Duke Lesley 3C-LR080116
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
n01 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Reinforcing Steel Inspection
Report No.: 310562
Project No.: 0711530
Date of Service: 01/12/2008
Report Date: 01/16/2008
Project: Point West Office I
Services: Reinforcing Steel Inspection
Report of Inspection
Locations and Items Inspected:
Slab on level 1 by elevators, grid lines 9-11/C.O-L.O
Items Inspected: Conforming Non Items Inspected: Co nfo rm ing Non Items Inspected: Co nfo rm ing Non
Conforming Conforming Conforming
Placing Drawings Bar Length Column Ties Property
Appro ved x and Shape x Tied and Spaced NA
8 Sf Size x Proper B sr P lacem ant x Stirrup Spacing NA
. Stirrup Type
Bar Grade x Properly Tied x NA
Bars Clean x Dowel Bars in Place x Lapped Splices x
Form Clean x Pro per Bar Suppa rts x CornerBars x
Number of Bars x ProperCover x Mechanical Splices NA
Discrepancies / Comments: 1. Remove trash from placement area.
2. Adjust dowel bars.
3. Add chairs.
The discrepancies noted above were corrected at the time of inspection.
Technician: Jose Villanueva Started: 05:30am
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX) Altn: Mr. Paul Byrne
(1-ec copy)
1-ec Duke Construction, LP Altn: Mr. Jason Sulzener
1-cc City of Coppell Altn: Mr. Lee Stone
1-cc City of Coppell Altn: Mr. Larry Davis
Finished: 07:30am
Rone Engineering
ft~~
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/KW) Page 1 of 1