
Report No.: 301953
Project No.: 0712932
Date of Service: 10/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753 PW
Placement Date: 10/12/2007
Weather Conditions: Sunny
Time Sampled: 09:03am
Temperature - Air: 650F
Truck No: 110
Air Content: 3.5%
Overall Placement Location:
Northwest side corner of building
Batch time: 08: 19am
Concrete: 850F
Ticket No: 14781
Unit Weight (pcf): NA
Measured
Slump
(inches)
5.0
Sample Location:
45' north, 36' west from northwest corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
5 1 10/19/2007 7 6.00 28.27 104,410 3,690 Cone/Split
5 2 11/09/2007 28 6.00 28.27 134,240 4,750 Shear
5 3 11/09/2007 28 6.00 28.27 129,660 4,590 Cone/Split
Average 4,670
5 4 12/07/2007 56 6.00 28.27 140,770 4,980 Cone/Split
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 5 of 10
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301953
Project No.: 0712932
Date of Service: 10/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 10/12/2007
Weather Conditions: Sunny
Time Sampled: 10:30am
Temperature - Air: 700F
Truck No: 104
Air Content: 4.5%
Overall Placement Location:
Northwest side corner of building
Batch time: 09:05am
Concrete: 900F
Ticket No: 14790
Unit Weight (pcf): NA
Measured
Slump
(inches)
5.0
Sample Location:
50' north, 15' west from northwest corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
6 1 10/19/2007 7 6.00 28.27 88,290 3,120 Shear
6 2 11/09/2007 28 6.00 28.27 123,980 4,380 Cone/Split
6 3 11/09/2007 28 6.00 28.27 127,670 4,520 Shear
Average 4,450
6 4 12/07/2007 56 6.00 28.27 139,310 4,930 Shear
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 6 of 10
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301953
Project No.: 0712932
Date of Service: 10/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 10/12/2007
Weather Conditions: Sunny
Time Sampled: 11 :26am
Temperature. Air: 700F
Truck No: 110
Air Content: 4.5%
Overall Placement Location:
Northwest side corner of building
Batch time: 10:39am
Concrete: 900F
Ticket No: 7948
Unit Weight (pcf): NA
Measured
Slump
(inches)
4.5
Sample Location:
60' north, 10' east from northeast corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
7 1 10/19/2007 7 6.00 28.27 94,980 3,360 Shear
7 2 11/09/2007 28 6.00 28.27 120,770 4,270 Shear
7 3 11/09/2007 28 6.00 28.27 132,120 4,670 Shear
Average 4,470
7 4 12/07/2007 56 6.00 28.27 142,550 5,040 Cone/Split
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 7 of 10
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301953
Project No.: 0712932
Date of Service: 10/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 10/12/2007
Weather Conditions: Sunny
Time Sampled: 12:15pm
Temperature - Air: 760F
Truck No: 110
Air Content: 3.5%
Overall Placement Location:
Northwest side corner of building
Batch time: 11: 19am
Concrete: 900F
Ticket No: 14804
Unit Weight (pet): NA
Measured
Slump
(inches)
5.0
Sample Location:
70' north, 20' west from northwest corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
8 1 10/19/2007 7 6.00 28.27 107,740 3,810 Shear
8 2 11/09/2007 28 6.00 28.27 145,280 5,140 Cone/Split
8 3 11/09/2007 28 6.00 28.27 142,710 5,050 Cone/Split
Average 5,090
8 4 12/07/2007 56 6.00 28.27 151,890 5,370 Shear
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 8 of 10
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301953
Project No.: 0712932
Date of Service: 10/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Req uirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 10/12/2007
Weather Conditions: Sunny
Time Sampled: 01 :55pm
Temperature - Air: 900F
Truck No: 142
Air Content: 5.5%
Overall Placement Location:
Northwest side corner of building
Batch time: 01:14pm
Concrete: 750F
Ticket No: 14818
Unit Weight (pcf): NA
Measured
Slump
(inches)
4.5
Sample Location:
25' south, 15' west from southwest corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
9 1 10/19/2007 7 6.00 28.27 104,340 3,690 Cone/Split
9 2 11/09/2007 28 6.00 28.27 132,590 4,690 Cone/Split
9 3 11/09/2007 28 6.00 28.27 136,910 4,840 Cone/Shear
Average 4,770
9 4 12/07/2007 56 6.00 28.27 139,430 4,930 Cone/Split
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 9 of 10
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7101 W Little York, Ste 600, Houston, TX 71040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301953
Project No.: 0712932
Date of Service: 10/12/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 01
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 5" maximum
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design J.D.: 7753 PW
Placement Date: 10/12/2007
Weather Conditions: Sunny
Time Sampled: 02:50am
Temperature - Air: 780F
Truck No: 117
Air Content: 3.5%
Overal1 Placement Location:
Northwest side corner of building
Batch time: 01 :58pm
Concrete: 900F
Ticket No: 14828
Unit Weight (pet): NA
Measured
Slump
(inches)
4.5
Sample Location:
25' south, 20' east from southeast corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
10 1 10/19/2007 7 6.00 28.27 100,750 3,560 Cone/Split
10 2 11/09/2007 28 6.00 28.27 143,270 5,070 Cone/Split
10 3 11/09/2007 28 6.00 28.27 135,540 4,790 Cone/Split
Average 4,930
10 4 12/07/2007 56 6.00 28.27 153,040 5,410 Cone/Split
Technician: Jimmy Scott Started: 02:00am
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne
(1-ec copy)
1-cc Potter Concrete Attn: Mr Ryan Skelly
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
flnlsh~' 03~~;;;l ~
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engi01eering Services, Ltd.
(CHfED) Page 10 of 10
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 302451
Project No.: 0712932
Date of Service: 10/19/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: On Site
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4.0" - 6.0"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design J.D.: 9349PW
Placement Date: 10/19/2007
Weather Conditions: Clear
Time Sampled: 04:17am
Temperature - Air: 560F
Truck No: 140
Air Content: 1.2%
Overall Placement Location:
Tilt wall panels: P89-P97, P99-P106, P115-P119, P121-P123
Batch time:
Concrete: 690F
Ticket No: NA
Unit Weight (pet): NA
Measured
Slump
(inches)
6.5
Sample Location:
P90, Middle section
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 10/26/2007 7 6.00 28.27 115,620 4,090 Shear
1 2 11/02/2007 14 6.00 28.27 128,050 4,530 Shear
1 3 11/16/2007 28 6.00 28.27 153,890 5,440 Cone/Split
1 4 11/16/2007 28 6.00 28.27 159,830 5,650 Cone/Shear
Average 5,550
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/ED) Page 1 of 6
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 302451
Project No.: 0712932
Date of Service: 10/19/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perfonm required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Measured
Slump
(inches)
5.0
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: On Site
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4.0" - 6.0"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 9349PW
Placement Date: 10/19/2007
Weather Conditions: Clear
Time Sampled: 05:37am
Temperature - Air: 510F
Truck No: 138
Air Content: 1.1 %
Overall Placement Location:
Tilt wall panelS: P89-P97, P99-P106, P115-P119, P121-P123
Batch time:
Concrete: 750F
Ticket No: NA
Unit Weight (pet): NA
Sample Location:
P96, Top section
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
2 1 10/26/2007 7 6.00 28.27 123,260 4,360 Shear
2 2 11/02/2007 14 6.00 28.27 139,450 4,930 Cone/Split
2 3 11/16/2007 28 6.00 28.27 163,820 5,790 Cone/Split
2 4 11/16/2007 28 6.00 28.27 141 , 160 4,990 Shear
Average 5,390
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar SUbject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/ED) Page 2 of 6
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 302451
Project No.: 0712932
Date of Service: 10/19/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: On Site
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4.0" - 6.0"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9349PW
Placement Date: 10/19/2007
Weather Conditions: Clear / Windy
Time Sampled: 07:45am Batch time:
Temperature - Air: 520F Concrete: 740F
Truck No: 109 Ticket No: NA
Air Content: 1.3% Unit Weight (pcf): NA
Overall Placement Location:
Tilt wall panels: P89-P97, P99-P106, P115-P119, P121-P123
Measured
Slump
(inches)
4.75
Sample Location:
P104, Bottom section
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
3 1 10/26/2007 7 6.00 28.27 102,460 3,620 Cone/Split
3 2 11/02/2007 14 6.00 28.27 113,960 4,030 Cone/Split
3 3 11/16/2007 28 6.00 28.27 136,930 4,840 Cone/Split
3 4 11/16/2007 28 6.00 28.27 137,290 4,860 Cone/Split
Average 4,850
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/ED) Page 3 of 6
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 302451
Project No.: 0712932
Date of Service: 10/19/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: On Site
Specification Req uirements
Strength: 4,000 psi @28 days
Slump (in.): 4.0" - 6.0"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9349PW
Placement Date: 10/19/2007
Weather Conditions: Clear / Windy
Time Sampled: 09:25am Batch time:
Temperature - Air: 630F Concrete: 750F
Truck No: 132 Ticket No: NA
Air Content: 1.2% Unit Weight (pct): NA
Overall Placement Location:
Tilt wall panels: P89-P97, P99-P106, P115-P119, P121-P123
Measured
Slump
(inches)
4.5
Sample Location:
P116, Middle section
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
4 1 10/26/2007 7 6.00 28.27 114,020 4,030 Cone/Split
4 2 11/02/2007 14 6.00 28.27 129,730 4,590 Cone/Split
4 3 11/16/2007 28 6.00 28.27 156,790 5,550 Cone/Split
4 4 11/16/2007 28 6.00 28.27 150,310 5,320 Cone/Split
Average 5,430
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exdusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, LId.
(LB/ED) Page 4 of 6
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 302451
Project No.: 0712932
Date of Service: 10/19/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: On Site
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4.0" - 6.0"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design I.D.: 9349PW
Placement Date: 10/19/2007
Weather Conditions: Clear
Time Sampled: 11 :03am
Temperature - Air: 730F
Truck No: 107
Air Content: 1.1 %
Overall Placement Location:
Tilt wall panels: P89-P97, P99-P106, P115-P119, P121-P123
Batch time:
Concrete: 750F
Ticket No: NA
Unit Weight (pet): NA
Measured
Slump
(inches)
5.0
Sample Location:
P121, Top section
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
5 1 10/26/2007 7 6.00 28.27 110,710 3,920 Shear
5 2 11/02/2007 14 6.00 28.27 127,530 4,510 Cone/Split
5 3 11/16/2007 28 6.00 28.27 151,290 5,350 Cone/Split
5 4 11/16/2007 28 6.00 28.27 145,160 5,130 Cone/Split
Average 5,240
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/ED) Page 5 of 6
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 302451
Project No.: 0712932
Date of Service: 10/19/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: On Site
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4.0" - 6.0"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 9349PW
Placement Date: 10/19/2007
Weather Conditions: Clear
Time Sampled: 02:15am
Temperature - Air: 750F
Truck No: 140
Air Content: 1.2%
Overall Placement Location:
Tilt wall panels: P89-P97, P99-P106, P115-P119, P121-P123
Batch time:
Concrete: 750F
Ticket No: NA
Unit Weight (pct): NA
Measured
Slump
(inches)
4.75
Sample Location:
P123, Top section
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
6 1 10/26/2007 7 6.00 28.27 93,650 3,310 Shear
6 2 11/02/2007 14 6.00 28.27 111 ,950 3,960 Cone/Split
6 3 11/16/2007 28 6.00 28.27 135,040 4,780 Cone/Split
6 4 11/16/2007 28 6.00 28.27 130,940 4,630 Shear
Average 4,700
Technician: Javier Martinez Started: 03:15am
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne
(1-ec copy)
1-cc Potter Concrete Attn: Mr Ryan Skelly
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
Finished:
021~;;d .~
K. Scot! Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(LB/ED) Page 6 of 6
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214)630-9745
Report of Concrete Compressive Strength Test
Report No.: 302575
Project No.: 0712932
Date of Service: 10/20/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: On site
Specification Req uirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 9349
Placement Date: 10/20/2007
Weather Conditions: Clear, windy
Time Sampled: 04:45am Batch time:
Temperature - Air: 580F Concrete: 670F
Truck No: 110 Ticket No:
Air Content: 1.2% Unit Weight (pcf): NA
Overall Placement Location:
Tilt wall panels, P124-P128, P131-P146
Measured
Slump
(inches)
5.0
Sample Location:
P128, top section
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 10/27/2007 7 6.00 28.27 111,910 3,960 Cone/Split
1 2 11/03/2007 14 6.00 28.27 133,780 4,730 Shear
1 3 11/17/2007 28 6.00 28.27 154,710 5,470 Cone/Split
1 4 11/17/2007 28 6.00 28.27 145,820 5,160 Cone/Shear
Average 5,310
LIMIT A nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMIED) Page 1 of 4
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 302575
Project No.: 0712932
Date of Service: 10/20/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: On site
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 9349
Placement Date: 10/20/2007
Weather Conditions: Clear, windy
Time Sampled: 07:15am Batch time:
Temperature - Air: 570F Concrete: 700F
Truck No: 131 Ticket No:
Air Content: 1.3% Unit Weight (pcf): NA
Overall Placement Location:
Tilt wall panels, P124-P128, P131-P146
Measured
Slump
(inches)
6.0
Sample Location:
P131, middle section
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
2 1 10/27/2007 7 6.00 28.27 99,830 3,530 Shear
2 2 11/03/2007 14 6.00 28.27 118,190 4,180 Shear
2 3 11/17/2007 28 6.00 28.27 146,850 5,190 Cone/Shear
2 4 11/17/2007 28 6.00 28.27 148,120 5,240 Cone/Split
Average 5,220
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/ED) Page 2 of 4
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 302575
Project No.: 0712932
Date of Service: 10/20/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: On site
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 9349
Placement Date: 10/20/2007
Weather Conditions: Clear, windy
Time Sampled: 09:15am Batch time:
Temperature - Air: 680F Concrete: 700F
Truck No: 110 Ticket No:
Air Content: 1.3% Unit Weight (pct): NA
Overall Placement Location:
Tilt wall panels, P124-P128, P131-P146
Measured
Slump
(inches)
5.5
Sample Location:
P145
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
3 1 10/27/2007 7 6.00 28.27 102,730 3,630 Shear
3 2 11/03/2007 14 6.00 28.27 119,150 4,210 Shear
3 3 11/17/2007 28 6.00 28.27 157,720 5,580 Cone/Split
3 4 11/17/2007 28 6.00 28.27 151,750 5,370 Cone/Split
Average 5,470
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMIED) Page 3 of 4
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 302575
Project No.: 0712932
Date of Service: 10/20/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: On site
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): NA
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 9349
Placement Date: 10/20/2007
Weather Conditions: Clear, windy
Time Sampled: 10:15am Batch time:
Temperature - Air: 710F Concrete: 750F
Truck No: 110 Ticket No:
Air Content: 1.1 % Unit Weight (pct): NA
Overall Placement Location:
Tilt wall panels, P124-P128, P131-P146
Measured
Slump
(inches)
6.0
Sample Location:
P143, top section
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
4 1 10/27/2007 7 6.00 28.27 104,250 3,690 Cone/Split
4 2 11/03/2007 14 6.00 28.27 123,640 4,370 Shear
4 3 11/17/2007 28 6.00 28.27 145,222 5,140 Cone/Shear
4 4 11/17/2007 28 6.00 28.27 152,850 5,410 Cone/Shear
Average 5,270
Technician: Javier Martinez Started: 04:00am
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne
(1-ec copy)
1-cc Potter Concrete Attn: Mr Ryan Skelly
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
Finished:
11 : 15am R E .
~;a~
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar SUbject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM!ED) Page 4 of 4
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Batch time: 02:57am
Concrete: 820F
Ticket No: 8772
Unit Weight (pet): NA
Measured
Slump
(inches)
4.0
Mix Design I.D.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Clear
Time Sampled: 03:10am
Temperature - Air: 550F
Truck No: 140
Air Content: 4.1 %
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Sample Location:
50' north, 15' west from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 11/12/2007 7 6.00 28.27 128,750 4,550 Cone/Split
1 2 12/03/2007 28 6.00 28.27 169,460 5,990 Cone/Split
1 3 12/03/2007 28 6.00 28.27 163,120 5,770 Shear
Average 5,880
1 4 12/31/2007 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KW/KW) Page 1 of 9
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable.standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Clear
Time Sampled: 04: 15am
Temperature - Air: 550F
Truck No: 109
Air Content: 1.3%
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Batch time: 04:00am
Concrete: 820F
Ticket No: 8779
Unit Weight (pcf): NA
Measured
Slump
(inches)
4.25
Sample Location:
75' north, 10' east from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
2 1 11/12/2007 7 6.00 28.27 115,670 4,090 Cone/Split
2 2 12/03/2007 28 6.00 28.27 149,660 5,290 Cone/Shear
2 3 12/03/2007 28 6.00 28.27 156,090 5,520 Cone/Split
Average 5,410
2 4 12/31/2007 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KW/KW) Page 2 of 9
Rone Engineering
.
8908 Ambassatlor Row, Dallas, TX 75247
7701 W Little York, 8te 600, Houston, TX 77040
4421 Freitlrich, 8te 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design I.D.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Clear
Time Sampled: 05:40am
Temperature - Air: 580F
Truck No: 101
Air Content: 4.8%
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Batch time: 05:14am
Concrete: 820F
Ticket No: 8792
Unit Weight (pcf): NA
Measured
Slump
(inches)
5.5
Sample Location:
40' north, 25' east from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
3 1 11/12/2007 7 6.00 28.27 86,650 3,060 Cone/Split
3 2 12/03/2007 28 6.00 28.27 110,840 3,920 Cone/Split
3 3 12/03/2007 28 6.00 28.27 110,360 3,900 Cone/Split
Average 3,910 *
3 4 12/31/2007 56
* Does not comply with specified strength
Remarks: Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exdusive use of the dients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KW/KW) Page 3 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
n01 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Sunny, clear
Time Sampled: 06:50am Batch time: 06:34am
Temperature - Air: 600F Concrete: 850F
Truck No: 130 Ticket No: 8803
Air Content: 4.5% Unit Weight (pet): NA
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Measured
Slump
(inches)
5.75
Sample Location:
15' north, 50' east from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
4 1 11/12/2007 7 6.00 28.27 83,520 2,950 Cone/Shear
4 2 12/03/2007 28 6.00 28.27 107,880 3,820 Shear
4 3 12/03/2007 28 6.00 28.27 110,380 3,900 Cone/Split
Average 3,860 *
4 4 12/31/2007 56
* Does not comply with specified strength
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KW/KW) Page 4 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Sunny, clear
Time Sampled: 07:45am Batch time: 07:25am
Temperature - Air: 600F Concrete: 850F
Truck No: 101 Ticket No: 8810
Air Content: 4.6% Unit Weight (pet): NA
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Measured
Slump
(inches)
5.0
Sample Location:
40' east from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
5 1 11/12/2007 7 6.00 28.27 120,990 4,280 Cone/Split
5 2 12/03/2007 28 6.00 28.27 134,620 4,760 Shear
5 3 12/03/2007 28 6.00 28.27 135,730 4,800 Shear
Average 4,780
5 4 12/31/2007 56
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KW/KW) Page 5 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Sunny, clear
Time Sampled: 10:30am Batch time: 10:08am
Temperature. Air: 700F Concrete: 900F
Truck No: 138 Ticket No: 8823
Air Content: 4.6% Unit Weight (pet): NA
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Measured
Slump
(inches)
4.75
Sample Location:
50' east, 25' south from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
6 1 11/12/2007 7 6.00 28.27 79,360 2,810 Cone/Split
6 2 12/03/2007 28 6.00 28.27 110,030 3,890 Cone/Split
6 3 12/03/2007 28 6.00 28.27 117,980 4,170 Cone/Shear
Average 4,030
6 4 12/31/2007 56
Remarks: Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KW/KW) Page 6 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Sunny, clear
Time Sampled: 11 :55am Batch time: 11 :35am
Temperature - Air: 750F Concrete: 900F
Truck No: 140 Ticket No: 8838
Air Content: 1.5% Unit Weight (pet): NA
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lanefapproach
Measured
Slump
(inches)
4.0
Sample Location:
30' east, 90' south from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
7 1 11/12/2007 7 6.00 28.27 109,080 3,860 Cone/Split
7 2 12/03/2007 28 6.00 28.27 133,600 4,730 Shear
7 3 12/03/2007 28 6.00 28.27 130,610 4,620 Cone/Split
Average 4,670
7 4 12/31/2007 56
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KW/KW) Page 7 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM'C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Sunny, clear
Time Sampled: 01:45pm Batch time: 01:16pm
Temperature - Air: 800F Concrete: 920F
Truck No: 126 Ticket No: 15677
Air Content: 4.9% Unit Weight (pet): NA
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Measured
Slump
(inches)
4.5
Sample Location:
45' east, 140' south from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
8 1 11/12/2007 7 6.00 28.27 106,910 3,780 Cone/Split
8 2 12/03/2007 28 6.00 28.27 132,390 4,680 Cone/Shear
8 3 12/03/2007 28 6.00 28.27 115,420 4,080 Shear
Average 4,380
8 4 12/31/2007 56
LIMITATION S: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in fuli without the written approval of Rone Engineering Services, Ltd.
(KW/KW) Page 8 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 12/11/2007
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Sunny, clear
Time Sampled: 03:00pm Batch time: 02:32pm
Temperature - Air: 820F Concrete: 920F
Truck No: 130 Ticket No: 8852
Air Content: 4.5% Unit Weight (pet): NA
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking aAd east fire
lane/approach
Measured
Slump
(inches)
6.5
Sample Location:
50' east, 200' south from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
9 1 11/12/2007 7 6.00 28.27 78,900 2,790 Cone/Split
9 2 12/03/2007 28 6.00 28.27 124,380 4,400 Shear
9 3 12/03/2007 28 6.00 28.27 121,940 4,310 Cone/Split
Average 4,360
9 4 12/31/2007 56
Started: 02:00am Finished: 04:00pm
Technician: Montreal Bailey
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne
(1-ec copy)
1-cc Potter Concrete Attn: Mr Ryan Skelly
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
Rone Engineering
p~~
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(KW/KW) Page 9 of 9